| Description | Chloroplast 3-phosphoglycerate kinase (PGK) is a key enzyme in the Calvin cycle. Detection Principle: Chloroplast 3-phosphoglycerate kinase catalyzes the reaction of 3-phosphoglyceric acid and ATP to produce 1,3-bisphosphoglyceric acid. The latter, under the action of glyceraldehyde-3-phosphate Chloroplast 3-phosphoglycerate kinase (PGK) is a key enzyme in the Calvin cycle. Detection Principle: Chloroplast 3-phosphoglycerate kinase catalyzes the reaction of 3-phosphoglyceric acid and ATP to produce 1,3-bisphosphoglyceric acid. The latter, under the action of glyceraldehyde-3-phosphate dehydrogenase and NADH, produces glyceraldehyde-3-phosphate and NAD⁺. The enzyme activity of 3-phosphoglycerate kinase is determined by measuring the decrease in NADH.Component96TStorageExtraction Buffer 1100 mL2-8℃Extraction Buffer 2100 mL2-8℃Reagent 11EA-20℃. Store in the dark.Reagent 23EA2-8℃Reagent 31EA-20℃Reagent 435 mL2-8℃Reagent 51EA-20℃Reagent Preparation:Reagent 1 (Powder, 1 vial):Before opening, ensure the powder is at the bottom (can be flicked manually).Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.Reagent 2 (Powder, 3 vials):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 0.4 mL of distilled water per vial to dissolve. Use after preparation.Unused dissolved reagent can be aliquoted and stored at -20°C. Avoid repeated freeze-thaw cycles. Use within 3 days.Reagent 3 (Powder, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.Reagent 5 (Powder, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 minutes to collect the powder at the bottom.Add 1.1 mL of distilled water to dissolve. Use after preparation.The prepared solution can be stored for the duration of the kit's validity period.User-Prepared Instruments and MaterialsMortar (Homogenizer), Ice box (Ice maker), Benchtop centrifuge, Adjustable micropipettes, Water bath (Oven, Incubator, Metal bath), 96-well plate, Centrifuge tubes, Microplate reader, Vortex mixer/shaker, Distilled water (Deionized water or Ultrapure water are acceptable).Experimental ProcedureIt is recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure and to determine or adjust sample concentrations based on the preliminary results, preventing unnecessary waste of samples or reagents.1. Sample Extraction (Chloroplast Isolation)Weigh approximately 0.1 g of plant tissue sample. Add 1 mL of Extraction Buffer 1 and homogenize rapidly in an ice bath. Centrifuge at 1,600 rpm, 4°C for 5 minutes. Discard the pellet. Take the supernatant and centrifuge again at 5,000 rpm, 4°C for 15 minutes. Discard the supernatant and keep the pellet. Add 1 mL of Extraction Buffer 2 to the pellet. Vortex vigorously for 15 seconds. Place on ice (or in a refrigerator) and incubate at 4°C for 15 minutes. Centrifuge at 13,000 rpm, 4°C for 5 minutes. Collect the supernatant for assaying the chloroplast 3-phosphoglycerate kinase (PGK) enzyme activity.Important: The entire chloroplast extraction process must be maintained at 4°C.Note: If increasing the sample amount, maintain a tissue mass (g) to Extraction Buffer volume (mL) ratio between 1:5 and 1:10.2. Assay Steps2.1 Preheat the microplate reader for 30 minutes. Set the wavelength to 340 nm and the temperature to 25°C.2.2 Thaw all reagents to room temperature (25°C).2.3 Add reagents sequentially to a 96-well plate:ReagentTest Well (µL)Sample20Reagent 110Reagent 210Reagent 310Reagent 4140Mix well and incubate at room temperature (25°C) for 10 minutes.Reagent 510Mix gently. Under room temperature (25°C) conditions, read the absorbance at 340 nm at 30 seconds (A₁) and then again after 10 minutes (A₂). Calculate ΔA = A₁ - A₂.注:Notes:(1) If ΔA is close to zero, the reaction time can be appropriately extended to 20 minutes before reading A₂. If the reaction time is changed, the new time (T) must be substituted into the calculation formula. Alternatively, the sample volume can be increased (e.g., to 40 µL, with a corresponding decrease in Reagent 4 volume); the new sample volume (V₁) must then be substituted into the calculation formula.(2) If the decrease trend is unstable, read the absorbance every 20 seconds and select a linearly decreasing time period for calculation. The corresponding A values for this period should be used to calculate ΔA and substituted into the formula.(3) If the initial absorbance A₁ is too high (e.g., >2, as in dark green plant leaves with high pigment content), consider appropriately reducing the sample volume; the new sample volume (V₁) must be substituted into the calculation formula. Alternatively, add a small amount of activated carbon to the sample, mix, let stand for 5 minutes, then centrifuge at 12,000 rpm, 4°C for 10 minutes, and use the supernatant for assay.