| Description | Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction solutions, or crude DNA (including genomic DNA) obtained by various methods. Buffer PB contains a pH indicator, and the solution is yellow, which facilitates judging whether the pH value of the solution is suitable for binding to the DNA adsorption column. The DNA recovery efficiency can be as high as 80%, and the purified DNA can be directly used for sequencing, ligation, restriction enzyme digestion (enzyme digestion), PCR, labeling, and other applications.Product Components and Storage Conditions: U1492721 ComponentComponentStorage U1492721ABuffer BL30 mlRT U1492721BBuffer PB25 mlRT U1492721CBuffer DW212 mlRT U1492721DBuffer EB10 mlRT U1492721EFineBind MinElute DNA Spin Columns50个RT U1492721F2 ml Collection Tubes50个RTStorage Conditions:This kit can be stored for 12 months at room temperature (15°C–25°C) under dry conditions. Precipitation may form in Buffer PB at low temperatures; before use, it is necessary to redissolve the buffer in a 37°C water bath and shake it well before use.Precautions:1. The addition of Buffer BL can improve the adsorption capacity of the adsorption column, enhance its uniformity and stability, and eliminate the impact of high temperature/humidity or other adverse environmental factors on the adsorption column. Before use, please check whether Buffer BL is turbid. If turbidity occurs, heat it in a 37°C water bath for a few minutes to restore clarity.2. Buffer PB contains a pH indicator and is yellow, indicating a pH ≤ 7.5.Operating Steps:Before use, add absolute ethanol to Buffer DW2. Please refer to the label on the bottle for the volume to be added.I. Recovering DNA Fragments from Agarose Gels1. Column Equilibration Step: Add 500 µl Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube. (Please use columns processed on the same day)2. Cut the single target DNA band from the agarose gel (remove excess parts as much as possible) and place it in a clean centrifuge tube, then weigh it.3. Add an equal volume of Buffer PB to the gel block (if the gel weighs 0.1 g, its volume can be regarded as 100 µl, so add 100 µl Buffer PB). Incubate in a 50°C water bath for about 10 minutes, gently inverting the centrifuge tube up and down continuously during this period to ensure the gel block is fully dissolved. (If the volume of the gel block is too large, it can be cut into small pieces in advance.)Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after the gel block is completely dissolved, it is best to cool the solution to room temperature before loading onto the column, because the adsorption column has a stronger ability to bind DNA at room temperature. The gel should appear yellow after complete dissolution, and then subsequent operations can be performed. If the color of the solution is orange-red or purple after the gel is completely dissolved, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before proceeding with subsequent operations. (Buffer PB contains a pH indicator. When pH ≤ 7.5, the solution is yellow, and DNA can effectively bind to the membrane. When the pH is high, the solution turns orange-red or purple and needs to be adjusted.)4. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume is larger than 700 µl, it can be added in batches.5. Add 500 µl Buffer DW2 (with absolute ethanol added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Repeat step 5.7. Centrifuge at 12,000 rpm for 3 minutes.8. Place the adsorption column into a clean centrifuge tube, 悬空滴加 an appropriate amount of Buffer EB (Buffer EB is heated at 65°C for 3-5 minutes before use, preheated in advance) to the middle part of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will affect the recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used for elution. The pH of the eluent has a great impact on the elution efficiency. If water is used as the eluent, ensure its pH is within 7.0-8.5 (NaOH can be used to adjust the pH of water to this range). The elution efficiency is low when the pH is below 7.0.II. Recovering DNA from PCR Reaction Solutions or Restriction Enzyme Digestion Solutions1. Column Equilibration Step: Add 500 µl of Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. (Please use columns processed on the same day.)2. Calculate the volume of the PCR reaction solution or restriction enzyme digestion solution, add an equal volume of Buffer PB to it, and mix thoroughly (there is no need to remove paraffin oil or mineral oil).Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after mixing, the solution should appear yellow before proceeding with subsequent operations. If the solution is orange-red or purple, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before continuing.3. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume exceeds 700 µl, add it in batches.4. Add 500 µl of Buffer DW2 (ensure absolute ethanol is added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Repeat step 4 once.6.Centrifuge at 12,000 rpm for 3 minutes.7. Transfer the adsorption column to a clean centrifuge tube, suspend and add an appropriate amount of Buffer EB (preheat Buffer EB by heating at 65°C for 3–5 minutes before use) to the middle of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will reduce recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used as the eluent. The pH of the eluent has a significant impact on elution efficiency. If water is used as the eluent, ensure its pH is within the range of 7.0–8.5 (NaOH can be used to adjust the pH of water to this range); elution efficiency will be low if the pH is below 7.0... Read More | DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily DescriptionUse in combination with the KitAlysis Bench Top Inertion Box (Z742064) or a glove box/glove bag to provide inert atmosphere for kit set-up.