| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For DescriptionThe Baran Late-Stage Toolkit is a convenient collection of 12 highly innovative reagents that are highly effective in the diversification of complex molecules. The contents in the box are 11 Baran Diversinates™and one vial of Palau′Chlor®in amounts of 100 mg each. For obtaining larger amounts of any desired kit component, see the kit component table at the bottom of the page.Useful Topics:Late Stage FunctionalizationBaran Group – Professor Product PortalPalau′ChlorDiversinates... Read More | Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar Products content Products IntroductionThis kit is a dedicated sample preparation solution for microbiome analysis and is suitable for the purification and enrichment of genomic DNA of pathogenic microorganisms such as bacteria and fungi from mixed samples such as swabs, blood, sputum, alveolar lavage, etc. During the purification process, differential lysis of the host cells and subsequent enzymatic digestion can effectively remove most of the host DNA while providing a comprehensive coverage of the bacterial and fungal DNA loci to a higher level. By differential lysis of host cells and subsequent enzymatic digestion, this kit can effectively remove most of the host DNA while maximizing the full coverage of bacterial, fungal and other pathogenic microbial DNA sites, thus obtaining microbiome DNA enrichment products with a higher coverage. Microbial DNA purified with this kit is suitable for a variety of downstream applications, including whole genome sequencing analysis, 16S rDNA-based high sensitivity microbiome analysis, and macrogenomic birdshot sequencing analysis. Self-contained reagents and consumablesSterile pipette tips with aerosol barrier to prevent cross-contamination anhydrous ethanol Microcentrifuge tubes (2 ml/1.5 ml) PBS buffer (required for some samples only)Pre-experiment Preparation and Important Notes1. Add 1.25 ml Proteinase K Storage Buffer to Proteinase K and store at -20℃. Do not leave the prepared Proteinase K (20 mg/ml) at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Dissolve Lysozyme (100 mg) in 10 ml Enzymatic Lysis Buffer to a final concentration of 10 mg/ml, dispense into sterile tubes and store at -20℃. Do not leave the prepared Lysozyme (10 mg/ml) at room temperature for a long time and avoid repeated freezing and thawing to avoid affecting its activity.3. Thaw Buffer GB1 and Buffer GB2 at room temperature or 2-8°C before use and mix thoroughly. Thawed Buffer GB1 and Buffer GB2 can be left at 2-8°C for 1-2 weeks without affecting their activity, and should be stored at -20°C for long term storage. To ensure optimal performance, do not freeze or thaw more than three times. If less than one bottle of Buffer GB1 and Buffer GB2 is required for a single extraction, ensure that it is used under sterile conditions such as an ultra-clean bench and avoid microbial contamination and growth in the remaining buffer.4. Before first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the vial label and labeled.5. Check Buffer GL for crystallization or precipitation before use, and if crystallization or precipitation occurs, redissolve Buffer GL in a 56°C water bath.6. If the downstream experiments are sensitive to RNA contamination, 4 µl of DNase-Free RNase A (100 mg/ml) can be added before adding Buffer GL. RNase A is not provided in the kit, but can be ordered separately from CW0601S.7. This kit is designed for the isolation of DNA from intact microbial cells. To ensure optimal recovery of microbial DNA, samples should be fresh. If storage or transportation is required, this should preferably be done at 2-8°C and not frozen or thawed, as freezing and thawing can damage the integrity of the microbial cells and therefore result in the loss of exposed microbial DNA during host DNA removal.8. To avoid false results due to contamination, keep the work area clean, wear protective clothing, and set up controls for quality control. Use appropriate measures to handle sample materials to minimize the risk of cross-contamination. During the extraction process, use DNA-free pipette tips and consumables, and cap reagents immediately after use to prevent contamination. procedure1. Sample pre-treatment: 1a: For swab samples, swirl the swab portion of the swab in 0.5 