| Description | Triglycerides (TG), also known as triacylglycerols, are fat molecules formed from three long-chain fatty acids and glycerol. They are the most abundant lipids in the human body. Most tissues can utilize the breakdown products of triglycerides for energy. Simultaneously, tissues like the liver and Triglycerides (TG), also known as triacylglycerols, are fat molecules formed from three long-chain fatty acids and glycerol. They are the most abundant lipids in the human body. Most tissues can utilize the breakdown products of triglycerides for energy. Simultaneously, tissues like the liver and adipose tissue can synthesize triglycerides. The enzymatic method for measuring TG is commonly used in biochemical assays due to its characteristics: 1. High sensitivity, accuracy, and precision; 2. Use of mild reaction conditions; 3. Simple operation; 4. Suitable for semi-automatic biochemical analyzers.Detection Principle: Triglycerides are hydrolyzed by lipoprotein lipase (LPL) into glycerol and free fatty acids. Glycerol is then phosphorylated by glycerol kinase (GK) and adenosine triphosphate (ATP) to form glycerol-3-phosphate (G-3-P). G-3-P is subsequently oxidized by glycerol-3-phosphate oxidase (GPO), producing hydrogen peroxide. The hydrogen peroxide, in the presence of peroxidase (POD), 4-aminoantipyrine (4-AAP), and phenol (collectively known as PAP), reacts to form a red-colored quinoneimine dye (Trinder reaction). The quinoneimine dye has a maximum absorption at 510 nm. The absorbance is directly proportional to the triglyceride concentration in the sample and can be measured using a microplate reader between 500-520 nm.This kit is used for the quantitative determination of triglyceride content in serum, cells, tissues, and other samples from humans or animals. This kit is intended for research use only and is not suitable for clinical diagnosis or other purposes.Component100TStorageBuffer Solution24 mL2-8℃. Store in the dark.Enzyme Reagent6 mL2-8℃. Store in the dark.Glycerol Standard (1.7 mmol/L)1 mL2-8℃User-Prepared Instruments and ReagentsddH₂O, Physiological Saline or PBSCentrifuge tubes or small test tubes, Water bath or incubatorMicroplate reader, 96-well plate, Semi-automatic biochemical analyzerExperimental Procedure1. Sample Preparation1.1 Serum, Plasma, Cerebrospinal Fluid SamplesSerum or plasma separated from the test sample should not be hemolyzed. Assay directly. If the concentration exceeds the linear range, dilute with physiological saline before assaying.1.2 Cell Samples(1) Take an appropriate amount of cells (generally recommended >10⁶), centrifuge at 1000 g for 10 min, discard the supernatant, keep the pellet.(2) Wash the pellet 1-2 times with PBS or physiological saline, centrifuge at 1000 g for 10 min, discard the supernatant, keep the pellet.(3) Add 200-300 µL of PBS or physiological saline to homogenize. Sonicate the cells on ice (power 300W, pulse 3-5s, interval 30s, repeat 3-5 times). Alternatively, homogenize manually. Do not centrifuge the prepared homogenate. Alternatively, lyse with 1-2% Triton X-100 on ice for 30-60 min. Do not centrifuge the prepared lysate.1.3 Tissue SamplesAccurately weigh an appropriate amount of tissue sample. Add physiological saline or PBS at a mass (g) to volume (mL) ratio of 1:9. Homogenize manually or mechanically on ice. Centrifuge at 2500-3000 g for 10 min. Collect the supernatant for assay.2. Preparation of GPO-PAP Working SolutionBefore use, mix the Buffer Solution and Enzyme Reagent at a 4:1 volume ratio. Mix well. Store at 4°C.3. TG Assay Steps using Microplate Reader3.1 Add reagents sequentially to the 96-well plate according to the table below. Mix thoroughly and incubate at 37°C in a water bath or incubator for 10 minutes.Reagent (µL)Blank WellStandard WellTest WellddH2O2.5//Glycerol Standard (1.7 mmol/L)/2.5/Test Sample//2.5GPO-PAP Working Solution2502502503.2 Measure the absorbance between 500-520 nm using the microplate reader. Zero the instrument with the blank well, then read the absorbance of the standard well and all test wells.4. TG Assay Steps using Semi-Automatic Biochemical Analyzer4.1 Instrument Parameter Settings:WavelengthTemperatureDelay TimeMeasurement TimeReagent BlankReaction TypeAspiration Volume510-550nm37℃2s2sYesEndpoint800µL4.2 Add reagents sequentially to tubes according to the table below. Mix thoroughly and incubate at 37°C in a water bath for 10 minutes.Reagent (µL)Blank TubeStandard TubeTest TubeddH2O10//Glycerol