| Description | Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic beads Max200 µL500 µL4℃M1456374 BIncubation Buffer I4.8 mL12 mLRTM1456374 CIncubation Buffer II6 mL15 mLRTM1456374 DWashing Buffer6 mL15 mLRTM1456374 ELysis Buffer0.6 mL1.5 mL-20℃. Store in the dark.M1456374 FBalance Buffer2.8mL7 mL4℃M1456374 GDigest Buffer16 µL40 µL-20℃M1456374 HStop Buffer300 µL750 µLRTM1456374 IWash Buffer I4 mL10 mLRTM1456374 JWash Buffer II2.4 mL6 mLRTM1456374 KWash Buffer III2.4 mL6 mLRTM1456374 LElution Buffer4.8 mL12 mLRT. Store in the dark.M1456374 MLoading Buffer120 µL300 µLRTM1456374 NTip pillar10T25TRTOperating Procedure: 1.Centrifuge the plasma sample (3000g, 10min), and take the supernatant for later use (if storage is required, store it at -80°C for long-term preservation to avoid repeated freezing and thawing).2.Take 50-100µL of centrifuged plasma, add 400µL of Incubation buffer I, then add 18µL of Magnetic beads, vortex to mix, and incubate at room temperature on a shaking mixer for 1 hour.3.After incubation, use a magnetic rack to magnetically separate for 3min, and discard the supernatant.4.Remove the EP tube, add 500µL of Incubation buffer II, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.5.Remove the EP tube, add 500µL of Washing Buffer, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.6.Remove the EP tube, add 50µL of Lysis Buffer to resuspend the beads, place in a water bath at 95°C for 10min, then take it out and cool to room temperature.7.Add 225µL of Balance buffer to the EP tube that has cooled to room temperature.8.Add 1µL of Digest buffer to the sample, and perform enzymatic digestion with shaking in a metal bath at 37°C and 1200rpm for 3-16h.9.After enzymatic digestion, take out the EP tube, add 25µL of Stop buffer to the sample, and vortex to mix.10.Add 320µL of Wash buffer I, shake vigorously for 3min, centrifuge at 15000rpm for 3min, and remove the upper liquid.11.Transfer the lower layer sample into the Tip column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down. If the liquid flow rate is slow, the rotation speed can be appropriately increased.12.Add 200µL of Wash buffer II (shake for 10-20s before use) to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.13.Add 200µL of Wash buffer III to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.14.Put the desalting column into a new EP tube, add 200µL of Elution buffer to the desalting column, centrifuge at 2000rpm for 3-5min until all the liquid is centrifuged down.15.Repeat the previous step, collect the eluates from both times, and freeze-dry them.16.Add 10µL of Loading buffer, vortex vigorously for 3min, centrifuge at 2000g for 10min, take an appropriate amount of sample for mass spectrometry detection. Taking the HF-X instrument as an example, 0.5-1µg of sample is sufficient for loading. Automated Operation Process:It is compatible with mass spectrometry proteomics pretreatment workstations, enabling one-stop processing from plasma to peptides. This eliminates manual operation errors, improves the reproducibility of sample preparation workflows, and provides high precision and reliability for various laboratory procedures... Read More | Inquire | Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products IntroductionThis product is mainly used for PCR using bisulfite-treated DNA as template, in which SuperFastStar DNA Polymerase is a new high-efficiency hot-start enzyme modified by bis-monoclonal antibody, which is completely blocked at room temperature, thus effectively avoiding non-specific amplification caused by the non-specific binding of the primer to the template or the primer dimerization under the condition of room temperature. The optimized FastStar Probe Buffer (for bisDNA) contains PCR Buffer, dNTPs and Mg2+, etc., which is easy to use as customers only need to add templates, primers and probes.caveat1 Before use, please mix the product gently by turning it up and down after it has been completely melted and centrifuged briefly.2. Avoid repeated freezing and thawing of the product, which may degrade its performance. This product can be stored at -20℃ for a long period of time, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.Usage The following examples are conventional PCR reaction systems and conditions, which should be improved and optimized according to the template, primer structure and target fragment size.1.PCR reaction system Note: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.2)The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3)Usually the amount of DNA template is 10-100 ng of genomic DNA or 1-10 ng of cDNA as a reference. Since the templates of different species contain different copy numbers of the target gene, the templates can be diluted in gradients to determine the optimal amount of template to use.2.PCR reaction conditionsNote: 1) The initial denaturation of this product at 95°C for 30s is sufficient for enzyme activation; complex templates can be extended to 3min denaturation.(2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | Inquire | Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×Products contentN665737Component24 T96 TStorageN665737ATPS V50 168 µL672 µL-20℃. Avoid freeze/thaw cycle.N665737B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665737CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665737D2×PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input is 5 ng. We also have transposase library construction kits for 50 ng and 1 ng of human genomic DNA starting, in order to get a higher quality library, it is recommended to use different kits for different starting amount of DNA. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with a starting template DNA input of 5 ng, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows: inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recovery Library DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More |