| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product introduction:This kit uses uniqcell lysis and heme / protein precipitation technology, combined with DNA preparation membrane to selectively adsorb DNA to achieve the purpose of purifying genomic DNA.Scope of application:Nucleic acid extraction and purification | Product introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. FirstProduct introduction:Dualucif The firefly & Renilla assay kit (dual luciferase reporter assay kit) provides an effective means to detect the expression of genes. In DLR detection, the activities of firefly luciferase and Renilla luciferase can be detected in a single sample in turn. First, luciferin was used as substrate to detect the activity of firefly luciferase, then substances inhibiting the catalysis of firefly luciferase were added, and coelenterazine was added to detect the activity of Renilla luciferase to achieve dual luciferase reporter gene detection. The bioluminescence system of luciferase and its substrate can detect gene expression very sensitively and efficiently. Usually, the transcriptional regulatory element or 5'promoter region of the gene of interest is cloned upstream of luciferase, or the 3'-utr region is cloned downstream of luciferase to construct a reporter gene plasmid, and then transfect the cells. After the cells are treated with appropriate drugs, the cells are lysed, and the transcriptional regulation effect of drug treatment on the target gene is judged by detecting the luciferase activity. Renilla luciferase is more often used as an internal reference for detecting transfection efficiency to eliminate the difference in cell number and transfection efficiency. Firefly luciferase is a protein with a molecular weight of about 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. Renilla luciferase is a protein with a molecular weight of about 36 kDa. In the presence of oxygen, it can catalyze the oxidation of coelenteramide to coelenteramide, and also produce light signals in the process of coelenteramide oxidation. The optical signal of this kit can be measured by chemiluminescence instrument, microplate reader or liquid scintillation tester. The kit has the characteristics of rapid detection, high sensitivity, wide detection range and no interference of cell endogenous activity.Instruction:1.Cell lysis ( 1 ) Remove the medium and gently wash twice with PBS ( adherent cells can be operated directly, suspension cells need to be centrifuged to collect cells ). Add 1 × Lysis Buffer ( diluted component A with sterile water at 4 : 1 ) according to the following scheme, and then place the culture plate on a micro-oscillator at room temperature for 15 min to fully lyse the cells. Note : The pyrolysis products can be stored at room temperature for 6 h, and can be stored at − 70 °C for a long time ( the pyrolysis products cannot be repeatedly frozen and thawed ). ( 2 ) The pyrolysis products were centrifuged at 10000-15000 rpm for 3-5 min. After centrifugation, the supernatant was transferred into a new EP tube for subsequent detection. Note : Cells can be detected immediately after lysis, or frozen, and re-detected when needed. The frozen samples need to be thawed to room temperature for detection. 2. Preparation of working fluid ( 1 ) Restore all components to room temperature. ( 2 ) Dilute component C with component B to 0.2 mg / mL firefly luciferase working solution. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the amount of a single experiment is small, it is recommended to be subpackaged into small specifications according to a single amount of use. ( 3 ) The E component was diluted into the renilla luciferase working solution with the D component, and the dilution method was 1 µL E component was added to the 49 µL D component. Note : Renilla luciferase working solution needs to be prepared now. 3.chemiluminescence value detection ( 1 ) According to the operation instructions of the instrument, the instrument with chemiluminescence detection function was opened, such as multifunctional microplate reader. The parameters were set, the determination time was 10 s, and the determination interval was 2 s. ( 2 ) each sample determination, take the sample 20-100 µL ( if the sample volume is enough, please add 100 µL ; if the sample amount is insufficient, the amount can be appropriately reduced, but the amount of detection holes needs to be consistent ). 