| Description | Low-Density Lipoprotein (LDL) in plasma is the main carrier of endogenous cholesterol. It is degraded and metabolized by binding to the LDL receptor (LDL-R) on cell membranes and serves as the primary vehicle for transporting cholesterol to peripheral tissues. However, when LDL, especially oxidized Low-Density Lipoprotein (LDL) in plasma is the main carrier of endogenous cholesterol. It is degraded and metabolized by binding to the LDL receptor (LDL-R) on cell membranes and serves as the primary vehicle for transporting cholesterol to peripheral tissues. However, when LDL, especially oxidized LDL (OX-LDL), is present in excess, the cholesterol it carries accumulates in the arterial walls, increasing the risk of atherosclerosis. Atherosclerosis is the pathological basis and risk factor for the majority of cardiovascular and cerebrovascular diseases.Detection Principle: In a cholesterol assay system containing cholesterol esterase (CHER) and cholesterol oxidase (CHOD), specific surfactants are added to selectively solubilize LDL-C for the determination of LDL-cholesterol. Other lipoproteins (HDL, VLDL, chylomicrons) do not react due to inhibition by the surfactants and sugar compounds, remaining in the form of lipoproteins in the reaction mixture. Based on this principle, LDL-cholesterol can be measured directly. Subsequently, esterase catalyzes the hydrolysis of cholesterol esters to generate Free Cholesterol (FC). FC is oxidized by cholesterol oxidase to produce 4-cholestenone and hydrogen peroxide. Hydrogen peroxide then reacts with 4-aminoantipyrine and other components to produce a red quinoneimine compound, which has a characteristic absorption peak at 546 nm. The LDL-C content is determined by measuring the absorbance at 546 nm.Component96TStorageReagent 118 mL2-8℃. Store in the dark.Reagent 26 mL2-8℃. Store in the dark.Standard1EA2-8℃. Store in the dark.Standard (Powder, 1 vial) Preparation:1. Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom of the tube.2. Add 0.1 mL of distilled water to dissolve. Use within one week. The prepared concentration is as indicated on the label.User-Prepared Instruments and Reagents:Mortar (Homogenizer), balance, ice box (ice maker), benchtop centrifuge, adjustable micropipettes, water bath (oven, incubator, metal bath), 96-well plate, centrifuge tubes, microplate reader, distilled water (deionized water or ultrapure water are acceptable), ethanol.Experimental ProcedureIt is recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure and to determine or adjust sample concentrations based on the preliminary results, preventing unnecessary waste of samples or reagents.1. Sample Extraction1.1 Tissue SamplesWeigh approximately 0.1 g of tissue sample and place it in a mortar. Add 1 mL of ethanol and homogenize in an ice bath. Centrifuge at 12,000 rpm, 4°C or room temperature for 10 minutes. Collect the supernatant for assay.Note: If increasing the sample amount, maintain a tissue mass (g) to ethanol volume (mL) ratio between 1:5 and 1:10.1.2 Liquid SamplesAssay clear liquid samples directly. If turbid, centrifuge and use the supernatant for assay.1.3 Bacterial/Cell SamplesCollect bacteria or cells into a centrifuge tube, centrifuge, and discard the supernatant. Add 1 mL of ethanol per approximately 5 million bacteria/cells. Disrupt the bacteria or cells by sonication in an ice bath (power 200W, pulse 3s on, 10s off, repeat 30 times). Centrifuge at 12,000 rpm, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.*Note: If increasing the sample amount, maintain a bacteria/cell count (10⁴) to ethanol volume (mL) ratio between 500:1 and 1000:1.*2. Assay Steps2.1 Preheat the microplate reader for 30 minutes (or wait for the instrument to complete its self-check). Set the wavelength to 546 nm.2.2 Thaw all reagents to room temperature (25°C). Add reagents sequentially to a 96-well plate as follows:Reagent (µL)Test TubeStandard Tube (once)Blank Tube (once)Sample2.5Standard2.5Distilled Water2.5Reagent 1180180180Mix well and incubate at 37°C for 5 minutes. Read the absorbance at 546 nm for each tube (A1 ).Reagent 2606060Mix well and incubate at 37°C for 10 minutes. Read the absorbance at 546 nm for each tube (A2 ). Calculate ΔA = A2 - A1 for each tube.Note:(1) If the A2 value for the Test Tube is greater than 1, dilute the sample with ethanol. The dilution factor (D) must be substituted into the calculation formula.