(4) If ΔA is greater than 0.5, reduce the reaction time (e.g., to 5 minutes) or reduce the sample volume (e.g., to 10 µL). The changed reaction time (T) and/or sample volume (V₁) must be substituted into the calculation formula.3. Calculation of Results3.1 Based on Sample MassUnit Definition: One unit of enzyme activity is defined as the amount that consumes 1 nmol of NADH per minute per gram of tissue.Derived Formula: chl PGK (nmol/min/g fresh weight) = [ΔA ÷ (ε × d) × V₂ × 10⁹] ÷ (W × V₁ ÷ V) ÷ TSimplified Formula: chl PGK (nmol/min/g fresh weight) = 321.6 × ΔA ÷ W3.2 Based on Sample Protein ConcentrationUnit Definition: One unit of enzyme activity is defined as the amount that oxidizes 1 nmol of NADH per minute per mg of tissue protein.Derived Formula: chl PGK (nmol/min/mg prot) = [ΔA ÷ (ε × d) × V₂ × 10⁹] ÷ (V₁ × Cpr) ÷ TSimplified Formula: chl PGK (nmol/min/mg prot) = 321.6 × ΔA ÷ CprParameter Definitions:ε: Molar extinction coefficient of NADH (6.22 × 10³ L/mol/cm)d: Light path length for the 96-well plate (0.5 cm)V: Volume of Extraction Buffer added to the pellet (1 mL)V₁: Volume of sample added to the reaction (0.02 mL)V₂: Total volume of the reaction system (0.2 mL = 2.0 × 10⁻⁴ L)T: Reaction time (10 minutes)W: Sample weight (g)Cpr: Sample protein concentration (mg/mL); Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) is recommended.Precautions It is strongly recommended to first perform a preliminary test using 1-3 samples with expected significant differences (e.g., different types or groups) to familiarize yourself with the procedure. Based on the preliminary results, determine or adjust sample concentrations to prevent unnecessary waste of samples or reagents... Read More | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | DescriptionProvides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits and KitAlysis 24-Well Reaction Block | Product contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. AvoidProduct contentU665751Component100 TStorageU665751A2×UltraSYBR One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751BUltraSYBR One Step EnzymeMix50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.U665751DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR. The SYBR Green I fluorescent dye contained can bind to all double-stranded DNA, allowing this product to be used for the detection of many different target sequences without the need to synthesize specific labeling probes. Real Time RT-qPCR reaction using this product, reverse transcription and quantitative PCR are carried out in the same reaction system, there is no need to add reagents during the reaction, no need to open the cap of the tube, avoiding contamination while improving the efficiency of the experiment. The new high-efficiency reverse transcriptase RNase H is activity-deficient, which reduces the degradation of RNA in the reverse transcription reaction. The enzyme has high reverse transcription efficiency and can perform a good reverse transcription reaction on a small amount of RNA template. It has high affinity to RNA and can read through RNA templates with high GC content and complex secondary structure. New efficient hot start enzyme, the enzyme activity is closed at room temperature, thus effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, which greatly improves the accuracy of fluorescence quantitative PCR reaction. The included buffer system maximizes the efficacy of both enzymes at the same time and improves efficiency. This product has high sensitivity, high specificity, wide linear range, and more accurate quantification of target genes.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used with Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (U665567) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (U665751) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2. This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether of pyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes before use. Sterilize for 30 minutes before use.3. UltraSYBR One Step RT-qPCR Buffer contains SYBR Green I fluorescent dye. Avoid bright light when storing this product or preparing PCR reaction solutions.4. Repeated freezing and thawing of each reagent in this kit should be avoided; repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.5. This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-PCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.6. This product cannot be used for fluorescent quantitative PCR by the probe method.Usage1. Dissolve RNA template, primers, 2× UltraSYBR One Step Buffer, UltraSYBR One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:Reagents25 µl Reaction systemFinal concentration2×UltraSYBR One Step Buffer12.5 µl1×Forward Primer,10 µM0.5 µl0.2 µM¹⁾Reverse Primer,10 µM0.5 µl0.2 µM¹⁾UltraSYBR One Step EnzymeMix0.5 µl RNA TemplateX µl10 pg – 100 ng50×Low ROX or High ROX(optional)2)0.5 µl1×RNase-Free Waterup to 25 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and the final concentration of 0.1-0.5µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; when non-specific reaction occurs, the concentration of primer can be decreased, thus optimizing the reaction system.(2) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Vortex and shake to mix, centrifuge briefly, and collect the solution at the bottom of the tube.4. RT-qPCR reaction conditions (fluorescence quantitative PCR is a two-step method), this program is based on the ABI 7500 fluorescence quantitative PCR instrument as an exampleNote: 1) It is recommended to use two-step PCR reaction program, if you improve the reaction specificity, you can increase the annealing temperature to 60-64 ℃ as a reference for the setting range; if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument used, and this program is set up with the ABI 7500 fluorescence quantitative PCR instrument as a reference.RT-qPCR reaction conditions (fluorescence quantitative PCR was a three-step method):Note: 1) For three-step PCR amplification, please use the range of 56℃-64℃ as the setting reference for the annealing temperature.(2) For melting curve analysis, please set up the program recommended by the fluorescence quantitative PCR instrument you are using, this program is ABI750 fluorescent quantitative PCR instrument as a reference setting... Read More |