| Description | Inquire | Inquire | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the Apoptosis refers to the cell autonomous and orderly death controlled by genes to maintain the stability of the internal environment. Apoptosis is different from cell necrosis. Apoptosis generally refers to a programmed cell death process that occurs during the development of body cells or under the action of some factors through the regulation of intracellular genes and their products. Cell necrosis is a cell death process that is caused by strong physical and chemical or biological factors to cause disordered changes in cells. The difference between apoptosis and necrosis lies in the characteristic morphological and biochemical changes, including the changes of cell membrane permeability and nuclear chromatin, the contraction of cytoplasm and the loss of membrane asymmetry. The oxazole yellow/pi membrane permeability apoptosis detection kit produced by our company is a dual fluorescence detection kit based on oxazole yellow and PI dyes. This kit is suitable for fluorescence microscopy, flow cytometry, fluorescence microplate reader and other fluorescence detection systems. Oxazole yellow is a non cell membrane penetrating cyanine monomer green fluorescent dye with high affinity for DNA. It basically has no fluorescence when it is not bound to DNA, but can emit bright green fluorescence after binding to DNA. When apoptosis occurs, the permeability of cell membrane changes. At this time, oxazole yellow can enter the cell and bind to DNA, emitting bright green fluorescence. Therefore, it is often used for the detection of apoptosis. It should be noted that oxazole yellow can also stain dead cells, so it needs to be double stained with PI that specifically fluorescently stains dead cells to effectively determine apoptosis. PI (propidium iodide) is a red fluorescent dye that can stain DNA. It is an analog of pyridine bromide that releases red fluorescence after embedding double stranded DNA. Although PI cannot pass through the membrane of living cells, it can cross the damaged cell membrane of dead cells to stain nuclei. Therefore, oxazole yellow combined with PI can be directly used for the detection of apoptosis. Apoptotic cells show green fluorescence, dead cells show both red and green fluorescence positive, and living cells have little or no fluorescence.Components: Components O598364-50T A. Oxazole yellow dye 50 µL B. Propidium Iodide (PI) 50 µLUsage (using flow cytometry as an example):1. Cell preparation(1) For adherent cells, after trypsin digestion, resuspend in culture medium and wash once with pre cooled PBS; The digestion time of trypsin should not be too long to prevent false positives. Note: Digest with trypsin and allow the cells to recover in the optimal cell culture conditions and medium for about 30 minutes, then stain.(2) For suspended cells, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, and wash once with pre cooled PBS.2. Cell stainingSuspend cells in pre cooled PBS, with a recommended cell count of 106 cells/mL per sample. Add 1 µ L Oxazole Yellow and 1 µ L to 1 mL of the samplePI, Gently blow and mix well. Incubate on ice in the dark for 30 minutes. Note: We suggest adding the following two experimental controls:Blank tube: negative control group cells, without dye, used to regulate voltage.Single staining tube: Positive control group cells were treated with only two tubes, Oxazole yellow and PI, for regulating compensation.3. Flow detectionAfter incubation, the sample can be directly detected by flow cytometry, or centrifuged at 1000 rpm for 5 minutes, the supernatant can be aspirated, and the sample can be resuspended in 1 mL of pre cooled PBS for flow cytometry detection. Oxazole yellow can be excited by a 488 nm laser, and the detected fluorescence emission spectrum is around 530 ± 30 nm (FITC channel), while the PI channel emission spectrum is around 617 nm (PI or PE channel).Product parameters:Oxazole yellow dye:ex/em = 491 / 509 nm (bound DNA); Propidium iodine:ex/em = 535 / 617 nm (combined with DMatters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. fluorescent dyes have quenching problems. Please try to avoid light to slow down fluorescence quenching. 3. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Membrane permeability apoptosis assay... Read More | Inquire |