| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial Product introduction:This kit uses an improved SDS alkaline lysis method combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of rapid purification of plasmid DNA. It is suitable for extracting up to 500ug of high-purity plasmid DNA from 120-300ml bacterial culture for sequencing, in vitro transcription and translation, restriction enzyme digestion, bacterial transformation and other molecular biology experiments.Scope of application:Nucleic acid extraction and purification... Read More | This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be completed simultaneously within 1 hour. This product does not require the ultra centrifugation step of CsCl purification and LiCl or ethanol precipitation. It does not contain toxic solvents such as phenol or chloroform. The purified RNA effectively removes enzyme inhibitors and pollutants such as heme and heparin. It can be directly used in various molecular biology routine experiments, such as RT-PCR, Northern Blot, Dot Blot, in vitro translation, and so on.Self prepared reagents: β- Mercaptoethanol, 70% ethanol (prepared with water without RNase), anhydrous ethanol. R666034 Component 50 T Storage R666034A Buffer RBL (10×) 60 mL RT R666034B Buffer RL 35 mL RT R666034C Buffer RW1 40 mL RT R666034D Buffer RW2 (concentrate) 11 mL RT R666034E RNase-Free Water 10 mL RT R666034F Spin Columns FL with Collection Tubes 50 sets RT R666034G Spin Columns RM with Collection Tubes 50 sets RT R666034H RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RT Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be dissolved again in a 56 ℃ water bath. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. This reagent kit cannot be used for RNA extraction from frozen blood samples with anticoagulants added.6.10 × Buffer RBL needs to be diluted 10 times with water without RNase before use, and then stored at 2-8 ℃ after dilution.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.8. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Add 5 times the volume of 1 x Buffer RBL to fresh anticoagulant whole blood samples of 0.5-1.5 ml (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex or invert and mix well. Incubate on ice for 10-15 minutes, mix twice during the incubation process.Attention: During the incubation process, the cloudy suspension will become transparent, indicating that red blood cells have been lysed. If necessary, the incubation time can be extended to 20 minutes. 2. Centrifuge at 4 ℃, 2100 rpm (~400 × g) for 10 minutes, and carefully discard the supernatant.3. Add 2 times the volume of the blood sample to the above precipitate with 1 x Buffer RBL (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex, and resuspend the precipitate thoroughly. 4. Centrifuge at 4 ℃ and 2100 rpm for 10 minutes, carefully and thoroughly remove the supernatant.Note: This step must completely remove the supernatant, otherwise it will affect the lysis and lead to a decrease in RNA production.5. Add Buffer RL to the precipitate (check if it has been added before use β- Mercaptoethanol, 0.5-1.5 ml of blood sample added to 600 µ L Buffer RL, or less than 0.5 ml of blood sample added to 350 µ L Buffer RL, mix well.6. Transfer the obtained liquid to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, collect the filtrate, and discard the filter column.7. Add 1 volume (600) to the obtained filtrate µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.8. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 9 with the following steps.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Repeat step 10. 12. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 13... Read More | Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 Product Content R669990Component50 TStorageR669990ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669990B10×Reaction Buffer1 mL-20℃. Avoid freeze/thaw cycle.R669990CBuffer RL35 mLRTR669990DBuffer RW135 mLRTR669990EBuffer RW2 (concentrate)11 mLRTR669990FRNase-Free Water10 mLRTR669990GSpin Columns RM with Collection Tubes50 setsRTR669990HRNase-Free Centrifuge Tubes (1.5 mL)50 EART ProductsThis kit combines highly efficient guanidine isothiocyanate cleavage technology with silica matrix membrane purification for the efficient extraction of total RNA from animal cells and tissues, typically up to 30 mg of tissue or 1x107 cells as a starting sample. The kit also allows recovery of incompletely purified RNA, in vitro transcription and RNA from enzymatic reactions. high quality RNA with molecular weights greater than 200 bases can be extracted and purified using the kit with virtually no DNA residue. If RNA experiments that are very sensitive to trace DNA are to be performed, residual DNA can be removed by on-column digestion using RNase-free DNase. The extracted RNA can be used in downstream experiments such as RT-PCR, Nothern Blot and Dot Blot. Self-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction).Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips to avoid cross-contamination.2) RNase-free water should be used to prepare the solution.(3) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the amount and quality of RNA extraction.3. Please add β-mercaptoethanol to Buffer RL before use, add 10µl of β-mercaptoethanol to 1ml of Buffer RL. Buffer RL with β-mercaptoethanol can be stored for 1 month at room temperature.4. Anhydrous ethanol should be added to Buffer RW2 before first use according to the instructions on the reagent bottle label.5. Buffer RL may be heated at 56°C to dissolve if precipitation occurs and then left at room temperature.All centrifugation steps are performed at room temperature and all maneuvers are performed quickly.Procedure1. Sample handling1a Tissue: Grind tissue in liquid nitrogen. Add 600 µl Buffer RL for every 20-30 mg of tissue (check for addition of β-mercaptoethanol before use), and 350 µl Buffer RL for tissue samples of less than 20 mg. Sample volume is not to exceed one-tenth of the Buffer RL volume.1b Cells in monolayer culture: Lysed or processed into cell suspension directly in culture flask, centrifuged to obtain cell precipitate, discarded the supernatant, added 600µl Buffer RL for every 6-10 cm2 of culture area, 350µl Buffer RL for less than 6cm2, and blown several times repeatedly to make the cells lysed sufficiently.1c Cell suspension: centrifuge at 12,000 rpm (~13,400 × g) for 1 min and discard the supernatant to obtain the cell precipitate. Add 600 µl Buffer RL for every 5×106-1×107 cells, and 350 µl Buffer RL for less than 5×106 cells, and blow several times repeatedly to fully lysate.Note: 1) Try to get rid of the cell culture medium, which may inhibit cell lysis affecting RNA yield.2) Try to keep the cells well suspended and well lysed, otherwise RNA yield is affected.2. After the sample is fully lysed, leave it at room temperature for 5 minutes to allow complete separation of the protein-nucleic acid complex.3. Centrifuge at 12,000 rpm for 2-5 min and remove the supernatant for the following operations.4. Add 1x volume (600µl or 350µl) of 70% ethanol (prepared without RNase water) to the solution obtained in step 3 and mix well.Note: The addition of ethanol may produce a precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in the previous step to the Spin Columns RM in the collection tube. If you cannot add all of the solution to the column at once, transfer it in two passes, centrifuge at 12,000 rpm for 1 minute, and discard the waste solution. Place the column back into the collection tube.Note: The maximum loading capacity of the adsorption column is 100µg, do not overload as this will affect the yield and purity of the RNA.6. Add 350 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.7. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water, add 8 µl of 10×Reaction Buffer and 20 µl of DNase I (1 U/µl) to it, mix well, and prepare a final volume of 80 µl of reaction solution.8. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.9. Add 200 µl Buffer RW1 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, discard the waste liquid and put the adsorbent column back into the collection tube.10. Add 500µl Buffer RW2 to the column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.11. Repeat step 10.12. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for a few minutes to thoroughly dry the anhydrous ethanol in the adsorption column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).13. Transfer the adsorbent column into a new centrifuge tube, add 30-50 µl of RNase-Free Water to the middle of the adsorbent membrane, leave it at room temperature for 1 min, centrifuge at 12,000 rpm for 1 min, collect the RNA solution, and store the RNA at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Wate should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 13 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 13 repeated... Read More |