| Description | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.Experimental principle:This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.Kit composition:130times concentrated washing solution20ml×1 bottle8.1Standard S1(80µg/L)0.5ml×1bottle2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40µg/L)0.5ml×1bottle3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20µg/L)0.5ml×1bottle4Color reagent A solution6ml×1 bottle8.4Standard S4(10µg/L)0.5ml×1bottle5Color developer B solution6ml×1 bottle8.5Standard S5(5µg/L)0.5ml×1bottle6Stop solution6ml×1 bottle9Instructions1 copy7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheetsSpecimen requirements:1. Specimen processing:(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).Operation steps:1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested µ l. Then add 10 more samples to be tested µ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.2. Enzyme addition: Add 50 enzyme labeled reagents to each well µ l. Excluding blank holes.3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.6. Color development: Add color development agent A50 to each well first µ l. Add color developer B50 again µ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes7. Termination: Add 50% termination fluid to each hole µ l. Terminate the reaction (at this point, the blue color immediately turns yellow).8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.Calculation:Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.Notes:1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).5. The sealing film is only for one-time use to avoid cross contamination.6. Please store the substrate in dark.7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader8. All samples, washing liquids, and various waste should be treated as infectious substances.9. The components of this reagent with different batch numbers shall not be mixed.Detection range:two µ G/L-90 µ G/L... Read More | Product content:M665754Component25 TStorageM665754ATris-HCl, 1 mM, PH 8.01 mL-20℃. Avoid freeze/thaw cycleM665754BE. coli Poly(A) Polymerase, 5 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754C10×Poly(A) Polymerase Buffer80 µL-20℃. Avoid freeze/thaw Product content:M665754Component25 TStorageM665754ATris-HCl, 1 mM, PH 8.01 mL-20℃. Avoid freeze/thaw cycleM665754BE. coli Poly(A) Polymerase, 5 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754C10×Poly(A) Polymerase Buffer80 µL-20℃. Avoid freeze/thaw cycleM665754DATP, 10 mM15 µL-20℃. Avoid freeze/thaw cycleM665754ERT Primer, 25 µM90 µL-20℃. Avoid freeze/thaw cycleM665754F5×SuperRT Buffer120 µL-20℃. Avoid freeze/thaw cycleM665754GUltraPure dNTP Mix, 10 mM each30 µL-20℃. Avoid freeze/thaw cycleM665754HSuperRT, 200 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754IRNase-Free Water1 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kit uses the method of adding a poly (A) tail at the 3 'end of miRNA to give miRNA a Poly (A) tail, followed by reverse transcription using Oligo (dT) - Universal tag universal reverse transcription primers to synthesize the first stranded cDNA corresponding to miRNA. The miRNA cDNA first strand synthesis kit contains all the reagents required for the miRNA 3 'end Poly (A) tail modification process and the reverse transcription process after modification. This kit has a very high Poly (A) modification and reverse transcription efficiency, which can range from 1 ng-2 µ The first strand of cDNA corresponding to miRNA was effectively obtained from the total RNA of g. And the operation is simple and fast, which can be used to simultaneously detect multiple miRNAs from a synthesized cDNA reaction. This not only reduces errors and saves samples, but also achieves high-throughput detection.Note: This kit must be used in conjunction with the miRNA fluorescence quantitative detection kit.Self prepared experimental materials: 1 ng-2 µ Total RNA of g, or 0.1 ng-1 µ Small molecule RNA of g.Notes:To prevent RNase pollution, attention should be paid to the following aspects:1. Use plastic products and gun heads without RNase to avoid cross contamination.2. Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use. Plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3. The solution should be prepared using water without RNase.4. Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.Usage:A. The process of miRNA adding Poly (A) tail:1.based on the amount of RNA used, dilute the total RNA of 10 mM ATP with 1 mM Tris (pH 8.0) according to the following formula: ATP dilution coefficient=5000/__ ngExample: If the initial amount of total RNA is 100 ng, then the ATP dilution coefficient is 5000/100=50. About to dilute ATP 50 times (1 µ 10 mM ATP plus 49 for l µ 1 mM Tris at pH 8.0.2. Add the following reagents to the pre cooled RNase free reaction tube in the ice bath to a total volume of 25 µ L. reagent 25 µlReaction system final concentration total RNA* X µl Up to 2 µg 10×Poly(A) Polymerase Buffer 2.5 µl 1× Diluted ATP in step "1" 1 µl / E. coli Poly(A) Polymerase, 5U/µl 0.5 µl 2.5 U RNase-Free Water up to 25 µl /*The total RNA used in the reaction must contain small molecule RNA.This process can also directly use small molecule RNA (recommended dosage of 2-5) µ L. Please determine the amount added based on the abundance of the target miRNA.3. Gently mix the above reaction solution and briefly centrifuge to collect the liquid at the bottom of the tube. Incubate at 37 ℃ for 15 minutes. After this process is completed, immediately proceed with the synthesis of the first strand cDNA or temporarily store it at -20 ℃. If long-term storage is required, it is recommended to store at -80 ℃.B. The process of synthesizing the first strand of modified miRNA cDNA:1. Add the reagents in the table below to the pre cooled RNase free reaction tube in the ice bath until the final volume reaches 20µl: reagent 20 µlReaction system The above Poly (A) reaction solution 4 µl UltraPure dNTP Mix ,10 mM each 1 µl RT Primer ,25 µM 3 µl 5×SuperRT Buffer 4 µl SuperRT ,200 U/µl 0.5 µl RNase-Free Water 7.5 µl2. Gently mix the above reaction solution and briefly centrifuge to collect the liquid at the bottom of the tube. Incubate at 42 ℃ for 50 minutes.3.85 ℃ for 5 minutes and terminate the reaction. The synthesized cDNA reaction solution can be directly used for fluorescence quantitative detection experiments or stored at -20 ℃ for future use... Read More |