| Description | Acridine Orange (AO) is a metachromatic fluorescent dye whose emission color varies depending on the target it binds to:When binding to double-stranded DNA: It intercalates between base pairs and emits green fluorescence upon excitation (Ex 488 nm, Em 530 nm).When binding to single-stranded RNA or Acridine Orange (AO) is a metachromatic fluorescent dye whose emission color varies depending on the target it binds to:When binding to double-stranded DNA: It intercalates between base pairs and emits green fluorescence upon excitation (Ex 488 nm, Em 530 nm).When binding to single-stranded RNA or lysosomes: It attaches via electrostatic interactions and emits orange-red fluorescence (Em 640 nm).Under a fluorescence microscope, Acridine Orange permeates the membranes of normal cells, staining the nucleus with uniform green or yellow-green fluorescence. In apoptotic cells, due to chromatin condensation and fragmentation into apoptotic bodies, AO stains them with intense, condensed yellow-green fluorescence or fragmented yellow-green particles. In necrotic cells, the yellow-green fluorescence is reduced or absent.Acridine Orange is often used in combination with Propidium Iodide (PI) for dual staining. Since PI stains only dead cells, producing orange-red fluorescence, this method allows differentiation among normal, apoptotic, and necrotic cells.ComponentsA1456513Component50 Test100 TestStorage ConditionQuantity Per TestA1456513ADilution Buffer10 mL50 mL2-8℃0.1 mL per 0.5-1.0 × 10⁶ cellsA1456513BAO Staining Solution100 µL500 µL2-8℃, Protect from light. Do not freeze1 µL per 0.5-1.0 × 10⁶ cellsNote: The recommended number of cells to stain per test is 0.5-1.0 × 10⁶ cells.Procedure1. Preparation of Acridine Orange Staining Solution b. Mix the AO Staining Solution with the Dilution Buffer at a ratio of 1:1000 to prepare the working solution. For example, add 10 µL of AO Staining Solution to 10 mL of Dilution Buffer to obtain 10 mL of Acridine Orange staining solution. 2. Staining with Acridine Orangea. For adherent cells: (a) Gently aspirate the culture medium from the plate. Rinse with PBS for about 10 seconds, then remove PBS. (b) Add Acridine Orange staining solution and incubate at room temperature for 5 minutes. Remove the staining solution and rinse with PBS for about 10 seconds. Repeat the rinse once. Note: For adherent cells cultured in a 6-well plate with a confluence exceeding 80%, it is recommended to add the staining working solution at a volume of 1 mL per well. This volume can be optimized based on the specific experimental system.(c) Incubate at room temperature for 5 minutes. (c) Add an appropriate amount of cell culture medium, staining buffer, or other suitable solution to cover the well bottom. Observe under a microscope. Depending on the detection requirements, green fluorescence can be observed at Ex/Em = 488/530 nm, and red fluorescence can be observed at Ex/Em = 540/640 nm. Alternatively, measure fluorescence intensity using a fluorescence microplate reader with bottom-reading capability.b. For suspension cells: (a) Take 1 mL of cell suspension. Centrifuge at 500g for 5 minutes at room temperature. Gently aspirate the medium, resuspend in PBS, and centrifuge again at 500g for 5 minutes. Remove PBS. (b) Add an appropriate amount of Acridine Orange staining solution to achieve a cell density of approximately 10⁶ cells/mL.(c) Incubate at room temperature for 5 minutes. (d) A drop of the sample was directly applied onto a glass slide, covered with a coverslip, and examined under a microscope. Depending on the detection requirements, green fluorescence can be observed at Ex/Em = 488/530 nm, and red fluorescence can be observed at Ex/Em = 540/640 nm. Alternatively, after staining, analyze directly by flow cytometry or measure fluorescence with a microplate reader.Note: Centrifugation to remove staining solution can reduce background fluorescence. For suspension cells or adherent cells in suspension, consider reducing the AO staining solution concentration by 2–5 times and shortening the staining time to 2 minutes.Precautions1. AO Staining Solution is toxic. Handle with care. 2. For your safety and health, wear a lab coat and disposable gloves. 3. Fluorescent dyes are susceptible to quenching. It is recommended to complete detection on the same day after staining... Read More | Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20Product contentG665801Component100 TStorageG665801A2×GoldStar Probe One Step Buffer1.4 mL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801BGoldStar Probe One Step EnzymeMix100 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801C50×High ROX50 µL-20℃. Avoid freeze/ Thaw cycle. Protect from light.G665801DRNase-Free Water1.5 mL-20℃. Avoid freeze/ Thaw cycle. Product Introduction This product is a specialized kit for one-step Real-Time RT-qPCR using the probe method (TaqMan, Molecular Beacon, etc.). When using this product for Real Time RT-qPCR reaction, reverse transcription and quantitative PCR are carried out in the same reaction system, and there is no need to add reagents or open the cap of the tube during the reaction process, which avoids contamination and improves the experimental efficiency at the same time. With high detection sensitivity, strong fluorescence signal and high signal-to-noise ratio, this product is very suitable for the detection of RNA viruses and other trace RNA. The special buffer system contained in this product can maximize the effectiveness of reverse transcriptase and DNA polymerase at the same time and improve the efficiency of the reaction. A wider linear range can be obtained with this product, more accurate quantification of the target gene, good reproducibility and high confidence.