1 × Lysis Buffer was blank control. ( 3 ) 100 µL firefly luciferase working solution was added to determine the RLU ( relative light unit ) value ( it is recommended that the microplate reader set up the Shaking mixing function ). Note : Since the luminescence is instantaneous, it is recommended to detect immediately after adding the firefly luciferase working solution. ( 4 ) 100 µL renilla luciferase working solution was added to determine the RLU ( relative light unit ) value ( Shaking mixing function is recommended for microplate reader ). ( 5 ) In the case of renilla luciferase as an internal reference, the RLU value measured by firefly luciferase was divided by the RLU value measured by renilla luciferase. According to the obtained ratio, the activation degree of the target reporter gene between different samples was compared. If firefly luciferase is used as an internal reference, similar calculations can also be performed.Component:Recommendation:It is recommended to use component B in advance to prepare 2 mg / mL storage solution, component B, component D and component C prepared as storage solution, and to carry out small batch packing according to the experimental requirements. All test working fluids are recommended to be used now to avoid repeated freezing and thawing.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. in order to obtain the best determination effect, when using a single tube chemiluminescence instrument for determination, the time from the mixing of sample and determination reagent to the pre determination should be controlled as much as possible; When using a multi-functional fluorescent microplate reader with chemiluminescence detection function, it is advisable to add all samples first, and then uniformly add firefly luciferase detection reagent. 3. the strongest wavelength of firefly luciferase catalyzed bioluminescence is 560 nm, and the strongest wavelength of Renilla luciferase catalyzed bioluminescence is 480 nm. 4. to prevent interference between holes, it is recommended to use white opaque orifice plate. 5. due to the influence of temperature on enzyme reaction, the sample and reagent should be measured after reaching room temperature. 6. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Study on gene expression regulation and promoter... Read More | The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat The fluorescent dye PKH67 is suitable for conventional cell membrane labeling. It is a green fluorescent dye that can track cells in vitro and in vivo. It labels cells by binding to the lipid components of the membrane structure. PKH67 has low cytotoxicity, low fluorescence background, high fat solubility, can easily penetrate cell membranes, and has strong and stable green fluorescence. PKH67-labeled cells can be used for in vitro and in vivo proliferation studies, and have the function of not staining neighboring cells. In the process of cell division and proliferation, the fluorescence intensity of PKH67 will gradually decrease as the cells divide. The labeled fluorescence can be evenly distributed to the two sub-generation cells, so its fluorescence intensity is half that of the parent cell. According to this feature, It can be used to detect cell proliferation, cell cycle estimation and cell division, etc. The fluorescence of PKH67-labeled cells is very uniform, and the fluorescence distribution of sub-generation cells after division is also more uniform. In the process of cell division and proliferation, PKH67-labeled fluorescence can be evenly distributed between the two sub-generation cells, and the fluorescence intensity becomes half of that of the parent cell. According to the difference in fluorescence intensity, the undivided cells can be detected by flow cytometry. One time (1/2 the fluorescence intensity), the second time (1/4 the fluorescence intensity), three times (1/8 the fluorescence intensity), and more divisions of cells. PKH67 can detect splits up to six times or even more. In addition to the detection of cell proliferation, PKH67 can also be used for in vitro tracking of cells. After labeling, the fluorescence expression is stable in the cell, and the positive labeling rate is over 98%. The labeled cells have good morphology, which can effectively observe the cells in vitro. Induce differentiation; or inject labeled cells into the body, it can effectively show the migration and differentiation of transplanted cells in living tissues. PKH67-labeled cells can be used for in vivo observation for as long as several weeks. It is often used for in vivo cell detection experiments and experiments to observe long-term cell activity using fluorescence electron microscope. PKH67 is less toxic and does not affect cell proliferation. This method is simple to operate, does not use radioactive isotopes, and poses no safety hazards. You can get the desired experimental data faster, more accurately and more safely.Due to the longer length of the charcoal tail, internal studies have shown that PKH67 is less transferred between cells than PKH2. In in vivo studies using PKH1 and PKH2, the fluorescence intensity will slowly lose. Since this is a behavioral characteristic of green cell linker dye rather than red cell linker