| Description | Inquire | Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Instruction: Experimental materials ( self-provided ):①cell lines or other cell samples ( self-prepared ) ;②This kit ; ③ trypsin ( self-prepared ) ;④ Cell culture medium containing FBS ( self-prepared ) ; Experimental procedure: 1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. ( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. ( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 2.Staining : 4 µL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.Scope of application:Cell cycle detection... Read More | DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the DescriptionCobalt is a transition metal that serves as a trace dietary mineral for all multicellular organisms. Cobalt is an important cofactor for the Vitamin B12class of compounds where it occupies the center of the vitamin B12corrin ring. Cobalt can also be coordinated in the active site of the non-corrin containing metalloenzyme methionine aminopeptidase.Suitability: Suitable for quantitating cobalt concentrations in a variety of samplesPrinciple: The Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference from the metal ions Fe2+, Cu2+, Ni2+, Zn2+, and Mn2+is <10% at this wavelength. This assay gives a linear range of 10-50 nmoles of cobalt.}Preparation instructionsSuitable for quantitating cobalt concentrations in a variety of samplesPrincipleThe Cobalt Assay kit provides a simple and direct procedure for measuring cobalt in a variety of samples. In this assay, cobalt reacts with 2-mercaptoethanol under basic conditions to form a complex with a strong absorbance at 475 nm. Interference... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export |