Standard (1.7 mmol/L)/10/Test Sample//10GPO-PAP Working Solution1000100010004.3 Zero the instrument with the blank tube, then read the absorbance of the standard tube and all test tubes.5. Calculation Formula5.1 For serum, plasma, and other liquid samples (Blank zeroed):TG (mmol/L) = (Absorbance of Test Well/Tube / Absorbance of Standard Well/Tube) × 1.7 mmol/L5.2 For cell, tissue, and other samples (Blank zeroed):TG (mmol/g prot) = (Absorbance of Test Well/Tube / Absorbance of Standard Well/Tube) × 1.7 mmol/L / Sample Protein Concentration (mg/mL)Reference Interval (Healthy Adults)Desirable range: < 1.7 mmol/L (< 150 mg/dL)Borderline high: 1.7 – 2.25 mmol/L (150 – 199 mg/dL)High: 2.26 – 5.64 mmol/L (200 – 499 mg/dL)Very high: ≥ 5.65 mmol/L (≥ 500 mg/dL)Precautions1. Avoid repeated freeze-thaw cycles for the low-temperature reagents mentioned above to prevent inactivation or decreased efficiency.2. The GPO-PAP Working Solution should be prepared immediately before use and is not suitable for long-term storage at 4°C.3. This method can be directly used to detect TG content in cerebrospinal fluid but cannot directly detect TG in urine, as untreated urine contains reducing substances that interfere with the peroxidase reaction.4. If test samples cannot be assayed immediately, they should be stored at 2-8°C and are stable for 3 days.5. The linear range of this method is up to 9.0 mmol/L. If the sample TG concentration is too high, results may be falsely low. Dilute the sample with physiological saline and re-assay, multiplying the result by the dilution factor.6. The working reagent should be protected from contamination by substances like glucose and cholesterol.7. The reagent is susceptible to oxidation by air, turning red. A blank measurement is necessary.8. For your safety and health, please wear a lab coat and disposable gloves during operation.9.Use the reagents as soon as possible after opening to prevent affecting subsequent experimental results... Read More | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | DescriptioniPE-Quick Kit is intended for the advanced confirmation of target protein expression utilizingE. Coliextract before the use of theiPE kit (Prod. No. 905089) | The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This product provides a rapid, sensitive and stable detection method for the expression of Renilla luciferase reporter gene in mammalian cells. Product characteristic:1.Rapid : Cell lysis was completed within 10-15 min ;2.Convenience : The reagent is easy to prepare, and the sample detection steps are simple;Instruction:1. Cell lysis ( 1 ) Remove the culture medium and gently wash with PBS ( adherent cells can be directly performed this operation, suspension cells should be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products after full pyrolysis were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was moved into a new EP tube for subsequent detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C into renilla luciferase working solution with component B, and the dilution method is to add 1 µL C component to 49 µL B component. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) The cell lysis products were added to the measuring tube according to the volume of 20 ~ 100 µL ( keep the same amount of samples each time ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL renilla luciferase working solution was added to determine the RLU ( Relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). Note : The renilla luciferase working solution cannot be stored for a long time. It is now ready for use and is used once. Component:RenillaLuciferase Lysis Buffer;RenillaLuciferase Assay Buffer;CoelenterazineMatters needing attention:Scope of application: Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.Due to the influence of temperature on the enzyme reaction, the sample and reagent should be measured after reaching room temperature. 3.The strongest wavelength of bioluminescence catalyzed by renilla luciferase is 480 nm, in order to prevent interference between holes, it is recommended to use white opaque orifice plate ;4. B component is recommended to carry out small batch packing according to the experimental requirements ; 5.It is recommended to use it now to avoid repeated freezing and thawing ; 6.For your safety and health, please wear experimental clothes and wear disposable gloves. Scope of application:Study on gene expression regulation and promoter... Read More |