dye, PKH67 will have similar properties. The correlation between the in vitro cell membrane retention of non-dividing cells and the in vivo fluorescence half-life reveals that the in vivo fluorescence half-life of PKH67 is 10-12 days. Other green cell linker dyes with similar half-lives have been used to monitor the transport of lymphocytes and macrophages in the body within one to two months. The results indicate that PKH67 can also be used for medium-term in vivo tracking studies.The dye can stably bind to the lipid region of the cell membrane and emit fluorescence, and is mainly used for cell labeling in vitro, cell proliferation research in vitro, and cell tracing research in vivo and in vitro. The fluorescence half-life of PKH67 in vivo is 10-12 days. Compared with PKH-67, PKH-26 has a longer half-life, and the half-life of PKH26 labeled on rabbit red blood cells is more than 100 days. Especially suitable for in vitro proliferation research and long-term in vivo cell tracking research. After PKH67 labels the cells, flow cytometry is usually used for cell proliferation detection.Kit components0.1ml kits: P266290A-0.1ml P266290B-10ml1ml kits: P266290A-1ml P266290B-60mlDyes with A suffix and diluents with B suffix are used togetherPKH67 labeled cells show green fluorescence, the fluorescence wavelength: λex=490 nm, λem=502 nm.Storage conditions: -20℃ protected from light, valid for 1 yearPrecautions●Staining concentration varies according to the type of cell and the number of cells in each well.● The prepared PKH67 mother liquor is very easy to dissolve. It is recommended to store in aliquots and freeze-dry at ≦-20℃.● PKH67 working solution should be prepared for immediate use, and cannot be prepared in advance, because PKH67 will decompose due to the absorption of water and affect the dyeing effect.● PKH67 is easily decomposed and will deteriorate quickly in the water solution. Please avoid contact with water during use of mother liquor. The working fluid is in contact with the water during the process of labeling the cells within the permitted time range.● PKH67 fluorescent dye is a DMSO solution. It will solidify and stick to the bottom, wall or cap of the tube at a lower temperature such as 4℃ and ice bath. After being taken out of the refrigerator, it will return to room temperature and become After the liquid is in the state, remove the cap from the bottom of the tube. It can be used after it has completely melted in a 37°C water bath.● The number of generations or time that can be traced after different cell types are marked is quite different. Please make a test based on the actual situation or reference documents.Instructions1. Staining solution preparation:(1) Take out the PKH67 reagent from the refrigerator, let it stand for a few minutes to room temperature, or after a 37°C water bath, leave the tube containing PKH67, and be sure to leave the tube for a few minutes before opening the lid to allow the reagent to fully fall into the tube The lid can only be opened after the bottom.(2) According to the number of cell samples to be tested, dilute the probe 10 times with the diluent, and then use a suitable solution (such as non-clear medium, HBSS or PBS) to dilute the PKH67 mother liquor 25 times to prepare a stain Work fluid. The best working solution concentration should be adjusted according to different cells and your own experimental system. Generally, the cells can be diluted 250 times according to the final concentration of the mother liquor in the kit. Some cells may need to increase the concentration appropriately.2. Cell staining(1) Resuspend the prepared cells to be tested in 100µl of staining solution to a cell concentration of about 107/ml. You can also perform in-situ staining, as long as the staining solution is enough to cover the cells.(2) Culture the cells at 2~8℃ for 15~30 minutes. The best culture time is different for different cells.It is recommended to incubate the labeled cells in the staining solution at 37°C for 5 minutes, and then at 4°C for 15 minutes.Low-temperature incubation can reduce the endocytosis of the dye by the cells, help the dye to label the plasma membrane, and reduce the possibility of the dye localizing to cytoplasmic vesicles.(3) After separation, remove the supernatant, collect the cells, wash the cells 1-2 times with PBS or non-clear medium, and finally add PBS or non-clear medium to resuspend the cells.(4) Take 500µl of cell suspension and test with flow cytometer. Ex/Em=490/502nm.(5) Subsequently, the cells can be cultured according to the normal culture method.