| Description | Inquire | Product content:M665754Component25 TStorageM665754ATris-HCl, 1 mM, PH 8.01 mL-20℃. Avoid freeze/thaw cycleM665754BE. coli Poly(A) Polymerase, 5 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754C10×Poly(A) Polymerase Buffer80 µL-20℃. Avoid freeze/thaw Product content:M665754Component25 TStorageM665754ATris-HCl, 1 mM, PH 8.01 mL-20℃. Avoid freeze/thaw cycleM665754BE. coli Poly(A) Polymerase, 5 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754C10×Poly(A) Polymerase Buffer80 µL-20℃. Avoid freeze/thaw cycleM665754DATP, 10 mM15 µL-20℃. Avoid freeze/thaw cycleM665754ERT Primer, 25 µM90 µL-20℃. Avoid freeze/thaw cycleM665754F5×SuperRT Buffer120 µL-20℃. Avoid freeze/thaw cycleM665754GUltraPure dNTP Mix, 10 mM each30 µL-20℃. Avoid freeze/thaw cycleM665754HSuperRT, 200 U/µL15 µL-20℃. Avoid freeze/thaw cycleM665754IRNase-Free Water1 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kit uses the method of adding a poly (A) tail at the 3 'end of miRNA to give miRNA a Poly (A) tail, followed by reverse transcription using Oligo (dT) - Universal tag universal reverse transcription primers to synthesize the first stranded cDNA corresponding to miRNA. The miRNA cDNA first strand synthesis kit contains all the reagents required for the miRNA 3 'end Poly (A) tail modification process and the reverse transcription process after modification. This kit has a very high Poly (A) modification and reverse transcription efficiency, which can range from 1 ng-2 µ The first strand of cDNA corresponding to miRNA was effectively obtained from the total RNA of g. And the operation is simple and fast, which can be used to simultaneously detect multiple miRNAs from a synthesized cDNA reaction. This not only reduces errors and saves samples, but also achieves high-throughput detection.Note: This kit must be used in conjunction with the miRNA fluorescence quantitative detection kit.Self prepared experimental materials: 1 ng-2 µ Total RNA of g, or 0.1 ng-1 µ Small molecule RNA of g.Notes:To prevent RNase pollution, attention should be paid to the following aspects:1. Use plastic products and gun heads without RNase to avoid cross contamination.2. Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use. Plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3. The solution should be prepared using water without RNase.4. Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.Usage:A. The process of miRNA adding Poly (A) tail:1.based on the amount of RNA used, dilute the total RNA of 10 mM ATP with 1 mM Tris (pH 8.0) according to the following formula: ATP dilution coefficient=5000/__ ngExample: If the initial amount of total RNA is 100 ng, then the ATP dilution coefficient is 5000/100=50. About to dilute ATP 50 times (1 µ 10 mM ATP plus 49 for l µ 1 mM Tris at pH 8.0.2. Add the following reagents to the pre cooled RNase free reaction tube in the ice bath to a total volume of 25 µ L. reagent 25 µlReaction system final concentration total RNA* X µl Up to 2 µg 10×Poly(A) Polymerase Buffer 2.5 µl 1× Diluted ATP in step "1" 1 µl / E. coli Poly(A) Polymerase, 5U/µl 0.5 µl 2.5 U RNase-Free Water up to 25 µl /*The total RNA used in the reaction must contain small molecule RNA.This process can also directly use small molecule RNA (recommended dosage of 2-5) µ L. Please determine the amount added based on the abundance of the target miRNA.3. Gently mix the above reaction solution and briefly centrifuge to collect the liquid at the bottom of the tube. Incubate at 37 ℃ for 15 minutes. After this process is completed, immediately proceed with the synthesis of the first strand cDNA or temporarily store it at -20 ℃. If long-term storage is required, it is recommended to store at -80 ℃.B. The process of synthesizing the first strand of modified miRNA cDNA:1. Add the reagents in the table below to the pre cooled RNase free reaction tube in the ice bath until the final volume reaches 20µl: reagent 20 µlReaction system The above Poly (A) reaction solution 4 µl UltraPure dNTP Mix ,10 mM each 1 µl RT Primer ,25 µM 3 µl 5×SuperRT Buffer 4 µl SuperRT ,200 U/µl 0.5 µl RNase-Free Water 7.5 µl2. Gently mix the above reaction solution and briefly centrifuge to collect the liquid at the bottom of the tube. Incubate at 42 ℃ for 50 minutes.3.85 ℃ for 5 minutes and terminate the reaction. The synthesized cDNA reaction solution can be directly used for fluorescence quantitative detection experiments or stored at -20 ℃ for future use... Read More | DescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionGreen LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)527 nm wavelength0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More |