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument. Instruments that do not require ROX calibration (G665836) Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others. Instruments that require High ROX calibration (G665801) ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1.Before using the reagents in this kit, please mix them gently by turning them up and down to avoid foaming as much as possible, and use them after brief centrifugation.2.This product uses RNA as the template for one-step RT-PCR experiment, RNase contamination should be avoided during operation, it is recommended to operate RNA in a special area, use special instruments and consumables, the operator with a mask and disposable gloves and often change the gloves, the experiment-related consumables should be processed with 0.1% DEPC (diethyl ether pyrocarbonate) aqueous solution for 12 hours at 37℃, and autoclaved for 30 minutes before use. The consumables should be treated with 0.1% DEPC (diethylpyrocarbonate) aqueous solution at 37℃ for 12 hours and autoclaved for 30 minutes.3.Repeated freezing and thawing of each reagent in this kit should be avoided as much as possible; repeated freezing and thawing may degrade the product performance.4.This kit must use specific primers, the choice of primers can be selected according to specific experiments, the good or bad primer design directly affects the results of RT-qPCR reaction, the design of primers need to consider the GC content, primer length, primer position, the secondary structure of the PCR product and other factors, it is recommended to use a professional primer design software for design.5.This kit is recommended to use specific probes, and it is recommended to use professional design software for designing.UsageThe following examples are conventional reaction systems and conditions, which should be improved and optimized according to the different templates, primer structures and target fragment sizes in actual operation. (Please prepare the reaction solution on ice.)1. Dissolve RNA template, primers, 2× GoldStar Probe One Step Buffer, GoldStar Probe One Step EnzymeMix and RNase-Free Water and set aside on ice.2. PCR reaction system:reagents25µl reaction systemfinal concentration2×GoldStar Probe One Step Buffer12.5µl1×Forward Primer, 10µM0.5µl0.2µM¹⁾Reverse Primer, 10µM0.5µl0.2µM¹⁾Probe, 10µM0.5µl0.2µM²⁾GoldStar Probe One Step EnzymeMix1.0µl RNA TemplateXµl10pg-100ng³⁾50 x Low ROX or High ROX (optional)⁴⁾0.5µl1×RNase-Free WaterUp to 25µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of RNA template is 10pg-100ng as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be diluted in gradient to determine the optimal amount of template to use.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.3. Mix well, centrifuge briefly, and collect the solution at the bottom of the tube.4.RT-PCR reaction conditions:Note: 1) The hot start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 5-10min. 2) It is recommended to use the two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out the three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | functional group:carboxylic acid Description:Liposome Kit has been used for the preparation of liposomes. Composition:Cholesterol, 9 µmol/package L-α-Phosphatidylcholine (egg yolk), 63 µmol/package Stearylamine, 18 µmol/package | Inquire | Product content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligationProduct content Q665687Component100 TStorageQ665687AQuick T4 DNA Ligase (15 U/µL)100 µL-20℃. Avoid freeze/thaw cycle.Q665687B2×Quick Ligation Reaction Buffer5×200 µL-20℃. Avoid freeze/thaw cycle. Product IntroductionThe Quick Ligation Reaction Kit allows ligation of DNA sticky or flush ends in 5 minutes at room temperature (25°C). The kit contains Quick T4 DNA Ligase and 2×Quick Ligation Reaction Buffer optimized for fast and efficient DNA ligation.The ligation efficiency of Quick Ligation is equivalent to 1 hour of conventional ligation with T4 DNA Ligase. The Quick Ligation products can be used directly in routine bacterial transformation experiments.matters needing attention1. This kit enables most of the linkage reactions to reach the reaction endpoint within 5 minutes or less at 25°C. Increasing the reaction time will not enhance the reaction efficiency. If you use the rapid connection reaction after 1 hour, the conversion efficiency will be significantly reduced; if the rapid connection reaction at 25 ℃ overnight, the conversion efficiency will drop to 75%.2. 2×Quick Ligation Reaction Buffer contains ATP, which should be thawed on ice and mixed thoroughly before use. It is recommended to freeze the buffer in small tubes for the first time, so as to avoid repeated freezing and thawing, which will affect the efficiency of DNA ligation.3. Since T4 DNA Ligase contains glycerol, which is sticky and easy to hang on the wall, it is recommended to collect the liquid to the bottom of the tube by centrifugation for a short period of time before use, and the tip of the lance should not go too deep into the liquid surface when taking samples to avoid sticking to the tip of the lance and causing losses.4. If the quick ligation product is used for electrotransformation, the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation, and it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation.Usage1. The reaction solution was prepared according to the following system:*The amount of Insert DNA used: the molar ratio of Vector DNA and Insert DNA is generally 1:3-1:8, and the appropriate molar ratio of Vector DNA and Insert DNA can be selected according to the experimental situation.Calculation of DNA molar number: DNA molar number (nmol)=DNA mass (ng)/( 660daltons x number of inserted DNA bases bp).2. mix gently and centrifuge briefly. react at 25°C for 5 minutes.Note: The reaction time should not exceed 15 minutes, otherwise the connection efficiency will be reduced.3. Do not perform heat inactivation reactions. Centrifuge instantly and collect the solution from the wall to the bottom of the tube.Note: Heat inactivation significantly reduces transformation efficiency due to the presence of PEG in the buffer.4. After the reaction, store the DNA ligation product at 0-4℃, and then carry out transformation experiments; you can also store the DNA ligation product at -20℃.Note: When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.5. Heat shock the ligation product to transform 50 µl of receptor cells or take 1-2 µl of ligation product to electroshock transform 50 µl of receptor cells.Note: 1) When transforming by chemical method, do not add more than 10% of the volume of the receptor cell for the ligation product.(2) If the quick ligation product is used for electrotransformation, it is recommended to use a centrifugal column to purify the ligation product from DNA before electrotransformation because the PEG in the quick ligation reaction system will affect the efficiency of electrotransformation... Read More |