| Description | Inquire | B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets B669951 Component 50T Storage B669951A Buffer ATL 15 mL RT B669951B Buffer AL 15 mL RT B669951C Buffer AW1 (concentrate) 13 mL RT B669951D Buffer AW2 (concentrate) 15 mL RT B669951E Buffer EB 15 mL RT B669951F Proteinase K 1.25 mL RT B669951G Spin Columns DM with Collection Tubes 50 sets RTProductsThis kit is suitable for extracting high purity total DNA from Gram-negative and Gram-positive bacteria. 106-108 cells can be processed at a time, and up to 20 µg of total DNA can be obtained within one hour without the need for toxic solvents such as phenol or chloroform, and without the need for ethanol precipitation. The optimized buffer system enables the DNA in the lysate to be efficiently and specifically bound to the silica matrix centrifugal adsorption column, while other contaminants can flow through the membrane, and the inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step, and finally washed off with low-salt buffer or water, so that high-purity DNA can be obtained.The purified DNA can be used for downstream experiments such as digestion, PCR, Real-Time PCR, library construction, Southern Blot and molecular labeling, molecular labeling and other downstream experiments. Self-contained reagents: anhydrous ethanol; Enzymatic Lysis Buffer is required for extraction of Gram-positive bacteria.Enzymatic Lysis Buffer was prepared by 20 mM Tris, pH 8.0; 2 mM Na2-EDTA, pH 8.0; and 1.2% Triton X-100. 121°C sterilization for 20 minutes, and the appropriate amount of Lysozyme was added at a final concentration of 20 mg/ml. Pre-experiment Preparation and Important Notes1. Add 1.25ml Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller DNA fragments and a decrease in the amount of extracted DNA.3. If extracting genomes from bacterial cultures with high accumulation of secondary metabolites or thick cell walls, it is recommended that samples be collected early in the logarithmic phase.4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.5. Before use, please check Buffer GTL and Buffer GL for crystallization or precipitation. If crystallization or precipitation occurs, please re-dissolve Buffer GL and Buffer GTL in a 56℃ water bath.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNase-Free RNase A (100mg/ml) can be added before adding Buffer GL. RNase A is not provided in this kit.If the extracted samples are Gram-positive bacteria, customers need to prepare their own Enzymatic Lysis Buffer to treat the bacteria, which requires the use of Lysozyme (lysozyme) at a concentration of 20 mg/ml, which is not provided in this kit.Procedurei Extraction of genomic DNA from Gram-negative bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180 µl Buffer GTL to the precipitate and shake to resuspend the bacteria.3. Add 20 µl of Proteinase K, vortex and mix well, incubate at 56°C until the solution becomes clear, and invert or shake the centrifuge tube at intervals during the incubation to disperse the sample.Note: If RNA removal is required, add 4 µl of RNase A solution at a concentration of 100 mg/ml after the above steps are completed, shake to mix, and leave for 5-10 minutes at room temperature.4. Add 200µl Buffer GL and mix well with vortexing and shaking. Add 200µl of anhydrous ethanol and mix well with vortexing and shaking.Centrifuge briefly so that the solution on the walls of the tube collects at the bottom.Note: 1) If multiple samples are manipulated together, Buffer GL and anhydrous ethanol can be mixed in equal proportions and then added together, shaking to mix.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add all of the solution obtained in step 4 (including the precipitate formed) to the Spin Columns DM in the collection tube, or if the solution cannot be added all at once, transfer it several times. centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.6. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and return the adsorption column to the collection tube.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorbent column at room temperature for several minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube, add 50-200 µl Buffer GE to the middle part of the adsorption column overhanging the center of the adsorption column, leave it at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20 ℃. note: 1) If the downstream experiments are sensitive to the pH or EDTA, the elution can be done with sterilized water. The pH of the elution solution has a great influence on the elution efficiency. If water is used as the elution solution it should be ensured that its pH is 7.0-8.5 (the pH of water can be adjusted to this range with NaOH), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 9 can be re-spiked onto the adsorbent membrane and step 9 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃.i. Extraction of genomic DNA from