| Description | Hotstart HiTaq& Script III combines high-speed thermal cycling with exceptional quantification accuracy. Featuring a thermostable reverse transcriptase (HS Script III RTase) and chemical-modified hot-start Taq DNA polymerase (Hotstart HiTaq), it enables contamination-resistant, single-tube Real-Hotstart HiTaq& Script III combines high-speed thermal cycling with exceptional quantification accuracy. Featuring a thermostable reverse transcriptase (HS Script III RTase) and chemical-modified hot-start Taq DNA polymerase (Hotstart HiTaq), it enables contamination-resistant, single-tube Real-Time One-Step RT-PCR with superior sensitivity—ideal for detecting low-abundance RNA targets (e.g., RNA viruses). This master mix is specifically designed for convenient, high-sensitivity one-step RT-PCR. Its unique enzyme system and specially formulated buffer ensure efficient and accurate reverse transcription and PCR amplification without requiring optimization. It delivers excellent standard curves across a broad quantitative range, enabling precise target gene quantification with high reproducibility and reliability. Suitable for hot-start RNA amplification.Product Component ListU1492576Component100T200TStorageU1492576A4×RT PCR Buffer625 µL2.5 mL-20℃U1492576BHotstart HiTaq& Script III100 µL400 µL-20℃.Protocol1. Pre-Reaction SetupThaw components on ice. Avoid freeze-thaw cycles.Prepare reactions on ice.2. Reaction AssemblyComponentVolume/25 µLVolume/50 µLFinal Concentration4×RT PCR Buffer6.25 µL12.5 µL1×Hotstart HiTaq& Script III1 µL2 µL2/50 µLPrimer-Probe Mix1 µL2 µL/Template (RNA)5 µL10 µL/ddH2OTo 25 µLTo 50 µL/Total Volume25 µL50 µL* Enzyme activity: 2 U Hotstart HiTaq + 5 U HS Script III per 50 µL reactionNotes:Adjust primer/probe/template volumes as needed.Protect probes from light.3. Mixing & CentrifugationGently pipette-mix → Centrifuge briefly.4. Cycling ConditionsStepTemperatureTimeCyclesReverse Transcription50℃15min1Initial Denaturation95℃10min1Denaturation95℃10s45Annealing/Extension55℃40s45Hold12℃∞1... Read More | Inquire | Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and Glycogen and starch generate glucose-1-phosphate (1PG/G1P) during the process of phosphohydrolysis. This reagent kit provides a simple, sensitive, and rapid determination method: Glucose-1-phosphate (1PG/G1P) is reduced from NADP+to NADPH by the sequential action of phosphoglucose mutase and phosphoglucose dehydrogenase. The content of glucose-1-phosphate (1PG/G1P) in the sample can be calculated by detecting the increase in NADPH at 340nm.Composition and preparation of reagent kit: Reagent name Specifications Save requirements Remarks Extraction solution Liquid 100mL x 1 bottle 4 ℃ storage / Reagent 1 Powder mg x 1 tube 4 ℃ storage Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 2 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then dissolve it in 1.2mL of distilled water for later use. Reagent 3 Liquid 16mL x 1 bottle 4 ℃ storage / Reagent 4 Powder mg x 1 tube Store at -20 ℃ Shake or centrifuge the reagent a few times before use to make it fall to the bottom, then add 1 Dissolve 1mL of distilled water for later use. TRC 1 powder 4 ℃ storage Only used to identify whether the reagents in the kit are normal (not involved in result calculation). Usage: Use a pre standard tube (GIP) to shake the powder a few times until it falls to the bottom, then add 0.5mL of distilled water and mix well to dissolveDilute GIP with a concentration of 4mg/mL and then dilute it four times to 1mg/mL for later use: follow the instructions in the sample addition table for the measuring tube operationRequired instruments and supplies:ELISA reader, 96 well plate, desktop centrifuge, adjustable pipette, mortar, ice and distilled water.Determination of glucose-1-phosphate (1PG/G1P) content:1. Sample preparation① Organizational sample:Suggest weighing around 0 1g of tissue, add 1mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12000rpm, 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, it can be extracted in a ratio of tissue mass (g) to extraction solution volume (mL) of 1:5-10.② Bacterial/cellular samples:Collect bacteria or cells into a centrifuge tube first, centrifuge and discard the supernatant; Take about 5 million bacteria or cells and add them to 1mLExtract solution, sonicate bacteria or cells (ice bath, power 200W, sonication for 3s, interval 10s, repeated 30 times); Centrifuge at 12000rpm at 4 ℃ for 10 minutes, take the supernatant, and place it on ice for testing.