| Description | Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic Product Introduction:This kit is used to enrich low-abundance proteins in plasma samples and rapidly prepare proteomic samples, and the processed samples can be used for subsequent mass spectrometry detection.Product Components and Storage Conditions:M1456374Component10T25TStorageM1456374 AMagnetic beads Max200 µL500 µL4℃M1456374 BIncubation Buffer I4.8 mL12 mLRTM1456374 CIncubation Buffer II6 mL15 mLRTM1456374 DWashing Buffer6 mL15 mLRTM1456374 ELysis Buffer0.6 mL1.5 mL-20℃. Store in the dark.M1456374 FBalance Buffer2.8mL7 mL4℃M1456374 GDigest Buffer16 µL40 µL-20℃M1456374 HStop Buffer300 µL750 µLRTM1456374 IWash Buffer I4 mL10 mLRTM1456374 JWash Buffer II2.4 mL6 mLRTM1456374 KWash Buffer III2.4 mL6 mLRTM1456374 LElution Buffer4.8 mL12 mLRT. Store in the dark.M1456374 MLoading Buffer120 µL300 µLRTM1456374 NTip pillar10T25TRTOperating Procedure: 1.Centrifuge the plasma sample (3000g, 10min), and take the supernatant for later use (if storage is required, store it at -80°C for long-term preservation to avoid repeated freezing and thawing).2.Take 50-100µL of centrifuged plasma, add 400µL of Incubation buffer I, then add 18µL of Magnetic beads, vortex to mix, and incubate at room temperature on a shaking mixer for 1 hour.3.After incubation, use a magnetic rack to magnetically separate for 3min, and discard the supernatant.4.Remove the EP tube, add 500µL of Incubation buffer II, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.5.Remove the EP tube, add 500µL of Washing Buffer, gently invert up and down to mix several times, magnetically separate for 3min, and discard the supernatant.6.Remove the EP tube, add 50µL of Lysis Buffer to resuspend the beads, place in a water bath at 95°C for 10min, then take it out and cool to room temperature.7.Add 225µL of Balance buffer to the EP tube that has cooled to room temperature.8.Add 1µL of Digest buffer to the sample, and perform enzymatic digestion with shaking in a metal bath at 37°C and 1200rpm for 3-16h.9.After enzymatic digestion, take out the EP tube, add 25µL of Stop buffer to the sample, and vortex to mix.10.Add 320µL of Wash buffer I, shake vigorously for 3min, centrifuge at 15000rpm for 3min, and remove the upper liquid.11.Transfer the lower layer sample into the Tip column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down. If the liquid flow rate is slow, the rotation speed can be appropriately increased.12.Add 200µL of Wash buffer II (shake for 10-20s before use) to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.13.Add 200µL of Wash buffer III to the desalting column, centrifuge at 2500rpm for 3-5min until all the liquid is centrifuged down.14.Put the desalting column into a new EP tube, add 200µL of Elution buffer to the desalting column, centrifuge at 2000rpm for 3-5min until all the liquid is centrifuged down.15.Repeat the previous step, collect the eluates from both times, and freeze-dry them.16.Add 10µL of Loading buffer, vortex vigorously for 3min, centrifuge at 2000g for 10min, take an appropriate amount of sample for mass spectrometry detection. Taking the HF-X instrument as an example, 0.5-1µg of sample is sufficient for loading. Automated Operation Process:It is compatible with mass spectrometry proteomics pretreatment workstations, enabling one-stop processing from plasma to peptides. This eliminates manual operation errors, improves the reproducibility of sample preparation workflows, and provides high precision and reliability for various laboratory procedures... Read More | Inquire | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export |