(2) If ΔA for the Test Tube is lower than ΔA for the Blank Tube, consider increasing the sample volume V1 (e.g., increase the sample volume in the Test Tube and the water volume in the Blank Tube to 5 µL or more, keeping Reagents 1 and 2 volumes unchanged; for the Standard Tube, keep at 2.5 µL and add 2.5 µL distilled water to make up volume) or increasing the sample weight W (e.g., to 0.2 g or more). The changed V1 or W must then be substituted into the calculation formula.3. Calculation of Results3.1 Based on Sample MassDerived Formula:LDL-C (µmol/g weight) = (CStandard × V2 ) × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ (W × V1 ÷ V) × DSimplified Formula:LDL-C (µmol/g weight) = CStandard × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ W × D3.2 Based on Protein ContentDerived Formula:LDL-C (µmol/mg prot) = (CStandard × V2 ) × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ (Cpr × V1 ÷ V) × DSimplified Formula:LDL-C (µmol/mg prot) = CStandard × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ Cpr × D3.3 LDL-C Content in LiquidsDerived Formula:LDL-C (mmol/L) = (CStandard × V2 ) × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ V1 × DSimplified Formula:LDL-C (mmol/L) = CStandard × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) × D3.4 Based on Cell CountDerived Formula:LDL-C (nmol/10⁴ cells) = (CStandard × V2 ) × 10³ × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) ÷ (500 × V1 ÷ V) × DSimplified Formula:LDL-C (nmol/10⁴ cells) = 2 × CStandard × (ΔATest - ΔABlank ) ÷ (ΔAStandard - ΔABlank ) × DParameter Definitions:CStandard : Concentration as indicated on the label (mmol/L or µmol/mL)V1 : Volume of sample added (0.0025 mL)V: Volume of extraction buffer (ethanol) added (1 mL)V2 : Volume of standard added (0.0025 mL)D: Dilution factor (1 if not diluted)500: Number of cells (in units of 10⁴)W: Sample weight (g)Cpr: Protein concentration of the supernatant (mg/mL); Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) is recommended.Precautions1. It is recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure. Based on the preliminary results, determine or adjust sample concentrations to prevent unnecessary waste of samples or reagents.2. This product is for research use only. Not for use in clinical diagnosis. For your safety and health, please wear a lab coat and disposable gloves during operation... Read More | Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly Calcein AM /PI Double Staining Kitis utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains Calcein-AM and Propidium Iodide (PI) solutions, which stains viable and dead cells, respectively(Fig. 1). Calcein-AM, an acetoxymethyl ester of calcein, is highly lipophilic and cell membrane permeable. Though Calcein-AM itself is not a fluorescent molecule, the calcein generated from Calcein-AM by esterase in a viable cell emits a strong green fluorescence (excitationat 490 nm, emission at515 nm). Therefore, Calcein-AM only stains viable cells. On the other hand, PI, a nuclei staining dye, cannot pass through a viable cell membrane. It reaches the nucleus by passing through disordered areas of dead cell membrane, and intercalates with the DNA double helix of the cell to emit red fluorescence (excitation: 535 nm,emmision: 617 nm). Since both calcein and PI-DNA can be excited with 490 nm, simultaneous monitoring of viable and dead cells is possible with a fluorescence microscope. With 545 nm excitation, only dead cells can be observed (Fig. 1). Since optimal staining conditions differ from cell line to cell line, we recommend that a suitable concentration of PI and Calcein-AM be individually determined. Please note that PI is suspected to be highly carcinogenic;careful handling is required.Required Equipment and Materials:Microscope with 490 nm excitation filter and 530 nm emission filter;CO2incubator;10 µl and 200 µl adjustable pipettes, PBSSolution A (Calcein-AM);Solution B (PI) Storage Condition: -20oC ;Shipping Condition: blue ice.Application:Assay Procedure1)Add 2.5 µl Solution A and 12.5 µl Solution B to 5 ml PBS to prepare assay solution.*2)Wash the cell with PBS several times to remove residual esterase activity.3)Add 100uLof assay solution to200uL105~106CELLSsolution and incubate the mixture at 37oC for 15 min.4)Detect fluorescence using a fluorescence mircoscope with 490 nm excitationfor simultaneous monitoring of viable and dead cells.With 545 nm excitation, only dead cells can be observed.*The following steps may be necessary tooptimizethe suitable concentration of each reagent:1)Prepare dead cells by 10 min incubation in 0.1% saponin or 0.1-0.5% digitonin or by 30 min incubation in 70% ethanol.2)Stain dead cells with 0.1-10 µM PI solution to find a PI concentration that stains the nucleus only, not the cytosol.3)Stain dead cells with 0.1-10 µM Calcein-AM solution to find a Calcein-AM concentration that does not stain the cytosol. Then stainviable cells with that Calcein-AM solution to check whether the viable cell can be stained... Read More | Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and Product content:D665967Component200 TStorageD665967ABuffer PB120 mLRTD665967BBuffer PS60 mLRTD665967CBuffer PW (concentrate)25 mLRTD665967DBuffer EB30 mLRTD665967ESpin Columns DM with Collection Tubes200 EART Product Introduction: This reagent kit adopts a new silicon-based membrane technology and reagent formula. Through a rapid and simple three-step process of binding, washing, and elution, 100 bp-10 kb DNA fragments can be purified and recovered from PCR products or enzyme reaction solutions (enzyme cutting, linking, probe labeling, etc.). Each adsorption column can adsorb up to 10 kb of DNA fragments µ G DNA, while minimizing impurities such as primers, oligonucleotides, enzymes, etc. The