Gram-positive bacteria1. Take 1-5 ml of bacterial culture (106-108 cells, maximum 2×109 cells) and put it into a centrifuge tube (provided), centrifuge it at 12,000 rpm (~13,400×g) for 1 minute, and aspirate the supernatant as much as possible.2. Add 180µl Enzymatic Lysis Buffer (self-provided) to resuspend the bacteria.Enzymatic Lysis Buffer is prepared as described in the Self-Prepared Reagents section in the front of the manual.3. Incubate at 37°C for 30 minutes.4. Add 20µl Proteinase K and mix well. Add 200µl of Buffer GL and mix well with vortexing and shaking.Note: Do not add Proteinase K directly to Buffer GL.Incubate at 5.56°C for 30 minutes.Note: 1) If desired, incubation at 95°C for 15 minutes will inactivate the pathogen, but 95°C incubation will cause some DNA degradation.(2) If RNA removal is required, add 4µl of RNase A solution at a concentration of 100mg/ml after the above steps are completed, shake and mix well, and leave for 5-10 minutes at room temperature.6. Add 200µl of anhydrous ethanol and mix well with vortex shaking.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.7. Add all of the solution obtained in step 6 (including the precipitate formed) to the Spin Columns DM that have been loaded into the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid from the collection tube, and put the column back into the collection tube.8. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.9. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 9 can be repeated if further DNA purity is required.10. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self-provided), add 50-200 µl of Buffer GE to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 11 can be re-spiked onto the adsorbent membrane and step 11 repeated; if the elution volume is less than 200 µl, the final concentration of DNA can be increased, but the total yield may be reduced. If the amount of DNA is less than 1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.(5) DNA stored in water will be affected by acidic hydrolysis. For long-term storage, it is recommended to elute with Buffer GE and store at -20℃... Read More | Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize matrix effects, cross-reactions and unspecific binding in immunoassays like ELISA, Western blotting, Immunohistochemistry, protein arrays and immuno-PCR.The Effect Diluents, Animal-free are used alternatively to the standard sample or antibody dilution buffers: In ELISA for the dilution of specimen and detection antibodies. In Western Blotting for the dilution of primary and secondary antibodies. In Protein arrays for the dilution of specimen and detection antibodies. In immuno-PCR as a washing buffer.Three versions of the diluent are offered: Low, Medium and High for optimal discrimination between specific and unspecific reaction and for minimizing strong interference effects e.g., by RF (rheumatoid factors), HAMAs (human-a-mouse Abs) or by endogenous components that bind and mask the analyte.Composition & Properties The Effect Diluents, Animal free contain no animal components and are free of phosphates.Working Procedure 1.Mix thoroughly prior to use. 2.Dilution recommendations a.Dilute antibodies according to the instruction of the antibody b.Dilution of the specimen is recommended at 1:2 or higherTips & TricksEffect Diluents must not be considered as blocking buffers. Recommended blocking buffers are: Synthetic Blocking Buffer, ELISA (cat. no. S494401), Synthetic Blocking Buffer, Blotting (cat. no. S494457) and WellChampion (cat. no. W494467) for plate blocking and stabilization (preparation of pre-coated plates). Complex sample matrices, such as serum and plasma, may contain interfering factors that affect the ability of the assay to accurately quantify the target analyte. Strong interferences are often caused by RFs and HAMAs. This matrix effect can cause high background in the negative control or false negatives in the sample measurement. To reduce this effect the samples can be diluted in the Effect Diluents, Animalfree.Handling & Storage Store solution 2-8°C or -15 to -30°C (tolerates freezing and thawing cycles)... Read More | Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (Product content: Component O66550510 preps O665505 50 preps Blocking Buffer 100 ml 500 ml Antibody Pretreat Solution( HRP/Mouse ) 1 ml 5 × 1 ml Dilution Buffer 100 ml 500 ml Wash Buffer( 10× ) 100 ml 500 mlProduct Introduction:The one-step rapid WB assay kit (mouse) is the latest Western Blot detection kit developed by Kangwei Century, which can obtain high-quality Western Blot results in about 1 hour. It is easy to operate, has high detection sensitivity, low background, does not require the addition of secondary antibodies, and has strong system stability. The conventional Western Blot indirect detection process (blocking, primary antibody binding, and secondary antibody binding) requires a long