| Description | Chloroplast 3-phosphoglycerate kinase (PGK) is a key enzyme in the Calvin cycle. Detection Principle: Chloroplast 3-phosphoglycerate kinase catalyzes the reaction of 3-phosphoglyceric acid and ATP to produce 1,3-bisphosphoglyceric acid. The latter, under the action of glyceraldehyde-3-phosphate Chloroplast 3-phosphoglycerate kinase (PGK) is a key enzyme in the Calvin cycle. Detection Principle: Chloroplast 3-phosphoglycerate kinase catalyzes the reaction of 3-phosphoglyceric acid and ATP to produce 1,3-bisphosphoglyceric acid. The latter, under the action of glyceraldehyde-3-phosphate dehydrogenase and NADH, produces glyceraldehyde-3-phosphate and NAD⁺. The enzyme activity of 3-phosphoglycerate kinase is determined by measuring the decrease in NADH.Component96TStorageExtraction Buffer 1100 mL2-8℃Extraction Buffer 2100 mL2-8℃Reagent 11EA-20℃. Store in the dark.Reagent 23EA2-8℃Reagent 31EA-20℃Reagent 435 mL2-8℃Reagent 51EA-20℃Reagent Preparation:Reagent 1 (Powder, 1 vial):Before opening, ensure the powder is at the bottom (can be flicked manually).Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.Reagent 2 (Powder, 3 vials):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 0.4 mL of distilled water per vial to dissolve. Use after preparation.Unused dissolved reagent can be aliquoted and stored at -20°C. Avoid repeated freeze-thaw cycles. Use within 3 days.Reagent 3 (Powder, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.Reagent 5 (Powder, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.User-Prepared Instruments and MaterialsMortar (Homogenizer), Ice box (Ice maker), Benchtop centrifuge, Adjustable micropipettes, Water bath (Oven, Incubator, Metal bath), 96-well plate, Centrifuge tubes, Microplate reader, Vortex mixer/shaker, Distilled water (Deionized water or Ultrapure water are acceptable).Experimental ProcedureIt is recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure and to determine or adjust sample concentrations based on the preliminary results, preventing unnecessary waste of samples or reagents.1. Sample Extraction (Chloroplast Isolation)Weigh approximately 0.1 g of plant tissue sample. Add 1 mL of Extraction Buffer 1 and homogenize rapidly in an ice bath. Centrifuge at 1,600 rpm, 4°C for 5 minutes. Discard the pellet. Take the supernatant and centrifuge again at 5,000 rpm, 4°C for 15 minutes. Discard the supernatant and keep the pellet. Add 1 mL of Extraction Buffer 2 to the pellet. Vortex vigorously for 15 seconds. Place on ice (or in a refrigerator) and incubate at 4°C for 15 minutes. Centrifuge at 13,000 rpm, 4°C for 5 minutes. Collect the supernatant for assaying the chloroplast 3-phosphoglycerate kinase (PGK) enzyme activity.Important: The entire chloroplast extraction process must be maintained at 4°C.Note: If increasing the sample amount, maintain a tissue mass (g) to Extraction Buffer volume (mL) ratio between 1:5 and 1:10.2. Assay Steps2.1 Preheat the microplate reader for 30 minutes. Set the wavelength to 340 nm and the temperature to 25°C.2.2 Thaw all reagents to room temperature (25°C).2.3 Add reagents sequentially to a 96-well plate:ReagentTest Well (µL)Sample20Reagent 110Reagent 210Reagent 310Reagent 4140Mix well and incubate at room temperature (25°C) for 10 minutes.Reagent 510Mix gently. Under room temperature (25°C) conditions, read the absorbance at 340 nm at 30 seconds (A₁) and then again after 10 minutes (A₂). Calculate ΔA = A₁ - A₂.注:Notes:(1) If ΔA is close to zero, the reaction time can be appropriately extended to 20 minutes before reading A₂. If the reaction time is changed, the new time (T) must be substituted into the calculation formula. Alternatively, the sample volume can be increased (e.g., to 40 µL, with a corresponding decrease in Reagent 4 volume); the new sample volume (V₁) must then be substituted into the calculation formula.(2) If the decrease trend is unstable, read the absorbance every 20 seconds and select a linearly decreasing time period for calculation. The corresponding A values for this period should be used to calculate ΔA and substituted into the formula.(3) If the initial absorbance A₁ is too high (e.g., >2, as in dark green plant leaves with high pigment content), consider appropriately reducing the sample volume; the new sample volume (V₁) must be substituted into the calculation formula. Alternatively, add a small amount of activated carbon to the sample, mix, let stand for 5 minutes, then centrifuge at 12,000 rpm, 4°C for 10 minutes, and use the supernatant for assay.