| Description | Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic beads Max200 µL500 µL4℃M1456374 BIncubation Buffer I4.8 mL12 mLRTM1456374 CIncubation Buffer II6 mL15 mLRTM1456374 DWashing Buffer6 mL15 mLRTM1456374 ELysis Buffer0.6 mL1.5 mL-20℃. Store in the dark.M1456374 FBalance Buffer2.8mL7 mL4℃M1456374 GDigest Buffer16 µL40 µL-20℃M1456374 HStop Buffer300 µL750 µLRTM1456374 IWash Buffer I4 mL10 mLRTM1456374 JWash Buffer II2.4 mL6 mLRTM1456374 KWash Buffer III2.4 mL6 mLRTM1456374 LElution Buffer4.8 mL12 mLRT. Store in the dark.M1456374 MLoading Buffer120 µL300 µLRTM1456374 NTip pillar10T25TRTOperating Procedure: 1.Centrifuge the plasma sample (3000g, 10min), and take the supernatant for later use (if storage is required, store it at -80°C for long-term preservation to avoid repeated freezing and thawing).2.Take 50-100µL of centrifuged plasma, add 400µL of Incubation buffer I, then add 18µL of Magnetic beads, vortex to mix, and incubate at room temperature on a shaking mixer for 1 hour.3.After incubation, use a magnetic rack to magnetically separate for 3min, and discard the supernatant.4.Remove the EP tube, add 500µL of Incubation buffer II, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.5.Remove the EP tube, add 500µL of Washing Buffer, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.6.Remove the EP tube, add 50µL of Lysis Buffer to resuspend the beads, place in a water bath at 95°C for 10min, then take it out and cool to room temperature.7.Add 225µL of Balance buffer to the EP tube that has cooled to room temperature.8.Add 1µL of Digest buffer to the sample, and perform enzymatic digestion with shaking in a metal bath at 37°C and 1200rpm for 3-16h.9.After enzymatic digestion, take out the EP tube, add 25µL of Stop buffer to the sample, and vortex to mix.10.Add 320µL of Wash buffer I, shake vigorously for 3min, centrifuge at 15000rpm for 3min, and remove the upper liquid.11.Transfer the lower layer sample into the Tip column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down. If the liquid flow rate is slow, the rotation speed can be appropriately increased.12.Add 200µL of Wash buffer II (shake for 10-20s before use) to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.13.Add 200µL of Wash buffer III to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.14.Put the desalting column into a new EP tube, add 200µL of Elution buffer to the desalting column, centrifuge at 2000rpm for 3-5min until all the liquid is centrifuged down.15.Repeat the previous step, collect the eluates from both times, and freeze-dry them.16.Add 10µL of Loading buffer, vortex vigorously for 3min, centrifuge at 2000g for 10min, take an appropriate amount of sample for mass spectrometry detection. Taking the HF-X instrument as an example, 0.5-1µg of sample is sufficient for loading. Automated Operation Process:It is compatible with mass spectrometry proteomics pretreatment workstations, enabling one-stop processing from plasma to peptides. This eliminates manual operation errors, improves the reproducibility of sample preparation workflows, and provides high precision and reliability for various laboratory procedures... Read More | Inquire | DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) quantify all the biochemicals in the sample relative to their counterparts in the Internal Standard, b) suppression-correct each compound and c) normalize sample to sample variances; and (2) injecting the same well characterized Long-Term Reference Standard (WORKFLOW-B) to create a daily retention time (RT) library of all compounds to be found in the Internal Standard for reproducible ID, and to measure day-to-day (QA/QC) to assure reproducible instrument performance. The system is completely automated using IROA ClusterFinder™software.IROA TruQuant IQQ Workflow Kit contains the materials and tools for the analysis of 90 experimental samples. The kit is intended to be used for mass spectrometry metabolomics applications... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More | Inquire |