| Description | Protein Labeling Kit (Aggregation-induced emission, AIE) is developed based on the principle of aggregation-induced emission (AIE) and is used for labeling general proteins. Its labeling principle is that the AIE dye in the kit carries active groups, which can react with the primary amino groups (Protein Labeling Kit (Aggregation-induced emission, AIE) is developed based on the principle of aggregation-induced emission (AIE) and is used for labeling general proteins. Its labeling principle is that the AIE dye in the kit carries active groups, which can react with the primary amino groups (lysine residues) on the protein surface to form stable amide bonds. The AIE dye has high reactivity and can quickly label general proteins. The optimal excitation wavelength of the AIE dye is 460 nm, and the emission wavelength range is 570–700 nm, which is suitable for a series of instruments equipped with a blue light excitation wavelength detector. Marking renderings:Notes:After receiving the product, customers should store it according to the temperature indicated on the product label.Customers need to prepare dimethyl sulfoxide (DMSO) reagents and disposable syringe consumables by themselves. Experimental Methods 1.Replacement of protein sample buffer solvent: Before starting to label the protein, ensure that the protein sample buffer is compatible with the kit. If your protein sample buffer contains one or more of primary amino groups (such as Tris and glycine), imidazole, DTT, and β-mercaptoethanol, please replace it with Buffer 1× buffer solution before labeling.2.Preparation of AIE dye stock solution: Add 20 µL of DMSO to the small tube containing AIE dye lyophilized powder, mix well to dissolve, and prepare a 10 mM AIE dye stock solution.Notes: 1) Before dissolving with DMSO, let the AIE dye lyophilized powder return to room temperature and centrifuge for 10 seconds. 2) After dissolution, it can be aliquoted for storage as needed.3.Protein labeling method (recommended) 1) Dilute the protein sample with Buffer 1× to a concentration of approximately 150 µg/mL. 2) Add 10 mM AIE dye stock solution to the above protein sample solution to make its final concentration in the protein sample solution 10 µM (for example, when the volume of the protein sample solution is 1 mL, add 1 µL of 10 mM AIE dye stock solution; the dosage can be adjusted according to the actual situation of the protein sample), and mix well. 3) Incubate at room temperature in the dark for 5–10 minutes. 4) After labeling, filter the labeled solution with a 0.1 µm needle filter to remove excess AIE dye.PrecautionsThe AIE dye is sensitive to humidity, so ensure that it is stored at -20°C in a dry and dark place. Before preparing the stock solution, let the dye return to room temperature and centrifuge for 10 seconds. After preparing the stock solution, aliquot it for storage and use it as soon as possible.The buffer solution (pH = 8.5) provided in the kit is the first choice for the AIE dye to work. You can choose any buffer solution that does not contain primary amino groups, imidazole, DTT, or β-mercaptoethanol as a substitute, but it may affect the labeling efficiency.It is recommended that the minimum concentration of the protein during labeling is not less than 15 µg/mL.Due to the differences in the number and reactivity of amino groups on the protein surface, the labeling effects of different proteins may vary. If the labeling effect is not good, the dye labeling concentration can be appropriately increased or the reaction time can be prolonged.For your safety and health, please wear a lab coat and disposable gloves during operation.This product is only for scientific research purposes... Read More | DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise.Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 200 nm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to produce multifunctional particles for diverse applications, including dual labelling.For lateral flow tests, magnetic particles are easier to handle than gold. Magnetic separation removes the need to perform centrifugation and filtration concentration. Magnetic particles can provide greater sensitivity than gold during lateral flow tests.Binding Capacity and Polydisperity IndexBinding Capacity: > 50 µg IgG/mgPolydispersity Index (PdI)*: < 0.3* The Polydispersity Index (PdI) is dimensionless and determined using Dynamic Light Scattering (DLS). The PdI is scaled such that values smaller than 0.05 are rarely seen and values greater than 0.7 indicate that the sample has a very broad size distribution and poor monodispersity.Particle based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | DescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatableDescriptionWhite LED Array for Photo KitAlysis high-throughput screening platform. For use with Photo KitAlysis Starter Kit (Z742612). User guide is provided in the below hyperlink.Photo KitAlysis Operating InstructionsFeatures:Designed and tested by synthetic chemists.Controller provides repeatable milliamp selection for photon intensity (sold seperately)0-30 mA variable LED outputNon-magnetic LED baseChemically resistant LED coverPTFE coated cablingPhoto Kitalysis Starter Kitrequired for operation (sold separately). Best when used withKitAlysis Benchtop Inertion Box(sold separately)... Read More | Inquire |