time, a complex experimental process, and requires multi-step condition optimization. After transferring the protein on the gel to the carrier membrane, incubate it with the blocking solution in the reagent kit for 5 minutes, and then incubate the carrier membrane with the primary antibody treated with antibody reaction solution. After washing three times (5 minutes each time), luminescence or colorimetric detection can be performed. This reagent kit is designed for use in experimental systems where the target protein primary antibody is derived from mice.Notes:1. The customer prepares their own mouse source primary antibody.2. Before using Blocking Buffer blocking solution, Antibody Pretreat Solution (HRP/Mouse) antibody reaction solution (mouse), and Wash Buffer (10 x) rinse solution, please mix thoroughly.3. If there is precipitation in the rinsing solution when stored at 2-8 ℃, please restore it to room temperature, dissolve the precipitation, and use it normally. The 1x rinsing solution can be stored at room temperature for one month.4. It is recommended to stain the membrane with reagents such as spring red after the transfer is completed, and cut off any excess parts on the membrane to increase the efficiency of the reagents.5. The optimal dilution amount for primary antibody and antibody reaction solution HRP (mouse) needs to be determined through preliminary experiments.6. The antibody reaction solution HRP (mouse), antibody dilution solution, and antibody dosage can be increased or decreased proportionally according to the size of the membrane.7. The antibody dilution solution containing the first antibody can be recycled and reused once. It is recommended not to reuse antibodies with poor specificity and affinity. If the recovered antibody is used within 1-2 days and stored at 2-8 ℃ for long-term storage, please freeze it at -20 ℃ to avoid repeated freeze-thaw cycles.8. If there is a high background, please adjust the amount of antibodies and increase the number of times the film is washed.9. All reagents in the reagent kit should be stored at 2-8 ℃ to avoid freezing and thawing.Operation steps:This product is suitable for the sealing and antibody incubation steps after membrane transfer, taking a 5 cm x 8 cm membrane as an example:1. Preparation of rinsing solution: Dilute 10 ml of Wash Buffer (10 x) with distilled water to 100 ml, which is 1 x Wash Buffer. Set aside. Use 8-10 ml for each film wash.2. Sealing: After the membrane transfer is completed, immerse the membrane in 10 ml Blocking Buffer and seal at room temperature for 5 minutes.3. Rinse: Pour off the sealing solution, add 8-10 ml of 1 x Wash Buffer, and rinse at a high speed on a shaker for 1 minute.4. Prepare antibody incubation solution while washing the membrane: Take Antibody Pretreat Solution (HRP/Mouse) 100 µ Add mouse derived primary antibody 3-10 into the centrifuge tube µ g. Suck and beat the gun head until thoroughly mixed, and incubate at room temperature for 5 minutes. Add to 10 ml Dilution Buffer and mix well. Note: 1) The dosage of primary antibody can also be adjusted according to the dilution of the antibody. Taking the final dilution of antibodies at 1:1000 as an example, take 100 µ Add HRP (mouse) antibody reaction solution into the EP tube and add 10 µ Add the first antibody to 10 ml of antibody diluent, mix well, and incubate at room temperature for 5 minutes. 2) If the membrane area is small, the amount of antibodies, reaction solution, and diluent can be reduced proportionally.5. After completing step 3, pour out the rinsing solution and add the antibody incubation solution mixed with primary antibody, Antibody Pretreat Solution (HRP/Mouse), and Dilution Buffer to the membrane (ensuring that the incubation solution completely submerges the surface of the membrane). Incubate at room temperature on a shaker at around 60 rpm for 40 minutes.6. Discard (recover) the antibody incubation solution and rinse 3-5 times with the prepared 1 x Wash Buffer, each time for 3 minutes. 7. Conduct subsequent testing. It is recommended to use ECL or DAB methods for testing.Application examples:Example 1 Antigen is 293T cell lysateA: Normal WB control: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).B: One step method WB: beta actin mouse monoclonal antibody (CW0096) 5 µ Incubate at room temperature for 40 minutes and expose ECL (CW0049).Example 2 Antigen is E. coli multi label protein lysateC: Normal WB control: GST mouse monoclonal antibody (CW0084) 2.5 µ Incubate at room temperature for 40 minutes, wash the film and dilute the secondary antibody sheep anti mouse HRP (CW0102) 1:10000. Incubate at room temperature for 40 minutes and expose ECL (CW0049).D: One step method WB: GST mouse monoclonal antibody (CW0084) was incubated at room temperature with 2.5ug for 40 minutes, and ECL (CW0049) was exposed... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More |