| Description | Triglycerides (TG), also known as triacylglycerols, are fat molecules formed from three long-chain fatty acids and glycerol. They are the most abundant lipids in the human body. Most tissues can utilize the breakdown products of triglycerides for energy. Simultaneously, tissues like the liver and Triglycerides (TG), also known as triacylglycerols, are fat molecules formed from three long-chain fatty acids and glycerol. They are the most abundant lipids in the human body. Most tissues can utilize the breakdown products of triglycerides for energy. Simultaneously, tissues like the liver and adipose tissue can synthesize triglycerides. The enzymatic method for measuring TG is commonly used in biochemical assays due to its characteristics: 1. High sensitivity, accuracy, and precision; 2. Use of mild reaction conditions; 3. Simple operation; 4. Suitable for semi-automatic biochemical analyzers.Detection Principle: Triglycerides are hydrolyzed by lipoprotein lipase (LPL) into glycerol and free fatty acids. Glycerol is then phosphorylated by glycerol kinase (GK) and adenosine triphosphate (ATP) to form glycerol-3-phosphate (G-3-P). G-3-P is subsequently oxidized by glycerol-3-phosphate oxidase (GPO), producing hydrogen peroxide. The hydrogen peroxide, in the presence of peroxidase (POD), 4-aminoantipyrine (4-AAP), and phenol (collectively known as PAP), reacts to form a red-colored quinoneimine dye (Trinder reaction). The quinoneimine dye has a maximum absorption at 510 nm. The absorbance is directly proportional to the triglyceride concentration in the sample and can be measured using a microplate reader between 500-520 nm.This kit is used for the quantitative determination of triglyceride content in serum, cells, tissues, and other samples from humans or animals. This kit is intended for research use only and is not suitable for clinical diagnosis or other purposes.Component100TStorageBuffer Solution24 mL2-8℃. Store in the dark.Enzyme Reagent6 mL2-8℃. Store in the dark.Glycerol Standard (1.7 mmol/L)1 mL2-8℃User-Prepared Instruments and ReagentsddH₂O, Physiological Saline or PBSCentrifuge tubes or small test tubes, Water bath or incubatorMicroplate reader, 96-well plate, Semi-automatic biochemical analyzerExperimental Procedure1. Sample Preparation1.1 Serum, Plasma, Cerebrospinal Fluid SamplesSerum or plasma separated from the test sample should not be hemolyzed. Assay directly. If the concentration exceeds the linear range, dilute with physiological saline before assaying.1.2 Cell Samples(1) Take an appropriate amount of cells (generally recommended >10⁶), centrifuge at 1000 g for 10 min, discard the supernatant, keep the pellet.(2) Wash the pellet 1-2 times with PBS or physiological saline, centrifuge at 1000 g for 10 min, discard the supernatant, keep the pellet.(3) Add 200-300 µL of PBS or physiological saline to homogenize. Sonicate the cells on ice (power 300W, pulse 3-5s, interval 30s, repeat 3-5 times). Alternatively, homogenize manually. Do not centrifuge the prepared homogenate. Alternatively, lyse with 1-2% Triton X-100 on ice for 30-60 min. Do not centrifuge the prepared lysate.1.3 Tissue SamplesAccurately weigh an appropriate amount of tissue sample. Add physiological saline or PBS at a mass (g) to volume (mL) ratio of 1:9. Homogenize manually or mechanically on ice. Centrifuge at 2500-3000 g for 10 min. Collect the supernatant for assay.2. Preparation of GPO-PAP Working SolutionBefore use, mix the Buffer Solution and Enzyme Reagent at a 4:1 volume ratio. Mix well. Store at 4°C.3. TG Assay Steps using Microplate Reader3.1 Add reagents sequentially to the 96-well plate according to the table below. Mix thoroughly and incubate at 37°C in a water bath or incubator for 10 minutes.Reagent (µL)Blank WellStandard WellTest WellddH2O2.5//Glycerol Standard (1.7 mmol/L)/2.5/Test Sample//2.5GPO-PAP Working Solution2502502503.2 Measure the absorbance between 500-520 nm using the microplate reader. Zero the instrument with the blank well, then read the absorbance of the standard well and all test wells.4. TG Assay Steps using Semi-Automatic Biochemical Analyzer4.1 Instrument Parameter Settings:WavelengthTemperatureDelay TimeMeasurement TimeReagent BlankReaction TypeAspiration Volume510-550nm37℃2s2sYesEndpoint800µL4.2 Add reagents sequentially to tubes according to the table below. Mix thoroughly and incubate at 37°C in a water bath for 10 minutes.Reagent (µL)Blank TubeStandard TubeTest TubeddH2O10//Glycerol Standard (1.7 mmol/L)/10/Test Sample//10GPO-PAP Working Solution1000100010004.3 Zero the instrument with the blank tube, then read the absorbance of the standard tube and all test tubes.5. Calculation Formula5.1 For serum, plasma, and other liquid samples (Blank zeroed):TG (mmol/L) = (Absorbance of Test Well/Tube / Absorbance of Standard Well/Tube) × 1.7 mmol/L5.2 For cell, tissue, and other samples (Blank zeroed):TG (mmol/g prot) = (Absorbance of Test Well/Tube / Absorbance of Standard Well/Tube) × 1.7 mmol/L / Sample Protein Concentration (mg/mL)Reference Interval (Healthy Adults)Desirable range: < 1.7 mmol/L (< 150 mg/dL)Borderline high: 1.7 – 2.25 mmol/L (150 – 199 mg/dL)High: 2.26 – 5.64 mmol/L (200 – 499 mg/dL)Very high: ≥ 5.65 mmol/L (≥ 500 mg/dL)Precautions1. Avoid repeated freeze-thaw cycles for the low-temperature reagents mentioned above to prevent inactivation or decreased efficiency.2. The GPO-PAP Working Solution should be prepared immediately before use and is not suitable for long-term storage at 4°C.3. This method can be directly used to detect TG content in cerebrospinal fluid but cannot directly detect TG in urine, as untreated urine contains reducing substances that interfere with the peroxidase reaction.4. If test samples cannot be assayed immediately, they should be stored at 2-8°C and are stable for 3 days.5. The linear range of this method is up to 9.0 mmol/L. If the sample TG concentration is too high, results may be falsely low. Dilute the sample with physiological saline and re-assay, multiplying the result by the dilution factor.6. The working reagent should be protected from contamination by substances like glucose and cholesterol.7. The reagent is susceptible to oxidation by air, turning red. A blank measurement is necessary.8. For your safety and health, please wear a lab coat and disposable gloves during operation.9.Use the reagents as soon as possible after opening to prevent affecting subsequent experimental results... Read More | DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise. Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 1 µm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to develop multifunctional particles for diverse applications, including dual labelling.Binding Capacity and Dispersity:Binding Capacity:> 20 µg IgG/mgMonodispersity:> 90% (by light microscopy determination)Particle based immunoassays, bioseparations and immunoprecipitation... Read More | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Vitamins Kit is a multivitamin mix comprising biotin, folic acid, vitamin B6, riboflavin, thiamine, D-pantothenic acid and niacinamide.Vitamins Kit has been used as a vitamin supplement in the minimal medium for conidia spores and vegetative cultures |