| Description | ECL Basic Chemiluminescence Detection Kit (Pico-grade) is a non-radioactive chemiluminescence system designed for detecting the activity of horseradish peroxidase (HRP) conjugated to membrane-bound proteins. This product contains an enhanced luminol substrate and a stable peroxide solution, enablingECL Basic Chemiluminescence Detection Kit (Pico-grade) is a non-radioactive chemiluminescence system designed for detecting the activity of horseradish peroxidase (HRP) conjugated to membrane-bound proteins. This product contains an enhanced luminol substrate and a stable peroxide solution, enabling the detection of trace amounts of protein as low as the pico-gram level. It is suitable for routine Western Blot chemiluminescence detection.Component ListComponent100 mL500 mLStorageE1491297AECL PicoLight Substrate50 mL250 mL2-8℃. Store in the dark.E1491297BECL PicoLight Oxidant50 mL250 mL2-8℃. Store in the dark.FeaturesHigh Sensitivity – Capable of rapidly detecting proteins at pico-gram levels, outperforming other high-end products in the same category.High Cost-Effectiveness – Offers exceptional value compared to other chemiluminescence substrates of similar grade.Instructions for UseRemove the transfer membrane from the washing buffer and drain any excess liquid, keeping the membrane moist.Mix PicoLight ECL Substrate and Oxidant in equal volumes to prepare the chemiluminescence working solution (approximately 0.1 mL per square centimeter of membrane).Apply the working solution evenly onto the membrane and incubate for 1–2 minutes. For strong target protein signals, avoid letting the working solution remain static. Gently agitate the membrane on a shaker for 1–2 minutes to prevent local depletion of reactants, which may affect the linear detection range.Remove the membrane and drain any excess working solution. Wrap it in a transparent protective cover.X-ray Film Exposure: In a darkroom, expose the membrane to X-ray film. Exposure times may vary from seconds to minutes. Develop the film and adjust exposure time for repeat imaging if necessary.CCD Imager: The membrane can be directly imaged without a protective cover. Follow the manufacturer’s instructions for image capture.The membrane can be stripped and reprobed for multiple hybridizations.PrecautionsProtect PicoLight ECL Substrate and the working solution from strong light to avoid reduced sensitivity.Due to the high sensitivity of the solution, avoid using overly concentrated antibodies to prevent high background signals.Sodium azide (NaN₃) inhibits HRP activity. Do not use NaN₃ for storing or reusing secondary antibodies.Wear a lab coat and disposable gloves for personal safety.This product is for research use only... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More |