| Description | A1372286Components20T50T100TStorageA1372286A10X Annexin V Binding Buffer5 mL10 mL20 mL2-8℃A1372286BAnnexin V (FITC)100µL250 µL500 µL2-8℃. Store in the dark.A1372286CPropidium iodide Staining Solution (PI)100µL250 µL500 µL2-8℃. Store in the dark. A1372286Components20T50T100TStorageA1372286A10X Annexin V Binding Buffer5 mL10 mL20 mL2-8℃A1372286BAnnexin V (FITC)100µL250 µL500 µL2-8℃. Store in the dark.A1372286CPropidium iodide Staining Solution (PI)100µL250 µL500 µL2-8℃. Store in the dark. Background informationAnnexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner.In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative).This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry.Precautions1. Please try to avoid light when using to slow down the quenching of fluorescence.2. Propidium Iodide Solution is toxigenic and mutagenic; handle with care.3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments.Instruction for use1. Dilute 10X Binding Buffer to 1X using distilled water (1 mL 10X Binding Buffer + 9 mL ddH2O).2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 1.0-5.0 x 106 cells/mL.3. Add 5 µl of FITC Annexin V and 2 µl PI to 100 µL of the cell suspension4. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.5. Add 100 µl of 1X Binding Buffer to each assay. Analyze by flow cytometry within 1 hr... Read More | Product Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 andProduct Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 and α1-4 fucosyl linkages in these substrates without the need to remove sialic acid moieties.For removing core fucose linked α-(1-6) to the core GlcNAc of a GlcNAc-GlcNAc disaccharide structure we recommend our Alpha-(1-6) Fucosidase.• Non-sialidase dependant hydrolysis of antennary fucose moieties• Effective on both glycopeptides and free glycans• Highly specific (α1-3,4 fucosylated glycans)• Kit includes enzyme plus reaction buffer.• Sufficient for up to 50 samplesα(1-3,4) Fucosidase is useful for:nbsp;nbsp;Fucose linkage determinationnbsp;nbsp;Deglycosylating glycoproteins with Lewis structuresContentsAlpha-(1-3,4)-Fucosidase – 200 mM citrate buffer pH 6 containing 250 mM NaCl5x Reaction Buffer – 250 mM sodium phosphate pH 6... Read More | Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Product introduction:Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Instruction: Experimental materials ( self-provided ):①cell lines or other cell samples ( self-prepared ) ;②This kit ; ③ trypsin ( self-prepared ) ;④ Cell culture medium containing FBS ( self-prepared ) ; Experimental procedure: 1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. ( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. ( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 2.Staining : 4 µL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.Scope of application:Cell cycle detection... Read More | Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× Products contentN665954Component24 T96 TStorageN665954ATPS V136 µL144 µL-20℃. Avoid freeze/thaw cycle.N665954B5×FA Reaction Buffer96 µL384 µL-20℃. Avoid freeze/thaw cycle.N665954CTS Buffer72 µL288 µL-20℃. Avoid freeze/thaw cycle.N665954D2× PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle. * This kit is suitable for human genomic DNA library construction, the starting template DNA input amount is 1 ng, our company also has 50 ng and 5 ng of human genomic DNA starting transposase method library construction kit, in order to get a higher quality library, different starting amount of DNA is recommended to use different kits. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for use with 1 ng of starting template DNA, and all reagents in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction.Product Features● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification preference.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kit: It is recommended to use Kangwei transposase method for second generation sequencing multi-sample primer kit.4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing. Sample PreparationDNA purity requirement: A260/A280 = 1.8-2.0. Sample DNA: dissolved in ultrapure water.DNA quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification). Schematic diagram of DNA banking process procedureDNA fragmentation, junction reaction 1. Add the following reagents to a 200 µl PCR tube:2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:inactivation reactionAfter the DNA is fragmented, the enzyme is still in a high active state, so it should be removed from the PCR instrument immediately and terminated by adding the Reaction Termination Buffer, in order to prevent the DNA from being fragmented too much and resulting in smaller library fragments.1. Add 3 µl of TS Buffer to the PCR tube containing the fragmentation product.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Incubate at room temperature for 5 min, or if the room temperature is too low, place the reaction on a PCR instrument at 25°C with the thermal cover closed.PCR amplification1. Add the following reagents to a 200 µl PCR tube.2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube. 3. Place the above PCR tubes in the PCR instrument with the thermal cap open, and the reaction program is as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads used is different, please refer to the attached table for the specific amount of magnetic beads used.(If using other brands of magnetic beads, you need to figure out the optimal amount of magnetic beads by yourself).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, amplification products can also be purified directly from DNA fragments without selective recovery of DNA fragments as described on page 4 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR products to a 1.5 ml centrifuge tube, rehydrate to 100 µl, add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds, and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Kangwei Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube. Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library.Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Inquire |