[Note]: If the sample size is increased, extraction can be carried out in a ratio of 500-1000:1 of bacteria/cell quantity (104) to extraction solution (mL).③ Liquid sample: direct detection.2. Machine testing:① Preheat the enzyme-linked immunosorbent assay (ELISA) reader for at least 30 minutes and adjust the wavelength to 340nm.② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table:② Thaw the reagent to room temperature (25 ℃);③ Add reagents to the 96 well plate in the following order according to the table: Reagent name (µL) Measurement tube Blank tube (only done once) Reagent 1 10 10 Reagent 2 10 10 Reagent 3 150 170 Sample 20 / Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A1 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Reagent 4 10 10 Mix well, incubate at room temperature (25 ℃) for 20 minutes, and then read A2 at 340nm (if the A value continues to increase, the incubation time needs to be extended until the absorbance value remains unchanged within 2 minutes). Δ A=(A2-A1) measurement - (A2-A1) blank.[Note] 1 If the difference in Δ A is hovering around zero, the sample size V1 can be increased (such as increasing to 50 µ L, the three phases of the reagent should be reduced while keeping the total volume unchanged), or the sample sampling mass W can be increased. The changed V1 and W need to be substituted into the formula for recalculation.If the A2 value exceeds 1.2, the amount of sample added V1 can be reduced (such as to 10 µ L, the three-phase reagent should be increased while keeping the total volume unchanged), or the sample can be diluted with distilled water (keeping the sample addition system unchanged), and the changed V1 and D need to be substituted into the formula for recalculation.Result calculation:1. Calculated by sample weight:1PG/G1P content (µ g/g fresh weight)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (W × V1 ÷ V) × D=836 × Δ A ÷ W × D2. Calculated by the number of cells:1PG/G1P content (µ g/104 cell)=[(Δ A ÷ (ε× d) × V2 × 106 × MR] ÷ (500 × V1 ÷ V) × D=1.7 × Δ A × D. 3. Calculated by liquid volume:1PG/G1P content (µ g/mL)=[(Δ A ÷ (ε× d) × V2 × 106 × Mr] ÷ V1=836 × Δ A ε---NADPH Molar extinction coefficient,6.22×103 L/mol/cm; d---96 Orifice plate optical diameter,0.5cm; V---Add volume of extraction solution,1 mL; V1---Add sample volume,0.02mL V2---Total reaction volume;0.2mL=2×10-4L; W---Sample quality,g; Mr---Glucose-1-phosphate(1PG/G1P)Molecular weight;260; 500---Number of cells, in millions; D---Dilution ratio,Undiluted is 1。 /... Read More | Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of Product content: Component G665666 200 preps Buffer P1 60ml Buffer P2 60ml Buffer E3 60ml Buffer PW (concentrate) 25ml Buffer EB 30ml RNase A (10 mg/ml) 600 µl Spin Columns DM 200 with Collection Tubes 200Product Introduction:This reagent kit is suitable for extracting 1-5 ml of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed with a special buffer system to effectively remove impurities such as proteins. The yield and purity of plasmids obtained from this kit are high, and the quality is stable. It is suitable for downstream experiments such as cell transfection, DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. 2.Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. Before use, add RNase A to Buffer P1 (add all RNase A provided in the reagent kit), mix well, and store at 2-8 ℃. Before use, it is necessary to leave it at room temperature for a period of time, and then use it after returning to room temperature.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Note that Buffer P2 and Buffer E3 contain irritating substances. Please wear gloves when operating and immediately cover the lid after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.7. The maximum volume of Spin Columns DM is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.Operation steps:1. Take 1-5 ml of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 1 minute to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 200 to the centrifuge tube containing bacterial sediment µ Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 200 to the centrifuge tube µ Buffer P2, gently invert and mix 8-10 times to fully lyse the bacterial cells. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too large and the lysis may not be complete. The bacterial count should be reduced or the dosage of P1, P2, E3, and isopropanol should be increased proportionally.4. Add 200 to the centrifuge tube µ Buffer E3, immediately invert and mix 8-10 times, at which point white flocculent precipitates appear. Centrifuge at 13000 rpm for 5 minutes.Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation.5. Add 260 to the spin columns DM that have been loaded into the collection tube µ After adding isopropanol, immediately add the supernatant collected in step 4 and mix it upside down.Attention: After adding isopropanol, immediately add the supernatant and mix well to avoid isopropanol dripping into the collection tube after being left for a long time. The maximum volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ l. Isopropanol and the supernatant can be collected in a centrifuge tube (provided by oneself), mixed well, and passed through the column in batches.6.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 400 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.8. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ Centrifuge at 13000 rpm for 1 minute using buffer EB and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Product content: O665490Component50 TStorageO665490ABlocking Buffer500 mL2-8℃. Do not freeze.O665490BAntibody Pretreat Solution (HRP/Rabbit)5×1 mL2-8℃. Do not freeze.O665490CDilution Buffer500 mL2-8℃. Do not freeze.O665490DWash Buffer (10×)500 mL2-8℃. Do not Product content: O665490Component50 TStorageO665490ABlocking Buffer500 mL2-8℃. Do not freeze.O665490BAntibody Pretreat Solution (HRP/Rabbit)5×1 mL2-8℃. Do not freeze.O665490CDilution Buffer500 mL2-8℃. Do not freeze.O665490DWash Buffer (10×)500 mL2-8℃. Do not freeze. Product Introduction:The one-step rapid WB assay kit (rabbit) is the latest Western Blot detection kit developed by Kangwei Century, which canObtain high-quality Western Blot results within about 1 hour, with simple operation, high detection sensitivity, low background, and noAdditional secondary antibodies need to be added, with strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding)Combining with secondary antibodies requires a long time, a complex experimental process, and requires multi-step optimization of conditions. The protein on the glue is transferred toAfter coating the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier with the primary antibody treated with antibody reaction solutionAfter washing the membrane three times (5 minutes each time), it can undergo luminescence or color detection. This reagent kit is designed for target protein oneThe use of an experimental system derived from rabbits.Notes:1. Customers need to prepare their own rabbit source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Rabbit) antibody reaction solution (rabbit), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (rabbit) needs to be determined through preliminary experiments.6. Antibody reaction solution HRP (rabbit), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. Antibodies with low specificity and affinity are not recommended for repeated use. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Rabbit) 100 µ Add rabbit derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (rabbit) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Rabbit), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the membrane surface). Incubate at room temperature on a shaker at a speed of about 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes.7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Example 1: Antigen 293T cell lysateA: Ordinary WB control: beta actin rabbit antibody (CW0097) 3.3ug incubated at room temperature for 40 minutes, washed with membrane, secondary antibody sheep anti rabbit HRP (CW0103) diluted at 1:10000, room temperature for 40 minutes, ECL (CW0049) exposed Example 2 Antigen is 293T cell lysateC: Ordinary WB control: PAK1, Epitomics rabbit monoclonal antibody 1:1000, incubated at room temperature for 40 minutes, washed with membrane, secondary antibody sheep anti rabbit HRP (CW0103) diluted at 1:10000, room temperature for 40 minutes, ECL (CW0049) exposedD: One step WB: Epitomics rabbit monoclonal antibody was incubated at 1:1000 room temperature for 40 minutes, and ECL (CW0049) was exposed... Read More |