| Description | Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction solutions, or crude DNA (including genomic DNA) obtained by various methods. Buffer PB contains a pH indicator, and the solution is yellow, which facilitates judging whether the pH value of the solution is suitable for binding to the DNA adsorption column. The DNA recovery efficiency can be as high as 80%, and the purified DNA can be directly used for sequencing, ligation, restriction enzyme digestion (enzyme digestion), PCR, labeling, and other applications.Product Components and Storage Conditions: U1492721 ComponentComponentStorage U1492721ABuffer BL30 mlRT U1492721BBuffer PB25 mlRT U1492721CBuffer DW212 mlRT U1492721DBuffer EB10 mlRT U1492721EFineBind MinElute DNA Spin Columns50个RT U1492721F2 ml Collection Tubes50个RTStorage Conditions:This kit can be stored for 12 months at room temperature (15°C–25°C) under dry conditions. Precipitation may form in Buffer PB at low temperatures; before use, it is necessary to redissolve the buffer in a 37°C water bath and shake it well before use.Precautions:1. The addition of Buffer BL can improve the adsorption capacity of the adsorption column, enhance its uniformity and stability, and eliminate the impact of high temperature/humidity or other adverse environmental factors on the adsorption column. Before use, please check whether Buffer BL is turbid. If turbidity occurs, heat it in a 37°C water bath for a few minutes to restore clarity.2. Buffer PB contains a pH indicator and is yellow, indicating a pH ≤ 7.5.Operating Steps:Before use, add absolute ethanol to Buffer DW2. Please refer to the label on the bottle for the volume to be added.I. Recovering DNA Fragments from Agarose Gels1. Column Equilibration Step: Add 500 µl Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube. (Please use columns processed on the same day)2. Cut the single target DNA band from the agarose gel (remove excess parts as much as possible) and place it in a clean centrifuge tube, then weigh it.3. Add an equal volume of Buffer PB to the gel block (if the gel weighs 0.1 g, its volume can be regarded as 100 µl, so add 100 µl Buffer PB). Incubate in a 50°C water bath for about 10 minutes, gently inverting the centrifuge tube up and down continuously during this period to ensure the gel block is fully dissolved. (If the volume of the gel block is too large, it can be cut into small pieces in advance.)Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after the gel block is completely dissolved, it is best to cool the solution to room temperature before loading onto the column, because the adsorption column has a stronger ability to bind DNA at room temperature. The gel should appear yellow after complete dissolution, and then subsequent operations can be performed. If the color of the solution is orange-red or purple after the gel is completely dissolved, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before proceeding with subsequent operations. (Buffer PB contains a pH indicator. When pH ≤ 7.5, the solution is yellow, and DNA can effectively bind to the membrane. When the pH is high, the solution turns orange-red or purple and needs to be adjusted.)4. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume is larger than 700 µl, it can be added in batches.5. Add 500 µl Buffer DW2 (with absolute ethanol added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Repeat step 5.7. Centrifuge at 12,000 rpm for 3 minutes.8. Place the adsorption column into a clean centrifuge tube, 悬空滴加 an appropriate amount of Buffer EB (Buffer EB is heated at 65°C for 3-5 minutes before use, preheated in advance) to the middle part of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will affect the recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used for elution. The pH of the eluent has a great impact on the elution efficiency. If water is used as the eluent, ensure its pH is within 7.0-8.5 (NaOH can be used to adjust the pH of water to this range). The elution efficiency is low when the pH is below 7.0.II. Recovering DNA from PCR Reaction Solutions or Restriction Enzyme Digestion Solutions1. Column Equilibration Step: Add 500 µl of Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. (Please use columns processed on the same day.)2. Calculate the volume of the PCR reaction solution or restriction enzyme digestion solution, add an equal volume of Buffer PB to it, and mix thoroughly (there is no need to remove paraffin oil or mineral oil).Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after mixing, the solution should appear yellow before proceeding with subsequent operations. If the solution is orange-red or purple, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before continuing.3. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume exceeds 700 µl, add it in batches.4. Add 500 µl of Buffer DW2 (ensure absolute ethanol is added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Repeat step 4 once.6.Centrifuge at 12,000 rpm for 3 minutes.7. Transfer the adsorption column to a clean centrifuge tube, suspend and add an appropriate amount of Buffer EB (preheat Buffer EB by heating at 65°C for 3–5 minutes before use) to the middle of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will reduce recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used as the eluent. The pH of the eluent has a significant impact on elution efficiency. If water is used as the eluent, ensure its pH is within the range of 7.0–8.5 (NaOH can be used to adjust the pH of water to this range); elution efficiency will be low if the pH is below 7.0... Read More | The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:Ιnertion Box24-Well Reaction BlockTorque Screwdriver set with bitReaction Block Replacement Screws (10ea)... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire |