| Description | Acetate Kinase (ACK) is primarily found in microorganisms. It catalyzes the conversion of acetate and ATP to acetyl phosphate and ADP, serving as a key enzyme in bacterial carbon and energy metabolism, and plays a central role particularly in the methanogenesis metabolism of archaea.Assay Acetate Kinase (ACK) is primarily found in microorganisms. It catalyzes the conversion of acetate and ATP to acetyl phosphate and ADP, serving as a key enzyme in bacterial carbon and energy metabolism, and plays a central role particularly in the methanogenesis metabolism of archaea.Assay PrincipleACK catalyzes the synthesis of Acetyl Phosphate and ADP from Sodium Acetate and ATP. Pyruvate Kinase then catalyzes the conversion of ADP and Phosphoenolpyruvate (PEP) to ATP and Pyruvate. Subsequently, Lactate Dehydrogenase catalyzes the reduction of Pyruvate by NADH to produce Lactate and NAD⁺. The rate of oxidation of NADH to NAD⁺, measured by the decrease in absorbance at 340 nm, reflects ACK activity.Component48T96TStorageExtraction Buffer60 mL60 mL×22-8℃ReagentⅠ15 mL30 mL2-8℃ReagentⅡ1EA2EA-20℃. Store in the dark.Reagent III25 µL50 µLNote: It is recommended to perform a pilot experiment with 2-3 samples expected to have significant differences before formal testing.Required Materials and Equipment (Not Provided)Microplate reader or UV spectrophotometer (capable of measuring absorbance at 340 nm)96-well UV plate or micro quartz cuvetteAdjustable pipettes and tipsConstant temperature water bathIce makerCentrifugeDeionized waterHomogenizer (for tissue samples)Reagent PreparationExtraction Buffer: Ready-to-use. Equilibrate to room temperature (RT) before use. Store at 4°C.Caution: Extraction Buffer is toxic and has a pungent odor. It is recommended to handle it within a fume hood.Reagent Ⅰ: Ready-to-use. Equilibrate to RT before use. Store at 4°C.Working Reagent Ⅱ: Prepare immediately before use. For one vial of Reagent Ⅱ, add 11 mL of Reagent Ⅰ and 19.8 µL of Reagent III. Mix thoroughly to dissolve. Prepare fresh for each use. Can be stored protected from light at -20°C for one month.Reagent Ⅲ: Ready-to-use. Equilibrate to RT before use. Store at 4°C protected from light.Sample Preparation*Note: The use of fresh samples is recommended. If not used immediately, samples can be stored at -80°C for up to one month. Control the temperature and time during thawing. If thawed at room temperature, complete the process within 4 hours.*1.Tissues: Weigh approximately 0.1 g of sample. Add 1 mL of Extraction Buffer and homogenize on ice. Centrifuge the homogenate at 15,000 g, 4°C for 10 min. Collect the supernatant and keep it on ice for assay.2.Cells or Bacteria: Collect 5 million cells or bacteria by centrifugation. Wash the pellet with cold PBS, centrifuge, and discard the supernatant. Add 1 mL of Extraction Buffer. Disrupt the cells/bacteria by sonication on ice (200W power, pulse 3s on/10s off, repeat 30 times). Centrifuge the lysate at 15,000 g, 4°C for 10 min. Collect the supernatant and keep it on ice for assay.3.Serum (Plasma) or other liquid samples: Assay directly. If the solution is turbid, centrifuge first and use the supernatant for assay.Note: To determine protein concentration, Aladdin's BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) is recommended.Assay Procedure1.Preheat the microplate reader or spectrophotometer for 30 min. Set the wavelength to 340 nm. Zero the spectrophotometer with deionized water.2.Pre-warm a sufficient volume of the prepared Working Reagent