purified and recovered DNA has high purity and concentration, good integrity, and high recovery rate, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagent: anhydrous ethanol.Preparation and important precautions before the experiment:1. All components can be stably stored in a dry, room temperature (15-30 ℃) environment for 1 year, and can be stored at 2-8 ℃ for longer periods of time. When the solution is stored at low temperature, it should be left at room temperature for a period of time before use, and then restored to room temperature before use.2. This reagent kit can selectively recover all DNA fragments from the solution. If you need to selectively recover specific fragments while removing other fragments of different sizes, please choose our company's gel recovery reagent kit.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in the Buffer PB. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. The recovery efficiency is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. All centrifugation steps can be performed at room temperature.Operation steps:1. Estimate the volume of DNA reaction solution, add 5 times the volume of Buffer PB, and mix thoroughly (without removing paraffin or mineral oil).Note: 1) If the DNA reaction system is 50 µ l (excluding paraffin oil volume), add 250 µ l Buffer PB.2) After adding Buffer PB, check the pH value of the solution. If the pH value is greater than 7.5, add 10-30 to it µ 3 M sodium acetate (pH 5.0) was used to adjust the pH value to 5-7.2. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.3. Add the solution obtained in step 1 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 1 minute, centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l, it can be added in batches.4. Add 500 µ l of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 30-60 seconds, discard the waste liquid in the collection tube, and place the adsorption column in the recovery tube.Note: If purified DNA is used for salt sensitivity experiments (such as flat end ligation experiments or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.5.13000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.). To ensure that downstream experiments are not affected by residual ethanol, it is recommended to open the cover of the adsorption column and place it at room temperature for a few minutes to thoroughly dry the residual ethanol in the adsorbent material at the bottom.6. Place the adsorption column into a new centrifuge tube (provided by oneself), add 30-50 µ l Buffer EB to the middle position of the adsorption membrane by hanging droplets, and let it stand at room temperature for 1 minute. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (the pH value of water can be adjusted to this range using NaOH).2) To improve the recovery of DNA, the solution obtained by centrifugation can be added back to the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.3) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency... Read More | Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize matrix effects, cross-reactions and unspecific binding in immunoassays like ELISA, Western blotting, Immunohistochemistry, protein arrays and immuno-PCR.The Effect Diluents, Animal-free are used alternatively to the standard sample or antibody dilution buffers: In ELISA for the dilution of specimen and detection antibodies. In Western Blotting for the dilution of primary and secondary antibodies. In Protein arrays for the dilution of specimen and detection antibodies. In immuno-PCR as a washing buffer.Three versions of the diluent are offered: Low, Medium and High for optimal discrimination between specific and unspecific reaction and for minimizing strong interference effects e.g., by RF (rheumatoid factors), HAMAs (human-a-mouse Abs) or by endogenous components that bind and mask the analyte.Composition & Properties The Effect Diluents, Animal free contain no animal components and are free of phosphates.Working Procedure 1.Mix thoroughly prior to use. 2.Dilution recommendations a.Dilute antibodies according to the instruction of the antibody b.Dilution of the specimen is recommended at 1:2 or higherTips & TricksEffect Diluents must not be considered as blocking buffers. Recommended blocking buffers are: Synthetic Blocking Buffer, ELISA (cat. no. S494401), Synthetic Blocking Buffer, Blotting (cat. no. S494457) and WellChampion (cat. no. W494467) for plate blocking and stabilization (preparation of pre-coated plates). Complex sample matrices, such as serum and plasma, may contain interfering factors that affect the ability of the assay to accurately quantify the target analyte. Strong interferences are often caused by RFs and HAMAs. This matrix effect can cause high background in the negative control or false negatives in the sample measurement. To reduce this effect the samples can be diluted in the Effect Diluents, Animalfree.Handling & Storage Store solution 2-8°C or -15 to -30°C (tolerates freezing and thawing cycles)... Read More | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More |