ml PBS for at least 20 s. Squeeze the swab several times against the wall of the tube before removing it so that as much of the bacterial fluid as possible can be squeezed out of the swab to minimize sample loss. 1b: For viscous samples, e.g. sputum, take ~500 µl of sample, add 1.5 times the volume (~750 µl) of Buffer GB1 and incubate at 37°C, 600 rpm for 15-30 min until the sample is completely liquefied.Note: The sample volume can be increased or decreased appropriately and the amount of Buffer GB1 added adjusted accordingly.1c: For alveolar lavage fluid containing a small amount of viscous sputum, centrifuge as much of the alveolar lavage fluid as possible, carefully remove the supernatant, and retain the lower viscous fraction (containing sputum, cells, and organisms), add 1.5 times the volume of Buffer GB1, and incubate for 15-30 min at 37°C, 600 rpm until the sample is completely liquefied.1d: For non-viscous body fluid samples such as blood and cerebrospinal fluid, liquefaction treatment is not required, and an appropriate amount of sample is taken directly, the operation of step 2 is carried out, and the cell precipitate is collected by centrifugation.2. Centrifuge at 10000 rpm for 5-10 min at room temperature and carefully discard the supernatant.Note: Do not disturb the lower cell sediment to avoid sample loss.3. Add 500 µl Buffer GB2, vortex to mix, and incubate at room temperature, 600 rpm for 10 min. 4. Centrifuge at 12000 rpm for 2 min and carefully remove the supernatant.Note: Do not disturb the bacterial precipitate when removing the supernatant to avoid sample loss.5. Add 200 µl of Buffer GB2 to the precipitate, add 2 µl of Benzonase and incubate for 30 min at 37°C, 600 rpm. 6. Centrifuge at 12000 rpm for 2 min, discard the supernatant, add 500 µl of Buffer GB2, vortex and wash the precipitate. Repeat the procedure once.7. Centrifuge at 12000 rpm for 2 min, discard the supernatant, and finally aspirate the residual Buffer GB2 with a small-volume tip. 8. Add 180 µl Lysozyme (10 mg/ml), resuspend the bacterial precipitate and transfer the bacterial resuspension to a Lysis Tube.9. The Lysis Tube is incubated at 37°C, 600 rpm for 20-30 min, then vortexed for 10 min or processed on a thermostatic homogenizer for 10 min at maximum vibration speed (2500-2900 rpm).10. Centrifuge briefly, add 20 µl proteinase K, vortex to mix, add 200 µl buffer GL, vortex to mix, and incubate for 30 min at 56°C, 600 rpm. Note: 1) Do not add Proteinase K directly to Buffer GL.2)For RNA removal, add 4 µl DNase-Free RNase A (100 mg/ml) before adding Buffer GL, shake to mix, and let stand at room temperature for 5-10 minutes.11. Centrifuge at 12000 rpm for 1 min and carefully aspirate the supernatant into a new centrifuge tube. Note: Do not aspirate the glass beads.12. Add 200 µl of anhydrous ethanol, vortex to mix, and centrifuge momentarily to collect the solution to the bottom of the tube. Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.13. Add all of the solution from step 12, including the precipitate, to the Spin Columns DM in the collection tube, or transfer the solution several times if it cannot be added all at once. centrifuge at 12,000 rpm for 1 minute, pour off the waste from the collection tube, and return the column to the collection tube.14. Add 500 µl Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 min, pour off the waste liquid from the collection tube, and put the adsorbent column back into the collection tube.15. Add 500 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube. Note: Step 15 can be repeated once if further improvement of DNA purity is required.16. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the column at room temperature for a few minutes and dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).17. Place the adsorbent column in a new centrifuge tube (supplied), add 50 µl of Buffer GE to the center of the adsorbent column overhang, let stand at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 °C. Attention:1)If the downstream experiments are sensitive to pH or EDTA, sterilized water can be used for elution. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2)Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3)If the final concentration of DNA is to be increased, the DNA eluate obtained in step 17 can be re-spiked onto the adsorbent membrane and step 17 repeated. 