| Description | Inquire | Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products IntroductionThis product is mainly used for PCR using bisulfite-treated DNA as template, in which SuperFastStar DNA Polymerase is a new high-efficiency hot-start enzyme modified by bis-monoclonal antibody, which is completely blocked at room temperature, thus effectively avoiding non-specific amplification caused by the non-specific binding of the primer to the template or the primer dimerization under the condition of room temperature. The optimized FastStar Probe Buffer (for bisDNA) contains PCR Buffer, dNTPs and Mg2+, etc., which is easy to use as customers only need to add templates, primers and probes.caveat1 Before use, please mix the product gently by turning it up and down after it has been completely melted and centrifuged briefly.2. Avoid repeated freezing and thawing of the product, which may degrade its performance. This product can be stored at -20℃ for a long period of time, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.Usage The following examples are conventional PCR reaction systems and conditions, which should be improved and optimized according to the template, primer structure and target fragment size.1.PCR reaction system Note: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.2)The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3)Usually the amount of DNA template is 10-100 ng of genomic DNA or 1-10 ng of cDNA as a reference. Since the templates of different species contain different copy numbers of the target gene, the templates can be diluted in gradients to determine the optimal amount of template to use.2.PCR reaction conditionsNote: 1) The initial denaturation of this product at 95°C for 30s is sufficient for enzyme activation; complex templates can be extended to 3min denaturation.(2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More |