| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner. In early-stage apoptosis, the plasma membrane excludes viability dyes such as 4',6-diamidino-2-phenylindole (DAPI), propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative). This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry.A1456534Components20 T50 T100 TStorageQuantity Per TestA1456534A10× Annexin V Binding Buffer5 mL10 mL20 mL2-8℃200 µL 0.5-1.0 × 10⁵ cellsA1456534BAnnexin V -APC100 µL250 µL500 µL2-8℃. Store in the dark.5 µL 0.5-1.0 × 10⁵ cellsA1456534CDAPI Staining Solution (25 µg/mL)20 µL50 µL100 µL2-8℃. Store in the dark.1 µL 0.5-1.0 × 10⁵ cellsNote: The recommended number of cells to stain per test is 0.5-1.0 × 10⁵ cells.Precautions1. Please try to avoid light when using to slow down the quenching of fluorescence.2. DAPI Solution is toxigenic and mutagenic; handle with care.3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments.Instruction for use 1. Dilute 10X Binding Buffer to 1X using distilled water (1 mL 10X Binding Buffer + 9 mL ddH2O).2. Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 0.5- 1.0 × 10⁶ cells /mL.3. Add 5 µL of Annexin V-APC and 1 µL of DAPI staining solution to 100 µL of cell suspension.4. Add 100 µLof 1x Binding Buffer to each assay. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.5. Analyze by flow cytometry within 1 hr... Read More | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | Format:2-ComponentEnzyme:Horseradish peroxidase | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More | This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover This kit combines efficient guanidine isothiocyanate lysis technology with silicon matrix membrane purification technology to efficiently extract total RNA from animal cells and tissues. The starting sample usually has a maximum of 30 mg of tissue or 1 x 107 cells. This reagent kit can also recover partially purified RNA, RNA obtained from in vitro transcription and enzymatic reactions. This reagent kit can extract and purify high-quality RNA with a molecular weight greater than 200 bases, with almost no DNA residue. If RNA experiments are to be conducted that are highly sensitive to trace amounts of DNA, residual DNA can be digested and removed on a column using DNase I without RNase. The extracted RNA can be used for downstream experiments such as RT-PCR, Northern Blot, Dot Blot, etc. R666020Component50 TStorageR666020ABuffer RL35 mLRTR666020BBuffer RW140 mLRTR666020CBuffer RW2 (concentrate)11 mLRTR666020DRNase-Free Water10 mLRTR666020ESpin Columns RM with Collection Tubes50 setsRTR666020FRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: β- Mercaptoethanol, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of RNA extraction.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be heated at 56 ℃ and re solved. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.6. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.Operation steps1. Sample processing1a organization: Grind the organization in liquid nitrogen. Add 600 to every 20-30 mg of tissue µ L Buffer RL (check if it is added before use) β- Mercaptoethanol), tissue sample less than 20 mg plus 350 µ Buffer RL. The sample volume shall not exceed one tenth of the buffer RL volume.1b Single layer culture of cells: The cells are directly lysed or processed into cell suspensions in a culture bottle, centrifuged to obtain cell precipitates, and the supernatant is discarded. 600 is added every 6-10 cm2 of culture area µ Buffer RL, less than 6 cm2, add 350 µ Blow buffer RL several times to fully crack it.1c cell suspension: Centrifuge at 12000 rpm (~13400 × g) for 1 minute to discard the supernatant and obtain cell precipitate. Add 600 cells every 5 × 106-1 × 107 cells µ Buffer RL, less than 5 × 106 cells added to 350 µ Blow buffer RL several times to fully crack it.Attention:1) Try to eliminate the cell culture medium as much as possible, as it may inhibit cell lysis and affect RNA production.2) Try to fully suspend and lyse the cells, otherwise it will affect RNA production.2. After the sample is fully lysed, it should be left at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Centrifuge at 2000rpm for 2-5 minutes, take the supernatant and proceed to the next step.4. Add 1 volume (600) µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.5. Add all the solution obtained in step 4 to the Spin Columns RM that has been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube. Attention: The maximum loading capacity of the adsorption column is 100 µ g, do not overload, otherwise it will affect the yield and purity of RNA.6. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column in the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 6 with the following steps.1) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.2) Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1 U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 15 seconds, discard the waste liquid, and place the adsorption column back into the recovery manifold.7. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.8. Repeat step 7. 9. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column in a new RNase free centrifuge tube, and add 30-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 10 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 10... Read More |