(4) If ΔA is greater than 0.5, reduce the reaction time (e.g., to 5 minutes) or reduce the sample volume (e.g., to 10 µL). The changed reaction time (T) and/or sample volume (V₁) must be substituted into the calculation formula.3. Calculation of Results3.1 Based on Sample MassUnit Definition: One unit of enzyme activity is defined as the amount that consumes 1 nmol of NADH per minute per gram of tissue.Derived Formula: chl PGK (nmol/min/g fresh weight) = [ΔA ÷ (ε × d) × V₂ × 10⁹] ÷ (W × V₁ ÷ V) ÷ TSimplified Formula: chl PGK (nmol/min/g fresh weight) = 321.6 × ΔA ÷ W3.2 Based on Sample Protein ConcentrationUnit Definition: One unit of enzyme activity is defined as the amount that oxidizes 1 nmol of NADH per minute per mg of tissue protein.Derived Formula: chl PGK (nmol/min/mg prot) = [ΔA ÷ (ε × d) × V₂ × 10⁹] ÷ (V₁ × Cpr) ÷ TSimplified Formula: chl PGK (nmol/min/mg prot) = 321.6 × ΔA ÷ CprParameter Definitions:ε: Molar extinction coefficient of NADH (6.22 × 10³ L/mol/cm)d: Light path length for the 96-well plate (0.5 cm)V: Volume of Extraction Buffer added to the pellet (1 mL)V₁: Volume of sample added to the reaction (0.02 mL)V₂: Total volume of the reaction system (0.2 mL = 2.0 × 10⁻⁴ L)T: Reaction time (10 minutes)W: Sample weight (g)Cpr: Sample protein concentration (mg/mL); Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) is recommended.Precautions It is strongly recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure. Based on the preliminary results, determine or adjust sample concentrations to prevent unnecessary waste of samples or reagents... Read More | O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water 10 mL RT O665690G Spin Columns FS with Collection Tubes 50 EA RT O665690H Spin Columns RM with Collection Tubes 50 EA RT O665690I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProduct IntroductionThis kit is suitable for extracting RNA from a wide range of plants, even from plants rich in polysaccharides and polyphenols, high quality RNA can be successfully extracted, such as rice leaves, wheat leaves, corn leaves, tobacco leaves, pine needles, ginkgo leaves, poplar leaves, pomegranate leaves, holly leaves, apples, peaches, pears, tomatoes, cherries, apricots, bananas, grapes, loquats, cinnamon rinds, cinnamon pulp, lychee fruit rinds, lychee pulp, soybean, peanut, corn, potato tuber, moonflower petal, pomegranate petal, shiitake mushroom, flat mushroom and other samples. The unique lysate formula can rapidly inactivate the RNA enzyme in the cell, effectively remove the effect of polysaccharide and polyphenol on RNA extraction, without the need for phenol, chloroform and other reagents, while using silicon matrix membrane adsorption of RNA for purification, the total RNA extracted is highly pure, without the contamination of genomes, proteins and other impurities, and can be used for Real Time RT-PCR, RT-PCR, It can be used for Real Time RT-PCR, RT-PCR, Northern Blot, Dot Blot, in vitro translation and other downstream experiments.RNA yieldSelf-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction)Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips.(2) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the rate and quality of RNA extraction.3. If Buffer RLS produces a precipitate, heat to dissolve it and leave at room temperature.4. Please add β-mercaptoethanol to Buffer RLS before use, add 20µl β-mercaptoethanol to 1ml Buffer RLS. Buffer RLS with β-mercaptoethanol can be stored for 1 month at room temperature.5. Anhydrous ethanol should be added according to the instructions on the reagent bottle label before using Buffer RW2 for the first time. Operation steps1. Homogenization: Take 50-100mg of plant tissue and quickly grind it into powder in liquid nitrogen, add 500µl of Buffer RLS (please check whether β-mercaptoethanol is added before use), and immediately mix it by vortexing with vigorous shaking.Note: For materials that are extremely rich in water content, such as watermelon pulp, tomato, pear pulp, etc., more material can be added appropriately, up to 200 mg; for starch-rich samples or mature leaves, the amount of Buffer RLS can be increased appropriately, up to 700 µl.2. Centrifuge at 12,000 rpm (~13,400 x g) for 2 min at 4°C.3. Transfer the supernatant into the filter columns (Spin Columns FS) that have been loaded into the collection tubes, centrifuge at 12,000 rpm at 4°C for 1 minute, carefully aspirate the supernatant in the collection tubes and transfer it to new RNase-Free centrifugation tubes (self-provided), avoiding the tip of the gun from touching the cell debris precipitation in the collection tubes as much as possible.4. Slowly add 0.5 times the volume of the supernatant in anhydrous ethanol, mix well (a precipitate may appear), and transfer the resulting solution together with the precipitate to a Spin Columns RM in a collection tube, or in two batches if you cannot add all of the solution at once. centrifuge the column for 1 minute at 12,000 rpm at 4°C. Dispose of the spent solution and place the column back into the collection tube. Centrifuge at 12,000 rpm for 1 minute at 4°C, discard the spent solution and return the column to the collection tube.5. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and prepare a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.9. Add 500 µl of Buffer RW2 to the adsorbent column RM (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute at 4°C, discard the waste solution and put the adsorbent column back into the collection tube.10. Repeat step 9.11. Centrifuge at 12,000 rpm for 2 minutes at 4°C.