| Description | Inquire | Product IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized stateProduct IntroductionAlamar Blue detection reagent provides a simple, rapid, reliable and safe method for cell proliferation and cytotoxicity detection, which is suitable for high-throughput detection experiments. The main component of the detection reagent is a redox indicator. In the oxidized state, it appears purple-blue and non-fluorescent, while in the reduced state, it turns into a reduction product with pink or red fluorescence, with an absorption peak of 530-560nm and an emission peak of 590nm.In the process of cell proliferation, the ratios of NADPH/NADP, FADH/FAD, FMNH/FMN and NADH/NAD in the cell increase and are in a reducing environment. The dye taken into the cell is reduced by these metabolic intermediates and cytochromes and then released outside the cell and dissolved in the culture medium, changing the culture medium from non-fluorescent indigo blue to fluorescent pink. Finally, use an ordinary spectrophotometer or fluorophotometer for detection, and the absorbance and fluorescence intensity are proportional to the number of active cells.Instructions1. Add 10µl of detection reagent to 100µl of cell suspension, and incubate in a cell incubator for 2-6 hours. The color of the medium changes from indigo blue to pink and you can proceed to the next step.2. It is recommended to use a fluorescence microplate reader for detection, the excitation light wavelength is between 530-560 nm, the emission light wavelength is 590 nm, and the relative fluorescence unit (RFU) is recorded.3. Draw a standard curve or cell growth curve: the ordinate (Y axis) is the relative fluorescence unit (RFU); the abscissa (X axis) is the cell number or time point or drug concentration.Precautions1. The appropriate density of cells can increase the detection sensitivity. For 96-well plates, we recommend seeding 100 microliters of cells per well. The cell concentration range is: 100-10,000/well for adherent cells, 2,000-50,000/well for suspension cells, and medium as a blank control. For 384-well plates, the cell concentration and seeding volume are both halved.2. The whole process should be aseptic operation, because microbial contaminants can also reduce the detection reagents and affect the experimental results.3. Pay attention to the concentration of inoculated cells and the incubation time after adding detection reagents. If the cell concentration is too high or the incubation time is too long, it will cause a secondary reduction reaction, resulting in colorlessness and disappearance of fluorescence.4. When incubating, avoid light.5. This product can use fluorescence or spectrophotometric detection, but the sensitivity of fluorescence is high, and the experimental error is small. Fluorescence detection is recommended... Read More | Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Products content Box 1: Circularization reagentC666001Component16 TStorageC666001ASplint Oligo20 µL-20℃.Avoid freeze/thaw cycle. C666001B5×Splint Buffer T4250 µL-20℃.Avoid freeze/thaw cycle. C666001CDNA Ligase50 µL-20℃.Avoid freeze/thaw cycle. C666001DDigestion Buffer20 µL-20℃.Avoid freeze/thaw cycle. C666001EDigestion Enzyme I70 µL-20℃.Avoid freeze/thaw cycle. C666001FDigestion Enzyme III25 µL-20℃.Avoid freeze/thaw cycle. Box 2: Magnetic Beads for DNA Purification and RecoveryC666001Component16 TStorageC666001GCMPure4×1.5 mL2-8℃Products IntroductionThe Cyclization Kit is a modular kit tailored for the MGI high-throughput sequencing platform. With this kit, PCR products after junction ligation can be prepared into single-stranded circular DNA libraries suitable for MGI sequencers. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 (Cat. No. 12321D) is recommended.2. "Qubit" 3.0 Fluorescence Quantimeter (ThermoFisher, Cat. No. Q33216)3. Qubit" ssDNA Assay Kit (Invitrogen, Cat. No. Q10212)4. Anhydrous ethanol, EB (10 mM Tris-HCl, pH 8.0), NF Water (pH between 7.0 and 8.0).5. reaction tubes: low adsorption PCR tubes with 1.5 mIEP tubes are recommended: 5.Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and libraries. Pre-experiment Preparation and Important Notes 1. Sample preparation.PCR product: 2330 ng total (total amount when multiple PCR products are mixed) in a volume of 49 pL (if the volume of PCR product is insufficient, add NF Water to bring the total volume to 49 pl). -PCR product: Fragment size: The fragment peak is between 200-500 bp. -PCR product fragment size: Fragment peaks between 200-500 bp. -PCR product modification: Fixed sequences (with Index) for MGISEQ-2000, MGISEQ-200 and BGISEQ-500 sequencing platforms were added.2. Reagent preparation-Remove the corresponding reagents from the kit, centrifuge briefly, and place the enzyme mixture on ice until ready to use: buffers need to be dissolved at room temperature before use, then centrifuged with shaking and placed on ice until ready to use, and NF Water and EB are placed at room temperature until ready to use: "Please make up the mixture on ice:Precipitation may appear after the buffer in the kit is dissolved, the precipitation does not affect the function of the reagent, please shake and mix well until the precipitation disappears and then use. Schematic diagram of the cyclization process procedurecyclize 1. 1 wl of Splint Oligo was added to the 49JI PCR product. The product was denatured and incubated on a PCR instrument at 95°C for 3 min, then immediately transferred to an ice bath and allowed to stand for 2 min. 2. The reaction mixture was prepared on ice according to the following system. 3. Add 15ul of the above reaction mixture to 50µl of denatured DNA.4. Place the above PCR tubes on the PCR instrument under the following conditions Reaction. digest 1. Prepare the digestion reaction solution on ice according to the following system. 2. After the cyclization reaction, add 8l of digestion reaction solution directly to the cyclization system, mix well, centrifuge briefly and then place the PCR tube on the PCR instrument and react under the following conditions. 3. Purification was carried out immediately after the reaction.Purification of digestive products1. Remove CMPure at room temperature 30 minutes prior to use and mix well with shaking.2. Transfer the digested product to a 1.5 mIEP tube, pipette 340 pICMPure into the digested product, mix well by gently blowing 10 times with a pipette and incubate for 10 minutes at room temperature.3. Instantaneous centrifugation, place the EP tube on a magnetic rack and let stand for 5 minutes until the liquid is clear, pipette and discard the supernatant.4. Keep the EP tube fixed on a magnetic rack, add 250ul of freshly prepared 80% ethanol, let it stand at room temperature for 1 minute, then carefully discard the supernatant.5. Repeat step 4 once, try to suck up the liquid at the bottom of the tube: Note: Do not suck up the magnetic beads, so as not to affect the yield.6. Keep the EP tube fixed on the magnetic rack, open the cap and dry it at room temperature for 5-10 minutes.7. Remove the EP tube from the magnetic rack, add 35ul of EB or NF Water for DNA elution, pipette blow to mix and dissolve at room temperature for 10 min.8. Centrifuge instantaneously, place the EP tube on a magnetic rack and let stand for 2 minutes until the liquid is clarified, transfer the supernatant to a new EP tube. -Store at 20C and leave to prepare DNB... Read More | Products contentN669983Component240 TStorageN669983AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/thaw cycle.N669983BIndex N973-N996 Primers for Illumina24×10 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit to the transposase-Products contentN669983Component240 TStorageN669983AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/thaw cycle.N669983BIndex N973-N996 Primers for Illumina24×10 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a DescriptionThe Universal Coupling Kit makes particle-based immunoassays, lateral flow tests and biomolecule separation applications more flexible than ever before. It is the only kit that allows users to select and couple their choice of carboxylated particle with their chosen protein.Employing a unique mechanism to immobilise proteins, Anteo′s advantages outweigh those of conventional covalent chemistries such as NHS/EDC or passive binding. This facilitates coupling of antibodies with ease, improved functionality and reproducibility, leading to better uniformity between experiments.Anteo′s Activation Reagent is water-based and replaces the dry chemicals you would use with the traditional NHS/EDC method. Our One-Step-Activation only takes one hour, and improves efficiency in terms of both time and cost. It also provides the ability to either store activated particles up to 12 months for later use, or to immediately couple proteins.Particle-Based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More |