(6) The labeling effect can be directly observed under a fluorescence microscope, or the cell proliferation can be detected by a flow cytometer after an appropriate period of culture, or used for cell fluorescence traces for other specific experimental purposes... Read More | Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Product content: U665923Component50 T200 TStorageU665923ABuffer GTL15 mL60 mLRTU665923BBuffer GL15 mL50 mLRTU665923CBuffer GW1 (concentrate)13 mL52 mLRTU665923DBuffer GW2 (concentrate)15 mL70 mLRTU665923EBuffer GE15 mL60 mLRTU665923FProteinase K1.25 mL4×1.25 mLRTU665923GSpin Columns DM with Collection Tubes50 EA200 EART Product Introduction:This reagent kit is suitable for extracting high-purity total DNA from various samples such as fresh or frozen animal tissues, cells, blood, bacteria, etc. This product can purify DNA fragments with a maximum molecular weight of 50 kb. The purification process does not require the use of toxic solvents such as phenol or chloroform, nor does it require ethanol precipitation. This reagent kit adopts an optimized buffer system to efficiently and specifically bind DNA from the lysis solution to the silica matrix centrifuge adsorption column. Inhibitors of PCR and other enzymatic reactions can be effectively removed through a two-step washing step. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Self prepared reagent: anhydrous ethanolEnzymatic Lysis Buffer (preparation required for extracting genomic DNA from Gram positive bacteria).Self prepared reagent: Enzymatic Lysis Buffer Formula: 20 mM Tris, pH 8.0; 2 mM Na2 EDTA; 1.2% Triton self prepared reagent: X-100; Lysozyme with a final concentration of 20 mg/mL.Preparation and important precautions before the experiment:1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.If extracting the genome of bacterial cultures with a large accumulation of secondary metabolites or thick cell walls, it is recommended to collect samples early in the logarithmic growth phase.3.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer GTL and Buffer GL. If there is any crystallization or precipitation, please dissolve Buffer GL and Buffer GTL again in a 56 ℃ water bath.5. If downstream experiments are sensitive to RNA contamination, 4 can be added before adding Buffer GL µ RNase A of L DNase Free (100 mg/mL) was not provided in this kit.Operation steps:Genome extraction from blood and cell samples1. Material processing1a If the extracted material is mammalian anticoagulant blood (non nucleated red blood cells), it can be directly directed to 50-200 µ Add Buffer GTL to fresh or frozen anticoagulant blood samples to supplement up to 200 µ L;1b If the extracted material is anticoagulant blood from poultry, birds, amphibians, or lower level organisms, and their red blood cells are nucleated cells, take 5-10 µ L fresh or frozen anticoagulant blood samples, add Buffer GTL to supplement up to 200 µ L;1c The cells cultured on the wall should be first processed into a cell suspension (with a maximum extraction amount of 5 × 10 cells), centrifuged at 2000 rpm (400 × g) for 5 minutes, discarded from the supernatant, and added with 200 µ L GTL, oscillate until the sample is completely suspended;Note: To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL was vortexed for 15 seconds and left at room temperature for 2 minutes.2. Add 20 µ L Protein K.3. Add 200 µ L Buffer GL, vortex oscillation thoroughly mixed, 56 ℃ water bath for 10 minutes.4. Temporarily centrifuge to remove water droplets from the inner wall of the tube cover. Join 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well. Short centrifugation.Attention: 1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex shake and mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some organizations may form sol-gel products after adding Bu ff er GL and anhydrous ethanol, and it is recommended to perform severe shaking or vortex treatment at this time.5. Add all the solutions obtained in the previous step to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 7.8.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃.Genome extraction from animal tissues1. Material processingIf the extracted material is animal tissue, take 25 mg (the amount of spleen tissue should be less than 10 mg); If the material is mouse tail, take a section of rat tail with a length of 0.4-0.6 cm or two sections of mouse tail with a length of 0.4-0.6 cm.1a. After liquid nitrogen grinding or cutting the sample into small pieces, place it in a 1.5 mL centrifuge tube and add 180 mL µ Label different samples with L Buffer GTL.1b If using a homogenizer to process the sample, add no more than 80% of the homogenizer to the sample before homogenization µ L Buffer GTL, add 100 after homogenization µ L Buffer GTL.Attention:1) Ensure that the quantity of each organization does not exceed the recommended range.2) The tissue samples can be ground with liquid nitrogen or homogenized with a homogenizer before adding Bu ff er GTL, which can increase the cracking efficiency.2. Add 20 µ L Protein K, vortex oscillation thoroughly