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column RM into new RNase-Free Centrifuge Tubes (1.5 ml), add 30-50 µl of RNase-Free Water dropwise to the middle part of the adsorption membrane overhang, leave it at room temperature for 2 min, and centrifuge at 12,000 rpm at 4°C for 1 min, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL R669988 Component 50T Storage R669988A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. R669988B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. R669988C Buffer RL 35 mL RT R669988D Buffer RLC 35 mL RT R669988E Buffer RW1 40 mL RT R669988F Buffer RW2 (concentrate) 11 mL RT R669988G RNase-Free Water 10 mL RT R669988H Spin Columns FL with Collection Tubes 50 sets RT R669988I Spin Columns RM with Collection Tubes 50 sets RT R669988J RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProductsThis kit is used for the extraction and purification of high-quality total RNA from a variety of plants, and is also suitable for the extraction of fungal mycelial RNA. The unique separation column is used for homogenization and filtration of high viscosity plant or fungal lysates, while the silicon matrix membrane is used to adsorb the RNA for purification, so that various contaminants, such as polysaccharides, are effectively removed by washing, and the eluted RNA can be directly used in various downstream experiments. The molecular weight of RNA extracted by this kit is more than 200 bases, with high purity and almost no DNA residue. For RNA experiments that are very sensitive to trace DNA, the residual DNA can be removed by digestion on a column using RNase-free DNase. The extracted RNA can be used in Northern Blot, Dot Blot, RT-PCR and in vitro translation experiments.Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry-roasted at 180°C for 4 hours before use, and plasticware can be soaked in 0.5M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.3. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.4. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL, it can be stored for 1 month at room temperature. Buffer RL with β-mercaptoethanol can be stored at room temperature for 1 month. β-mercaptoethanol is not required for use of Buffer RLC.5. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.6. If precipitation occurs in Buffer RL and Buffer RLC, heat to dissolve and leave at room temperature.7. All centrifugation steps are carried out at room temperature and all steps are performed quickly. Procedure1. 50-100 mg of plant tissue is quickly ground to a powder in liquid nitrogen and added to 600 µl of Buffer RL (check for addition of β-mercaptoethanol before use) or Buffer RLC. vortexing and oscillating to allow for adequate lysis.Note: 1) The main component of Buffer RL is guanidine isothiocyanate, which is suitable for lysis of most plant tissues. However, in some plant tissues (e.g. endosperm of corn), due to the special secondary metabolites, guanidine isothiocyanate causes precipitation of the sample, resulting in poor RNA extraction, in this case, Buffer RLC can be added instead of Buffer RL.2) Incubation at 56°C for 1-3 minutes helps tissue lysis, but do not incubate at high temperatures for plants with high starch content.2. Transfer all the liquid obtained in step 1 to an adsorption column (Spin Columns FL) that has been loaded into a collection tube, centrifuge at 12,000 rpm (~13,400 x g) for 2 minutes, and transfer the supernatant from the collection tube to a new centrifuge tube (supplied).Note: 1) The tip of the tip of the gun can be cut off when aspirating liquids to facilitate sampling.2) Spin Columns FL removes most of the debris, but a small portion will still flow out and a precipitate will form in the collection tube after centrifugation, so be careful to avoid aspirating the precipitate when proceeding to the next step.3. Add 0.5 times the volume of anhydrous ethanol to the clean lysate obtained in step 2 and mix rapidly.Note: Precipitation may occur upon addition of ethanol, but does not affect subsequent tests.4. Transfer the solution obtained in the previous step to the Spin Columns RM in the collection tube. If it is not possible to add all of the solution to the column at one time, centrifuge the column at 12,000 rpm for 15 seconds in two batches, discard the waste solution and put the column back into the collection tube.5. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and make a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorption column, centrifuge at 12,000 rpm for 1 minute, discard the waste liquid and put the column back into the collection tube.9. Add 500 µl of Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 15 seconds, and discard the waste solution.10. Repeat step 9.11. Place the adsorbent column back into the collection tube, centrifuge at 12,000 rpm for 1 minute, and allow the column to come to room temperature for a few minutes to thoroughly dry out the anhydrous ethanol in the adsorbent column.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 minute, centrifuge at 12,000 rpm for 1 minute, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More |