4)DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product contentP666142Component200 TStorageP666142ABuffer P160 mLRTP666142BBuffer P260 mLRTP666142CBuffer N380 mLRTP666142DBuffer PB35 mLRTP666142EBuffer PW (concentrate)25 mLRTP666142FBuffer EB30 mLRTP666142GRNase A (10 mg/mL)600 µLRTP666142HSpin Columns DM with Collection Tubes200 EART Product IntroductionThis kit is suitable for extracting 1-5 ml of bacterial solution. Based on the lysis of cells by alkaline lysis method, it adopts a unique silica matrix membrane adsorption technology and reagent formulation, and efficiently and exclusively binds plasmid DNA in solution by centrifugal adsorption columns in a high-salt state, and each adsorption column can adsorb a maximum of 30 µg of plasmid DNA, and removes proteins, genomes, RNAs, and other impurities to the greatest extent possible. The plasmid DNA obtained can be directly used for cell transfection, PCR, digestion, sequencing, ligation and other biological experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. All components can be stably stored in dry, room temperature (15-30℃) environment for 1 year, the adsorption column can be stored at 2-8℃ for a longer period of time, and Buffer P1 with RNase A can be stably stored at 2-8℃ for 6 months.2. Before the first use, add all the RNase A solution into Buffer P1, mix well, and store it at 2-8°C. Before use, leave it at room temperature for a period of time, and then use it after recovering to room temperature.3. Anhydrous ethanol should be added to Buffer PW according to the instructions on the label of the reagent bottle before first use.4. If precipitation is found in Buffer P2, Buffer N3, or Buffer PB before use, the clarification can be restored by water bath at 37℃ for a few minutes (please do not shake Buffer P2 violently).5. Be careful not to touch Buffer P2, Buffer N3 and Buffer PB directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.Procedure1. Take 1-5 ml of the overnight culture and add it to a centrifuge tube (self-prepared), centrifuge for 30 seconds at 13,000 rpm (~16,200×g) to collect the bacterial precipitate, and discard the supernatant as much as possible.2. Add 250 µl of Buffer P1 to the centrifuge tube with the bacterial precipitate (please check that RNase A has been added first), mix well using a pipette or vortex shaker, and suspend the bacterial precipitate.Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect, resulting in low extraction and purity.3. Add 250µl of Buffer P2 to the centrifuge tube and mix gently up and down 4-6 times, mixing well to lyse the organisms, at which point the solution should become clear and viscous.Note: Mix gently, do not shake vigorously to avoid interrupting the genomic DNA and causing the extracted plasmid to be mixed with genomic DNA fragments. This step should take no more than 5 minutes to avoid damage to the plasmid.4. Add 350 µl of Buffer N3 to the centrifuge tube and immediately mix gently up and down for 8-10 times, mixing well so that a white flocculent precipitate should appear. centrifuge at 13,000 rpm for 5 minutes.Note: Buffer N3 should be mixed immediately after addition to avoid localized precipitation.5. Transfer the supernatant obtained in step 4 to the Spin Columns DM that have been loaded into the collection tube, centrifuge at 13,000 rpm for 30 seconds, pour off the waste liquid from the collection tube, and place the column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 30 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 13,000 rpm for 1 minute, and pour off the waste liquid in the collection tube.8. Place the adsorbent column in a new centrifuge tube (supplied), add 50-100 µl Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2 minutes, centrifuge at 13,000 rpm for 1 minute, and collect the plasmid solution into the centrifuge tube. -The plasmid solution was collected into the centrifuge tube.Note: 1) To increase the recovery efficiency of the plasmid, the resulting solution can be reintroduced into the adsorbent column, left at room temperature for 2 minutes, centrifuged at 13,000 rpm for 1 minute, and the plasmid solution collected into a centrifuge tube.2) For low plasmid copy number or >10 kb, Buffer EB is preheated at 65-70°C in a water bath to increase extraction efficiency... Read More |