Ⅱ at 37°C (for mammalian samples) or 25°C (for other species) for 5 minutes. Use immediately.3.Assay Setup (perform in a 96-well UV plate or micro quartz cuvette):ReagentTest Well (µL)Sample20Working Reagent Ⅱ180Mix thoroughly immediately after addition. Measure the absorbance at 340 nm at 10 seconds (A₁) and again at 190 seconds (A₂). Calculate ΔA = A₁ - A₂.Note: It is advised to run a pilot test with 2-3 samples showing expected significant variation beforehand. If ΔA is less than 0.05, consider increasing the sample volume or extending the reaction time to 10 or 20 minutes before measurement. If ΔA is greater than 1.0, dilute the sample further with Extraction Buffer (multiply the result by the dilution factor) or reduce the amount of sample used for extraction.Result CalculationNote: Both the derived and simplified calculation formulas are provided and are equivalent. The simplified formulas (in bold) are recommended for final calculation.1. Calculation for 96-Well UV PlateGeneral Parameters for 96-Well Plate:ε (NADH molar extinction coefficient) = 6.22 × 10³ L/mol/cmd (Light path of 96-well plate) = 0.5 cmVₜₒₜₐₗ (Total reaction volume) = 0.0002 L (200 µL)Vₛₐₘₚₗₑ (Sample volume in reaction) = 0.02 mL (20 µL)T (Reaction time) = 3 minVₛₐₘₚₗₑₜₒₜₐₗ (Total extraction volume) = 1 mLCpr (Sample protein concentration, mg/mL)W (Sample mass, g)500 (Cell/Bacteria count in millions: 5 × 10⁶)1.1 Based on Sample Protein Concentration:Definition: One unit of activity is defined as the amount of enzyme that consumes 1 nmol of NADH per minute per mg of protein.Calculation:ACK Activity (U/mg prot) = [ΔA × Vₜₒₜₐₗ ÷ (ε × d) × 10⁹] ÷ (Vₛₐₘₚₗₑ × Cpr) ÷ TSimplified Formula: ACK (U/mg prot) = 1072 × ΔA ÷ Cpr1.2 Based on Sample Mass:Definition: One unit of activity is defined as the amount of enzyme that consumes 1 nmol of NADH per minute per gram of fresh sample.Calculation:ACK Activity (U/g fresh weight) = [ΔA × Vₜₒₜₐₗ ÷ (ε × d) × 10⁹] ÷ (W × Vₛₐₘₚₗₑ / Vₛₐₘₚₗₑₜₒₜₐₗ) ÷ TSimplified Formula: ACK (U/g fresh weight) = 1072 × ΔA ÷ W1.3 Based on Bacterial or Cell Density:Definition: One unit of activity is defined as the amount of enzyme that consumes 1 nmol of NADH per minute per 10⁴ cells/bacteria in the reaction system.Calculation (for 5 million cells in 1 ml extract):ACK Activity (U/10⁴) = [ΔA × Vₜₒₜₐₗ ÷ (ε × d) × 10⁹] ÷ (500 × Vₛₐₘₚₗₑ / Vₛₐₘₚₗₑₜₒₜₐₗ) ÷ TSimplified Formula: ACK (U/10⁴) = 2.144 × ΔA1.4 Based on Liquid Volume:Definition: One unit of activity is defined as the amount of enzyme that consumes 1 nmol of NADH per minute per milliliter of sample.Calculation:ACK Activity (U/mL) = [ΔA × Vₜₒₜₐₗ ÷ (ε × d) × 10⁹] ÷ Vₛₐₘₚₗₑ ÷ TSimplified Formula: ACK (U/mL) = 1072 × ΔA2. Calculation for Micro Quartz CuvetteUse the formulas above but adjust the light path *d* from 0.5 cm to 1.0 cm.Precautions1. Keep samples and all reagents on ice during the assay procedure to prevent denaturation and loss of activity.2. The temperature of the reaction mixture must be maintained at 37°C or 25°C. When using a cuvette, a small beaker filled with deionized water pre-warmed to 37°C or 25°C (placed in a water bath) can be used to hold the cuvette and maintain temperature during the reaction.3. This product is for scientific research use only. It is not intended for clinical diagnosis. For your safety and health, please wear a lab coat and disposable gloves during operation... Read More | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Inquire | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Inquire |