| Description | Inquire | Product Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 andProduct Descriptionalpha-L-fucoside fucohydrolase, alpha-L-fucosidase, alpha-(1-3,4) fucosidaseAlpha (1-3,4) Fucosidase The enzyme is very efficient and recognises α1-3,4 fucosylated glycans (e.g. Lewis X/A epitopes, including their sialylated counterparts) and hydrolyses terminal α1-3 and α1-4 fucosyl linkages in these substrates without the need to remove sialic acid moieties.For removing core fucose linked α-(1-6) to the core GlcNAc of a GlcNAc-GlcNAc disaccharide structure we recommend our Alpha-(1-6) Fucosidase.• Non-sialidase dependant hydrolysis of antennary fucose moieties• Effective on both glycopeptides and free glycans• Highly specific (α1-3,4 fucosylated glycans)• Kit includes enzyme plus reaction buffer.• Sufficient for up to 50 samplesα(1-3,4) Fucosidase is useful for:nbsp;nbsp;Fucose linkage determinationnbsp;nbsp;Deglycosylating glycoproteins with Lewis structuresContentsAlpha-(1-3,4)-Fucosidase – 200 mM citrate buffer pH 6 containing 250 mM NaCl5x Reaction Buffer – 250 mM sodium phosphate pH 6... Read More | DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking DescriptionThe 1 µm Coupling Kit makes conducting immunoprecipitation and biomolecule separation easier and more flexible. The Kit contains AnteoBind™activated 1 µm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise. Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 1 µm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to develop multifunctional particles for diverse applications, including dual labelling.Binding Capacity and Dispersity:Binding Capacity:> 20 µg IgG/mgMonodispersity:> 90% (by light microscopy determination)Particle based immunoassays, bioseparations and immunoprecipitation... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More |