mixes the sample. Take a 56 ℃ water bath until the tissue is completely lysed. During the incubation process, the centrifuge tube can be inverted or shaken periodically to disperse the sample.Attention:1) The digestion time varies for different tissues, usually taking 1-3 hours to complete. The tail of the mouse needs to be digested for 6-8 hours, and if necessary, overnight digestion will not affect subsequent operations.2) If there is still gel like substance after incubation and vortex oscillation, extend the incubation time at 56 ℃ or add another 20 µ L Protein K digestion.3) To remove RNA, add 4 after completing the above steps µ RNase A solution with a concentration of 100 mg/mL, vortex for 15 seconds, and leave at room temperature for 5-10 minutes.3. Add 200 µ L Buffer GL, vortex shake thoroughly and mix well, take a water bath at 70 ℃ for 10 minutes. Add 200 after brief centrifugation µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention:1) After adding Bu ff er GL and anhydrous ethanol, immediately vortex and shake to mix well.2) The addition of Bu ff er GL and anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments. Some tissues (such as the spleen and lungs) may form sol-gel products after adding Bu ff er GL and anhydrous ethanol. In this case, it is recommended to perform vigorous shaking or vortex treatment.4. Centrifuge briefly and add all the solution obtained in step 3 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 6.7.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).8. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃. i ii Genomic extraction of blood and cell samples1. Bacterial sample pretreatment1a Gram negative bacteria(1) Take 1-5mL of bacterial culture (10 ^ -10 ^ cells, up to a maximum of 2 × 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm (~13400 × g) for 1 minute and try to aspirate the supernatant as much as possible.(2) Add 180 to the precipitate µ L Buffer GTL, shake to suspend bacterial weight.(3) Join 20 µ L Protein K, vortex mix well, incubate at 56 ° C until the bacterial cell is completely lysed, and during the incubation process, invert or shake the centrifuge tube periodically to disperse the sample.Note: To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.(4) Join 200 µ L Buffer GL, vortex oscillation mixing.1b Gram positive bacteria(1) Take 1-5 mL of bacterial culture (10 ^ -10 ^ cells, maximum not exceeding 2 x 10 ^ cells) and place it in a centrifuge tube (self prepared). Centrifuge at 12000 rpm for 1 minute and try to aspirate the supernatant as much as possible.(2) Join 180 µ L Enzymatic Lysis Buffer (self provided) suspends the bacterial weight.(3) Incubate at 37 ℃ for 30 minutes.(4) Join 20 µ L Protein K vortex oscillation, thoroughly mixed. Join 200 µ L Buffer GL, vortex oscillation mixing. Incubate at 56 ℃ for 30 minutes.Attention:1) If necessary, incubation at 95 ° C for 15 minutes can inactivate the pathogen, but incubation at 95 ° C can cause some DNA degradation.2) To remove RNA, add 4 after completing the above steps µ L RNase A solution with a concentration of 100 mg/mL, shake well and let stand at room temperature for 5-10 minutes.2. Add 200 µ L anhydrous ethanol, vortex and shake thoroughly to mix well.Attention: Adding anhydrous ethanol may produce white precipitates, which will not affect subsequent experiments.3. Add all the solution obtained from step 2 (including the formed precipitate) to the adsorption column (Spin Columns DM) that has been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.4. Add 500 to the adsorption column µ L Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Add 500 to the adsorption column µ L Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: To further improve DNA purity, repeat step 5.6.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).7. Place the adsorption column in a new centrifuge tube (provided by oneself) and add 50-200 to the middle of the adsorption column in the air µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Attention:1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency is not high.2) Preheating the GE in a water bath at 65-70 ℃ and incubating it at room temperature for 5 minutes before centrifugation can increase yield; Use an additional 50-200 µ Re washing with GE or sterilized water can increase yield.3) If the final concentration of DNA needs to be increased, the obtained solution can be re added to the adsorption column, left at room temperature for 2-5 minutes, and centrifuged at 12000 rpm for 1 minute; If the elution volume is less than 200 µ L. It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with GE or sterilized water.4) Because DNA stored in water is affected by acidic hydrolysis, if long-term preservation is required, it is recommended to elute with Bu ff er GE and store at -20 ℃... Read More |