| Description | Free Fatty Acids (FFA), also known as Non-Esterified Fatty Acids (NEFA), are primarily produced by the hydrolysis of neutral fats. They are intermediate products in fat metabolism, involved in cell proliferation, inflammatory responses, and hormone regulation. FFA can also act as signaling moleculesFree Fatty Acids (FFA), also known as Non-Esterified Fatty Acids (NEFA), are primarily produced by the hydrolysis of neutral fats. They are intermediate products in fat metabolism, involved in cell proliferation, inflammatory responses, and hormone regulation. FFA can also act as signaling molecules with various physiological functions. Free fatty acids are closely related to lipid metabolism, glucose metabolism, and endocrine function. Their concentration is an important physiological and biochemical indicator, serving as an auxiliary parameter for disease evaluation and diagnosis, and also reflecting quality changes during food storage.Detection Principle: FFAs combine with copper ions to form copper soaps, which are soluble in chloroform. The copper ions can then react with a chromogenic solution to form a purplish-red complex. This product has a characteristic absorption peak at 550 nm. The FFA content can be quantified by measuring the change in absorbance.Detection Range: 0.0313 - 2 mMSensitivity: 0.0156 mMApplicable Samples: Serum (plasma), animal/plant tissues, cells, bacteria.A1492746Component48T96TStorageA1492746ACu Reagent6 mL12 mL2-8℃. Store in the dark.A1492746BChromogen15 mL30 mL2-8℃. Store in the dark.A1492746CStandard (16.41 mg Palmitic Acid)1 EA1 EA2-8℃. Store in the dark.User-Prepared Instruments and ReagentsMicroplate reader or visible spectrophotometer (capable of measuring absorbance at 550 nm)Incubator, Ice maker, Low-temperature centrifuge96-well plate or micro glass cuvettes, Adjustable pipettes and tipsHomogenizer (for tissue samples)Glass bottle (for preparing extraction buffer)n-Heptane, Anhydrous methanol, ChloroformExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationPrecautionsExtraction Buffer (Self-prepared)In a glass bottle, mix Chloroform : n-Heptane : Anhydrous Methanol = 28 : 21 : 1. Cap tightly and mix well.Store at 4°C protected from light.Cu ReagentReady-to-use; equilibrate to room temperature before use; mix well before use.Store at 4°C protected from light.ChromogenReady-to-use; equilibrate to room temperature before use.Store at 4°C protected from light.StandardBefore use, dissolve contents in 1 mL of Extraction Buffer to obtain a 64 mM Standard solution. Mix well.Unused dissolved Standard can be stored in a tightly sealed glass bottle at 4°C protected from light for 1 month.2. Standard Curve SetupDilute the 64 mM Standard further with Extraction Buffer as shown in the table below.Standard No.Standard (µL)Extraction Buffer Volume (µL)Standard Concentration (mM)Std.120µL of 64mM stock6202Std.2100µL of Std.11001Std.3100µL of Std.21000.5Std.4100µL of Std.31000.25Std.5100µL of Std.41000.125Std.6100µL of Std.51000.0625Std.7100µL of Std.61000.0313Note: Prepare freshly diluted standards for each experiment.3. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for up to 6 months.3.1 Animal Tissues: Weigh approximately 0.1 g of tissue, add 1 mL of Extraction Buffer, and homogenize on ice. Centrifuge at 8,000 rpm, 4°C for 10 min. Collect the supernatant and keep on ice for detection.3.2 Plant Tissues: Weigh approximately 0.1 g of tissue, add 1 mL of Extraction Buffer, and grind. Disrupt by ultrasonic homogenization on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 8,000 rpm, 4°C for 10 min. Collect the supernatant and keep on ice for detection.3.3 Cells or Bacteria: Collect 5 million cells or bacteria into a centrifuge tube. Wash with cold PBS, centrifuge, and discard the supernatant. Add 1 mL of Extraction Buffer. Disrupt by ultrasonic homogenization on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 7 s, repeat 30 times). Centrifuge at 8,000 rpm, 4°C for 10 min. Collect the supernatant and keep on ice for detection.3.4 Serum (Plasma) and other liquids: Detect directly.4. Assay Steps4.1 Instrument Preparation: Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 550 nm. For spectrophotometers, zero the instrument with deionized water.4.2 Sample Assay (Add reagents sequentially to EP tubes):ReagentBlank Tube (µL)Standard Tube (µL)Test Tube (µL)Extraction Buffer240200200Various Std.0400Sample0040Cap the tubes tightly and vortex at medium speed for 30 seconds.Cu Reagent808080Cap the tubes tightly and vortex at medium speed for 30 seconds. Incubate at room temperature (25°C) for 20 minutes. Centrifuge at 2,000 g, room temperature (25°C) for 5 minutes.Upper Phase505050Chromogen2002002004.3 Incubate at room temperature (25°C) for 5 minutes. Transfer 200 µL from each tube to the corresponding wells of a 96-well plate or micro glass cuvettes. Measure the absorbance at 550 nm.Calculate ΔAtest=Atest-Ablank and ΔAstd=Astd-Ablank (The blank tube only needs to be set up once).Note: The measurement must be completed within 30 minutes after color development. It is recommended to perform preliminary experiments with 2-3 samples expected to have significant differences before formal testing. If Atest exceeds the detection range of the instrument, dilute the sample further with Extraction Buffer and multiply the result by the dilution factor.5. Result CalculationWe provide both derived and simplified calculation formulas, which are equivalent. The simplified formulas in bold are recommended as the final calculation formulas.5.1 Standard Curve PlottingPlot the standard curve with standard concentration as the y-axis and ΔAstd as the x-axis (using concentration as the y-axis facilitates calculation). Substitute ΔAtest into the standard curve equation to obtain y (mM).5.2 Sample FFA Content