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:24-Well Reaction BlockTorque ScrewdriverSmall screwdriver to easily remove torqued screws after reaction is complete.10 Reaction Block Replacement Screws... Read More | Inquire | Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 Product content N665859Component50 TStorageN665859ABuffer DS30 mLRTN665859BBuffer GTL15 mLRTN665859CBuffer GL15 mLRTN665859DBuffer GW1 (concentrate)13 mLRTN665859EBuffer GW2 (concentrate)15 mLRTN665859FBuffer TE10 mLRTN665859GProteinase K2×1.25 mLRTN665859HRNase A (100 mg/mL)0.4 mLRTN665859ISpin Columns DF With Collection Tubes50 EA2-8℃N665859JCentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the effective purification of genomic DNA from formalin-fixed, paraffin-embedded tissues.The product uses specially optimized dewaxing agent and lysis solution to release DNA from formalin-fixed or tissue sectioned samples, which does not involve the organic reagent xylene and does not need to be operated overnight; the digested samples are incubated at higher temperatures to remove formalin cross-linking of the free DNA, which can effectively improve the yield and purity of DNA; the optimized buffer system allows the inhibitors in the lysis solution to be specifically bound to the adsorbent membrane, which can be effectively removed by a two-step rinsing step. The optimized buffer system enables the DNA in the lysate to specifically bind to the adsorbent membrane, and the inhibitor is effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high-purity DNA.Meanwhile, configured with a high-efficiency microsorbent column, the elution volume can be as low as 20 µL.The purified DNA can be directly used for PCR, Real-time PCR, SNP Genotyping, STR genotyping, second-generation sequencing and pharmacogenomics research.The molecular weight of DNA isolated from formalin-fixed, paraffin-embedded samples is usually lower than that of DNA from fresh or frozen samples.The degree of DNA fragmentation depends on the type of sample, the duration of storage, and the conditions of fixation.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. After obtaining the sample, fix the sample in 4%-10% formalin as soon as possible, the fixation time should be 14-24 hours, too long a period of time will easily lead to genome breakage, affecting the downstream experiments. If the formaldehyde fixation time is too long or the sample has been stored for too long (> 1 year), it will easily lead to DNA integrity damage and unable to amplify long fragments.2. Ensure that the sample is thoroughly dehydrated before embedding; residual formalin will inhibit Proteinase K.3. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.4. Before use, please check Buffer GTL, Buffer GL and Buffer DS for any crystallization or precipitation. If there is any crystallization or precipitation, please re-dissolve Buffer GTL, Buffer GL and Buffer DS at 56℃ in a water bath.5. Preheat the water bath or thermostatic mixer to 56°C and keep the centrifuge at 25°C before starting the experiment.6. If downstream experiments are needed to reduce the low frequency of C>T:G>A transitions (artificial mutations) that occur to minimize the risk of false positives, 7 µL of UNG (1 U/uL) can be added after 1 hour of incubation at 90°C.Operation steps1. Sample processing:1a. Paraffin-embedded samples: Trim off excess paraffin from the tissue block with a scalpel to expose the tissue and then cut into 5-10µm slices. Take about 1×1cm2 slices (about 4-5 slices in total) and place them in a centrifuge tube (provided), add 160µL Buffer DS, vortex and shake for 10 seconds, then add 180µL Buffer GTL and 20µL Proteinase K, vortex and shake for 10 seconds. centrifuge the samples at 12,000rpm for 1 minute at 25℃.Note: 1) If the surface of the sample has been exposed to air, discard the 2-3 pieces that have been exposed to air and do not use them.2) DS will solidify below 18°C, and if it does it does not affect the following experiments.1b. Sample in formalin and other fixative: take about 20mg of sample, cut it into small pieces, place it in a centrifuge tube, add 500µL of 10mM PBS (PH7.4), vortex shaking, centrifuge at 12,000rpm for 1minute, discard the supernatant, and repeat 3 times. Add 180 µL Buffer GTL, 20 µL Proteinase K, vortex shaking to mix.2.56°C for 1 hour until the sample is completely dissolved. incubate at 90°C for 1 hour. centrifuge at 12,000 rpm, 25°C for 1 minute, and carefully pipette the lower aqueous phase (~180 µL) along the wall of the tube into a new centrifuge tube, trying to avoid aspirating the bottom precipitate and the upper layer of the wax solution.Note: 1) Samples can be left at room temperature after incubation at 56°C until the temperature of the water or dry bath reaches 90°C before placing the samples at 90°CIncubation.2) Optional step: add 7µL UNG (1U/µL), 50°C, 5min, no shaking. The purpose of this step is to minimize the risk of false positives by reducing the low-frequency occurrence of C>T:G>A transitions (artificial mutations) while effectively retaining the true occurrence of mutations.3. Optional step: If you need to remove RNA, you can lower the temperature of the sample to room temperature, then add 2µL of RNase A solution at a concentration of 100mg/mL, shake and mix well, and leave it at room temperature for 2 minutes.4. Add 20µL Proteinase K and incubate at 65℃, 450rpm for 15min.5. Add 200 µL of Buffer GL, mix well by vortexing and shaking, then add 200 µL of anhydrous ethanol and mix thoroughly by vortexing and shaking. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: 1) Mix well immediately after adding Buffer GL and anhydrous ethanol.2) The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.3) If more than one sample needs to be manipulated, the Buffer GL and anhydrous ethanol can be pre-mixed and spiked.6. Add all the solution obtained in step 5 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tube, centrifuge at 25℃, 12000rpm for 2 minutes, pour out the waste liquid in the collection tube, and put the adsorption columns back into the collection tube.7. Add 500µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.8. Add 500µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12000rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 8 can be repeated if further DNA purity is required.9.12 Centrifuge at 2000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions.10. Place the adsorption column in a new 1.5 mL collection tube, add 20-100 µL of Buffer TE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, centrifuge it at 12,000 rpm for 1 minute, and collect the DNA solution.-20°C to preserve DNA.Note: 1) The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5, the pH value is lower than 7.0 when the elution efficiency is not high.2) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-spiked onto the adsorbent membrane and left at room temperature for 2 minutes and centrifuged at 12,000 rpm for 1 minute... Read More | Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable Product contentS665868Component50 TStorageS665868ABuffer GL25 mLRTS665868BBuffer GW1 (concentrate)13 mLRTS665868CBuffer GW2 (concentrate)15 mLRTS665868DBuffer GE15 mLRTS665868EProteinase K2×1.25 mLRTS665868FSpin Columns DM with Collection Tubes50 setsRTProduct IntroductionThis kit is suitable for the extraction of genomic DNA from fresh saliva or saliva/preservation solution mixture.The purification process of this product does not require the use of toxic solvents such as phenol or chloroform, and ethanol precipitation is not necessary. The optimized buffer system enables DNA to bind heterogeneously to the silica matrix centrifugal adsorption column, and the inhibitors of PCR and other enzymatic reactions can be effectively removed by a two-step washing step, and finally eluted with a low-salt buffer or water to obtain high-purity DNA.The purified obtained can be directly used for enzyme digestion, PCR, Real-Time PCR, library construction, Southern Blot, molecular labeling and other downstream experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.3. Before use, please check whether Buffer GL appears to be crystallized or precipitated.Redissolve in a 56°C water bath.4. If the downstream experiments are sensitive to RNA contamination, 4 µL DNase-Free RNase A can be added in step 3(100 mg/mL).5. For prolonged storage of salivary DNA at room temperature, our Salivary DNA Preservation Tubes are recommended.Operation steps1. Add 400 µL of saliva sample or saliva/preservation solution mixture.Note: 1) Saliva mixtures added to the preservation solution require a 50°C water bath for 1 hour or an empty 50°C temperature chamber for 2 hours prior to extraction.2) If an increase in sample volume is required, multiply the volumes of Proteinase K, Buffer GL, and anhydrous ethanol in Steps 2-4, and the liquid can be transferred in multiple times in Step 5.2. Add 40 µL of Proteinase K.3. Add 400µL Buffer GL, vortex and shake to mix thoroughly, and water bath at 56℃ for 15-30 minutes.Note: If RNA removal is required, add 4 µL of RNase A solution at a concentration of 100 mg/mL after the above steps are completed, vortex for 15 seconds, and leave at room temperature for 2 minutes.4. Centrifuge briefly to remove water droplets from the inside of the tube cap. Add 400 µL of anhydrous ethanol and mix well by vortexing and shaking. Centrifuge briefly.Note: 1) Vortex and shake to mix immediately after adding Buffer GL and anhydrous ethanol.The addition of Buffer GL and anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.2) A sol-gel product may be formed after GL and anhydrous ethanol, in which case vigorous shaking or vortexing is recommended.3) The solution obtained in the previous step is added to the adsorption column in the Collection Tube.5. (Spin Column DM) in the collection tube, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge at 12,000 rpm (∼13,400 × g) for 1 min, pour off the waste solution in the collection tube, and put the adsorption column back into the collection tube.6. Add 500 µL of Buffer GW1 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new centrifuge tube (supplied), add 50-200 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let it stand at room temperature for 2-5 minutes, and centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.-20°C to preserve DNA.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH is 7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elution efficiency is not high when the pH is lower than 7.0.2) Buffer GE preheated in a 65-70°C water bath and incubated at room temperature for 5 min before centrifugation can increase the yield.3) Because DNA preserved in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C is recommended... Read More |