| Description | Inquire | Store at -20°C. Please refer to protocols | The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of total RNA. This product combines phenol/guanidine lysis technology and silicon matrix membrane purification technology. The unique lysis solution can effectively inhibit RNases while removing most of DNA and proteins from cell or tissue samples through organic extraction. For some sensitive downstream experiments, if miRNA enrichment is required, this kit can be used to enrich miRNA separately. This product is suitable for a wide range of samples, with high purity of prepared RNA, and can be directly used for sensitive downstream applications, such as Northern Blot analysis, Real Time PCR, Microarray Analysis, etc. M665531Component50 TStorageM665531ATRIzon Reagent60 mL2-8℃. Protect from ligt.M665531BBuffer RWT (concentrate)15 mLRTM665531CBuffer RW2 (concentrate)11 mLRTM665531DRNase-Free Water10 mLRTM665531ESpin Columns RM with Collection Tubes50 setsRTM665531FSpin Columns RS with Collection Tubes50 setsRTM665531GRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: chloroform, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of miRNA extraction.Before the first use, anhydrous ethanol should be added to Buffer RWT and Buffer RW2 according to the instructions on the reagent bottle label.4. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps:Protocol A: miRNA enrichment (can be directly used for sensitive downstream experiments)1. Sample processing1a Organization: Grind the organization in liquid nitrogen. Add 1 ml of TRIzon Reagent to every 30-50 mg of tissue, shake and mix well. The sample volume shall not exceed one tenth of the volume of TRIzon Reagent.1b Single layer culture of cells: Remove the culture medium, add TRIzon Reagent, and add 1 ml of TRIzon Reagent every 10 cm2 (the amount of lysis solution depends on the area of the culture bottle).1c Cell suspension: Centrifuge to obtain cell precipitate, discard supernatant. Add 1 ml of TRIzon Reagent to every 5 x 106-1 x 107 cells (cells do not require washing).1d Plasma or serum: Take 200 µ Add 5 times the volume of TRIzon Reagent to plasma or serum samples, shake and mix well for 30 seconds.2. After adding TRIzon Reagent to the sample, blow it repeatedly several times to fully crack it. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Optional steps: Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 5 minutes, take the supernatant, and transfer it to a new centrifuge tube (provided by oneself) (if the sample contains more proteins, fats, polysaccharides, etc., this step can be performed).4. Add chloroform to the supernatant and add 200 to every 1 ml of TRIzon Reagent used µ Chloroform, cover the tube, vigorously shake for 15 seconds, and let it sit at room temperature for 5 minutes.Centrifuge at 5.4 ℃ and 12000 rpm for 15 minutes. The sample is divided into three layers: red organic phase, middle layer, and colorless aqueous phase. Transfer the upper colorless aqueous phase to a new centrifuge tube (self prepared).6. Add 1/3 volume of anhydrous ethanol to the solution obtained in step 5, mix well, and transfer the obtained solution and precipitate together into the adsorption column RM (Spin Columns RM) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the adsorption column RM after centrifugation, and retain the effluent.7. Add 2/3 times the volume of anhydrous ethanol to the solution obtained in step 6 and mix well.8. Transfer the solution and precipitate obtained from the previous step into the adsorption column RS (Spin Columns RS) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.9. Add 700 to the adsorption column RS µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.10. Add 500 to the adsorption column RS µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.11. Repeat step 10.12. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RS at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column RS, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column RS in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RS and repeat step 13Protocol B: Extraction of total RNA (including miRNA and other small molecule RNAs<200 nt), steps 1-5 are the same as protocol A.6. Add 1.25 times the volume of anhydrous ethanol to the solution obtained in step 5 and mix well.7. Transfer the solution and precipitate obtained from the previous step into the spin columns RM that have been loaded into the collection tube. If you cannot add all the solution to the adsorption column RM at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.8. Add 700 to the adsorption column RM µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.9. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.10. Repeat step 9.11. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RM at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column RM, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Transfer the adsorption column RM into a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation. Attention: 1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RM and repeat step 12... Read More | This plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yieldThis plant protein extraction kit can extract soluble plant proteins from fresh, frozen, or dried plant tissues. Suitable for protein extraction from various plants and different parts of plants (such as roots, stems, leaves, flowers, seeds, etc.), with high extraction efficiency, high protein yield, high activity, and fast speed. The extracted protein can be directly subjected to protein electrophoresis analysis, immunoprecipitation, Western Blot, protein activity determination, and protein purification experiments. The concentration of the extracted protein can be determined using the BCA protein quantification kit. P665757Component100 TStorageP665757APlant Protein Extraction Reagent100 mLRTP665757BProtease Inhibitor Cocktail (100×)1 mL-20℃. Avoid freeze/thaw cycle. Precautions:1. This product contains 1mM EDTA.2. To prevent protein degradation, all operations should be carried out on ice as much as possible.3. After extracting protein using this product, the BCA method can be used for protein quantification.4. To achieve the best experimental results, please adjust the optimal usage amount according to the experiment.Operation steps:1. Please remove the required Plant Protein Extraction Agent for pre cooling before protein extraction.2. Weigh the weight of the experimental plant tissue. Add 5 ml of Plant Protein Extraction Agent to 1 g of tissue (add Protein Inhibitor Cocktail in a 1:99 ratio before protein extraction).Attention:1) Before homogenization, cut large pieces of plant tissue into small pieces and homogenize them with a mechanical homogenizer for 10 seconds, with an interval of 10 seconds. Repeat the process three times and select the appropriate homogenization method according to the different tissue samples.2) The amount of lysate used is adjusted according to different parts of the plant. If concentrated protein extracts are needed, the amount of Plant Protein Extraction Agent used can be appropriately reduced.3. After homogenization, incubate on ice for 20-30 minutes.4.4 ℃ 13400 × g, centrifuge for 20 minutes.5. Collect soluble proteins from the supernatant for further purification or downstream analysis... Read More | The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This The commonly used method of eukarYOtic gene expression regulation research is the detection of reporter genes, and bioluminescence is the most commonly used and effective means of reporter gene detection. Luciferase can catalyze the conversion of the substrate luciferin and emit photons. This product provides a rapid, sensitive and stable detection method for the expression of Renilla luciferase reporter gene in mammalian cells. Product characteristic:1.Rapid : Cell lysis was completed within 10-15 min ;2.Convenience : The reagent is easy to prepare, and the sample detection steps are simple;Instruction:1. Cell lysis ( 1 ) Remove the culture medium and gently wash with PBS ( adherent cells can be directly performed this operation, suspension cells should be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products after full pyrolysis were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was moved into a new EP tube for subsequent detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C into renilla luciferase working solution with component B, and the dilution method is to add 1 µL C component to 49 µL B component. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) The cell lysis products were added to the measuring tube according to the volume of 20 ~ 100 µL ( keep the same amount of samples each time ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL renilla luciferase working solution was added to determine the RLU ( Relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). Note : The renilla luciferase working solution cannot be stored for a long time. It is now ready for use and is used once. Component:RenillaLuciferase Lysis Buffer;RenillaLuciferase Assay Buffer;CoelenterazineMatters needing attention:Scope of application: Matters needing attention:1.Please instantaneously centrifuge the product to the bottom of the tube before use, and then carry out subsequent experiments ; 2.Due to the influence of temperature on the enzyme reaction, the sample and reagent should be measured after reaching room temperature. 3.The strongest wavelength of bioluminescence catalyzed by renilla luciferase is 480 nm, in order to prevent interference between holes, it is recommended to use white opaque orifice plate ;4. B component is recommended to carry out small batch packing according to the experimental requirements ; 5.It is recommended to use it now to avoid repeated freezing and thawing ; 6.For your safety and health, please wear experimental clothes and wear disposable gloves. Scope of application:Study on gene expression regulation and promoter... Read More |