Calculation(1) Based on sample mass:FFA Content (µmol/g fresh weight) = y × Vextract ÷ W × n = y ÷ W × n(2) Based on bacterial or cell count:FFA Content (µmol/10⁴ cells) = y ÷ (Cell or Bacterial Count ÷ Vextract ) × n = y ÷ 500 × n = 0.002 × y × n(3) Based on liquid volume:FFA Content (µmol/L) = 1000 × y × nParameter Description:Vextract : Volume of Extraction Buffer added, 1 mLW: Sample mass, gn: Sample dilution factor (if further diluted)500: Cell or bacterial count, in units of 10⁴1000: Unit conversion factor, 1 L = 1000 mL6. Result PresentationTypical Standard Curve: y = 0.679x - 0.0109, R² = 0.9988(Free Fatty Acid (FFA) standard curve analyzed using a 96-well plate. Data and curve are for reference only; users must establish their own standard curve based on their experiment.)Precautions1. Biochemical reagents are generally irritating and biologically toxic. For your safety and health, please implement appropriate biosafety precautions throughout the experiment. Wear personal protective equipment such as lab coats, masks, gloves, and hair caps. Perform experiments in a fume hood or biosafety cabinet.2. This product is for scientific research use only. Not intended for clinical diagnosis... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 Product content: S665546Component50 TStorageS665546ABuffer QSL45 mLRTS665546BBuffer RIL11 mL2-8℃S665546CBuffer ML10 mLRTS665546DBuffer GW1 (concentrate)13 mLRTS665546EBuffer GW2 (concentrate)26 mLRTS665546FBuffer EBL13 mLRTS665546GRNase A240 µLRTS665546HLysis Tubes Ⅱ50 EARTS665546ISpin Columns DM With Collection Tubes50 EARTProduct IntroductionThis kit provides a method for extracting total DNA from soil or fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples. It is also suitable for extracting DNA from samples containing high concentrations of PCR reaction inhibitors. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as second-generation sequencing (16S amplicons and metagenomes), library construction, PCR, qPCR, Southern Blot, enzyme digestion molecular markers, etc.Self prepared reagents1. Constant temperature mixer - Product number: CW25932. Anhydrous ethanol, isopropanol3. Vortex oscillator or tissue grinderPreparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 (concentrate) and Buffer GW2 (concentrate) according to the instructions on the reagent bottle label.3. Take out the buffer RIL before use and store it at 2-8 ℃ immediately after use.Operation steps1. Centrifuge the Lysis Tube briefly to allow the beads to settle at the bottom.2. a. Add 0.1-0.3 g of soil or fecal sample to Lysis Tube, and add 740-820 µ L Buffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.b. If fecal samples are stored in non lytic fecal preservation solutions (such as CWY041S and CWY041M), add 200 to Lysis Tube µ L-600 µ L solid-liquid mixture, centrifuge at 13000 rpm for 1 minute, discard the storage solution (if the amount of solid after centrifugation is too small, it can be enriched again, but should not exceed 0.3g). Join 620 µ LBuffer QSL and 4 µ L RNase A, tighten the tube cover and briefly vortex to mix.3. Fix the Lysis Tube in an oscillating grinding device equipped with a 2 mL adapter and process it according to the optimized grinding conditions of your equipment (see appendix).4. Shake the Lysis Tube on a constant temperature mixer at 70 ℃ and 1200 rpm for 10 minutes. Subsequently, centrifuge at 13000 rpm for 2 minutes to precipitate solid particles. Transfer 540 µ Transfer the supernatant to a new 2 mL centrifuge tube.5. Add 180 µ L Buffer RIL, vortex for 5 seconds, centrifuge at 13000 rpm for 2 minutes.Attention: Remove the buffer RIL before use and store it at 2-8 ℃ immediately after use.6. Add 160 to the new centrifuge tube in sequence µ L Buffer ML, 480 µ Supernatant from step 5, 320 µ L isopropanol, vortex for 5 seconds.7. Transfer the solution from the previous step to 650 µ Centrifuge at 12000 rpm (~13400 × g) for 1 minute into the spin columns DM that have been loaded into the collection tube.8. Discard the waste liquid in the collection pipe and place the adsorption column back into the collection pipe. Repeat step 7 until all the solution has been transferred.9. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 11. Repeat step 10.12.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new centrifuge tube (self provided) and add 50-200 drops of suspended droplets to the middle of the adsorption column µ L Buffer EBL or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) Incubating at room temperature for 5 minutes before centrifugation can increase yield.2) Use an additional 50-100 µ Further elution with L buffer or sterilized water can increase yield.3) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 13 back onto the adsorption membrane and repeat step 13, but it may reduce the total yield.4) The elution buffer does not contain chelating agents, please store DNA at -20 ℃.5) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can usually be resolved by diluting the DNA by 2-10 times.Appendix: Grind the sample using one of the following methods1. Manually vortex oscillate at maximum speed on the vortex oscillator for 10 minutes.2. On a vortex oscillator equipped with a 1.5-2 mL horizontal centrifuge tube holder, oscillate at maximum speed for 10 minutes (keeping the Lysis Tube horizontal). If the sample size exceeds 12, extend by 5-10 minutes. For example, using Scientific Industries or Mobile's Vortex Genie2 vortex oscillator.3.When using Qiagen's TissueLyser II, grind at 25Hz for 10 minutes.4.When using Qiagen's PowerLyzer 24 Homogenizer, homogenize at 2000 rpm for 30 seconds, pause for 30 seconds, and then homogenize again at 2000 rpm for 30 seconds.5.When using FastPrep-24 from MP Biomedicals, the recommended speed is 6.0 and the time is 40 seconds... Read More |