| Description | Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction Product Introduction:This kit is based on spin column adsorption technology and is suitable for recovering 50 bp–30 Kb DNA fragments from agarose gels of various concentrations. In addition, the kit is also suitable for recovering and purifying DNA from PCR products, enzymatic reaction solutions, or crude DNA (including genomic DNA) obtained by various methods. Buffer PB contains a pH indicator, and the solution is yellow, which facilitates judging whether the pH value of the solution is suitable for binding to the DNA adsorption column. The DNA recovery efficiency can be as high as 80%, and the purified DNA can be directly used for sequencing, ligation, restriction enzyme digestion (enzyme digestion), PCR, labeling, and other applications.Product Components and Storage Conditions: U1492721 ComponentComponentStorage U1492721ABuffer BL30 mlRT U1492721BBuffer PB25 mlRT U1492721CBuffer DW212 mlRT U1492721DBuffer EB10 mlRT U1492721EFineBind MinElute DNA Spin Columns50个RT U1492721F2 ml Collection Tubes50个RTStorage Conditions:This kit can be stored for 12 months at room temperature (15°C–25°C) under dry conditions. Precipitation may form in Buffer PB at low temperatures; before use, it is necessary to redissolve the buffer in a 37°C water bath and shake it well before use.Precautions:1. The addition of Buffer BL can improve the adsorption capacity of the adsorption column, enhance its uniformity and stability, and eliminate the impact of high temperature/humidity or other adverse environmental factors on the adsorption column. Before use, please check whether Buffer BL is turbid. If turbidity occurs, heat it in a 37°C water bath for a few minutes to restore clarity.2. Buffer PB contains a pH indicator and is yellow, indicating a pH ≤ 7.5.Operating Steps:Before use, add absolute ethanol to Buffer DW2. Please refer to the label on the bottle for the volume to be added.I. Recovering DNA Fragments from Agarose Gels1. Column Equilibration Step: Add 500 µl Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube. (Please use columns processed on the same day)2. Cut the single target DNA band from the agarose gel (remove excess parts as much as possible) and place it in a clean centrifuge tube, then weigh it.3. Add an equal volume of Buffer PB to the gel block (if the gel weighs 0.1 g, its volume can be regarded as 100 µl, so add 100 µl Buffer PB). Incubate in a 50°C water bath for about 10 minutes, gently inverting the centrifuge tube up and down continuously during this period to ensure the gel block is fully dissolved. (If the volume of the gel block is too large, it can be cut into small pieces in advance.)Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after the gel block is completely dissolved, it is best to cool the solution to room temperature before loading onto the column, because the adsorption column has a stronger ability to bind DNA at room temperature. The gel should appear yellow after complete dissolution, and then subsequent operations can be performed. If the color of the solution is orange-red or purple after the gel is completely dissolved, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before proceeding with subsequent operations. (Buffer PB contains a pH indicator. When pH ≤ 7.5, the solution is yellow, and DNA can effectively bind to the membrane. When the pH is high, the solution turns orange-red or purple and needs to be adjusted.)4. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume is larger than 700 µl, it can be added in batches.5. Add 500 µl Buffer DW2 (with absolute ethanol added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Repeat step 5.7. Centrifuge at 12,000 rpm for 3 minutes.8. Place the adsorption column into a clean centrifuge tube, 悬空滴加 an appropriate amount of Buffer EB (Buffer EB is heated at 65°C for 3-5 minutes before use, preheated in advance) to the middle part of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will affect the recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used for elution. The pH of the eluent has a great impact on the elution efficiency. If water is used as the eluent, ensure its pH is within 7.0-8.5 (NaOH can be used to adjust the pH of water to this range). The elution efficiency is low when the pH is below 7.0.II. Recovering DNA from PCR Reaction Solutions or Restriction Enzyme Digestion Solutions1. Column Equilibration Step: Add 500 µl of Buffer BL to the adsorption column (FineBind MinElute DNA Spin Columns) placed in a collection tube. Centrifuge at 12,000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. (Please use columns processed on the same day.)2. Calculate the volume of the PCR reaction solution or restriction enzyme digestion solution, add an equal volume of Buffer PB to it, and mix thoroughly (there is no need to remove paraffin oil or mineral oil).Note: For recovering small fragments < 150 bp, the volume of Buffer PB can be increased to 3 times to improve the recovery rate; after mixing, the solution should appear yellow before proceeding with subsequent operations. If the solution is orange-red or purple, use 10 µl of 3M sodium acetate (pH 5.0) to adjust the color of the solution to yellow before continuing.3. Add the solution obtained in the previous step to the adsorption column (placed in the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Note: The capacity of the adsorption column is 700 µl. If the sample volume exceeds 700 µl, add it in batches.4. Add 500 µl of Buffer DW2 (ensure absolute ethanol is added before use) to the adsorption column, centrifuge at 12,000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.5. Repeat step 4 once.6.Centrifuge at 12,000 rpm for 3 minutes.7. Transfer the adsorption column to a clean centrifuge tube, suspend and add an appropriate amount of Buffer EB (preheat Buffer EB by heating at 65°C for 3–5 minutes before use) to the middle of the adsorption membrane, and let it stand at room temperature for 1 minute. Centrifuge at 12,000 rpm for 1 minute to collect the DNA solution.Note: The volume of the eluent should not be less than 30 µl; a smaller volume will reduce recovery efficiency. If the downstream experiment is sensitive to pH, sterile water can be used as the eluent. The pH of the eluent has a significant impact on elution efficiency. If water is used as the eluent, ensure its pH is within the range of 7.0–8.5 (NaOH can be used to adjust the pH of water to this range); elution efficiency will be low if the pH is below 7.0... Read More | DescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences theDescriptionCholesteryl ester transfer protein (CETP) is present in normal human plasma and transfers neutral lipids from high density lipoproteins (HDL) to very low density lipoprotein (VLDL) and low density lipoprotein (LDL). CETP plays an important role in lipoprotein metabolism and influences the reverse cholesterol transport pathway.Preparation instructionsSuitable for high-throughput screening (HTS), mechanism of action (MOA) studies, and structure-activity relationship (SAR) work in CETP sources.PrincipleThe CETP RP Activity Assay uses a proprietary substrate that enables the detection of CETP-mediated neutral lipid mass transfer. The method is useful for measuring CETP activity in recombinant protein (RP) or purified CETP samples and has a high D... Read More | Inquire | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |