| Description | Inquire | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | Inquire | Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 mLRTR669990GSpin Columns RM with Collection Tubes50 setsRTR669990HRNase-Free Centrifuge Tubes (1.5 mL)50 EART ProductsThis kit combines highly efficient guanidine isothiocyanate cleavage technology with silica matrix membrane purification for the efficient extraction of total RNA from animal cells and tissues, typically up to 30 mg of tissue or 1x107 cells as a starting sample. The kit also allows recovery of incompletely purified RNA, in vitro transcription and RNA from enzymatic reactions. high quality RNA with molecular weights greater than 200 bases can be extracted and purified using the kit with virtually no DNA residue. If RNA experiments that are very sensitive to trace DNA are to be performed, residual DNA can be removed by on-column digestion using RNase-free DNase. The extracted RNA can be used in downstream experiments such as RT-PCR, Nothern Blot and Dot Blot. Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.3. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL. Buffer RL with β-mercaptoethanol can be stored for 1 month at room temperature.4. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.5. Buffer RL may be heated at 56°C to dissolve if precipitation occurs and then left at room temperature.All centrifugation steps are performed at room temperature and all maneuvers are performed quickly.Procedure1. Sample handling1a Tissue: Grind tissue in liquid nitrogen. Add 600 µl Buffer RL for every 20-30 mg of tissue (check for addition of β-mercaptoethanol before use), and 350 µl Buffer RL for tissue samples of less than 20 mg. Sample volume is not to exceed one-tenth of the Buffer RL volume.1b Cells in monolayer culture: Lysed or processed into cell suspension directly in culture flask, centrifuged to obtain cell precipitate, discarded the supernatant, added 600µl Buffer RL for every 6-10 cm2 of culture area, 350µl Buffer RL for less than 6cm2, and blown several times repeatedly to make the cells lysed sufficiently.1c Cell suspension: centrifuge at 12,000 rpm (~13,400 × g) for 1 min and discard the supernatant to obtain the cell precipitate. Add 600 µl Buffer RL for every 5×106-1×107 cells, and 350 µl Buffer RL for less than 5×106 cells, and blow several times repeatedly to fully lysate.Note: 1) Try to get rid of the cell culture medium, which may inhibit cell lysis affecting RNA yield.2) Try to keep the cells well suspended and well lysed, otherwise RNA yield is affected.2. After the sample is fully lysed, leave it at room temperature for 5 minutes to allow complete separation of the protein-nucleic acid complex.3. Centrifuge at 12,000 rpm for 2-5 min and remove the supernatant for the following operations.4. Add 1x volume (600µl or 350µl) of 70% ethanol (prepared without RNase water) to the solution obtained in step 3 and mix well.Note: The addition of ethanol may produce a precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in the previous step to the Spin Columns RM in the collection tube. If you cannot add all of the solution to the column at once, transfer it in two passes, centrifuge at 12,000 rpm for 1 minute, and discard the waste solution. Place the column back into the collection tube.Note: The maximum loading capacity of the adsorption column is 100µg, do not overload as this will affect the yield and purity of the RNA.6. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.7. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water, add 8 µl of 10×Reaction Buffer and 20 µl of DNase I (1 U/µl) to it, mix well, and prepare a final volume of 80 µl of reaction solution.8. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.9. Add 200 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.10. Add 500µl Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.11. Repeat step 10.12. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the adsorption column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).13. Transfer the adsorbent column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 min, centrifuge at 12,000 rpm for 1 min, collect the RNA solution, and store the RNA at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Wate should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 13 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 13 repeated... Read More | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. The reverse transcriptase used in this kit is a novel and efficient reverse transcriptase that utilizes E. coli engineered bacteria for recombination and expression. It removes This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. The reverse transcriptase used in this kit is a novel and efficient reverse transcriptase that utilizes E. coli engineered bacteria for recombination and expression. It removes RNase H activity and enhances its thermal stability. It can synthesize cDNA first strands using extremely low amounts of total RNA or mRNA, with an initial sample size as low as pg level. SuperRT reverse transcriptase has strong affinity for RNA and can read RNA templates with high GC content and complex secondary structures, obtaining high yields of cDNA. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including Super RT efficient reverse transcriptase, reaction buffer, primers, dNTP, etc. It is simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. S665657 Component 100 T Storage S665657A SuperRT, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. S665657B 5×SuperRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. S665657C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. S665657D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. S665657E RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle.Product features:·Efficient reverse transcription: It has a high affinity for RNA templates, with a reverse transcription efficiency of up to 90%, and can recognize pg level templates.·Free response to complex templates: Even templates with high GC content and complex secondary structures can achieve good results without high-temperature denaturation.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Note: 1 ng -5 µ g of total RNA can establish a 20 µ l reaction system. If the total RNA amount is greater than 5 µ g, please expand the reaction system proportionally.Steps for reverse transcription:1. Dissolve the RNA template, Primer Mix, dNTP Mix, SuperRT Buffer, SuperRT, and RNase Free Water and place them on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 50 pg-5 µg SuperRT,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer. Oligo dT Primer or Gene Specific Primer can be used according to experimental needs, with a recommendation of 20 µ The reaction system Oligo dT Primer is 50 pmol, or Gene Specific Primer is 2 pmol.3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe.Incubate at 4.42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time. Reagent 20 µ Final concentration of reaction system dNTP Mix, 2.5 mM Each 4 µ L 500 µ M Each Primer Mix 2 µ RNA Template X µ L 50 pg-5 µ g 5 x SuperRT Buffer 4 µ 1 x SuperRT, 200 U/ µ L 1 µ RNase Free Water up to 20 µ Lii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve the RNA template, Primer Mix, dNTP Mix, SuperRT Buffer, SuperRT, and RNase Free Water and place them on ice for later use.2. Configure the reaction system according to the following table, with a total volume of 15 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 50 pg-5 µg RNase-Free Water up to 15 µl / Note: Primer Mix is formulated from Oligo (dT) and Random Primer. Oligo dT Primer or Gene Specific Primer can be used according to experimental needs. 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×SuperRT Buffer 4 µl 1× SuperRT,200 U/µl 1 µl / Note: If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNasins). This kit is not provided. 6. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More |