| Description | Inquire | This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, This product is a cDNA first strand synthesis kit specially prepared for the first step experiment of two-step RT-PCR. This product contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including HiFi MMLV reverse transcriptase, reaction buffer, primers, dNTP, etc. The mutated HiFi MMLV reverse transcriptase RNase H activity is deficient, reducing RNA degradation in reverse transcription reactions and making it easier to obtain full-length cDNA. HiFi MMLV reverse transcriptase has strong thermal stability and can yield high yields of cDNA, making it simple and convenient to use. This system has high compatibility with subsequent PCR and quantitative PCR experiments, and is suitable for various DNA polymerase reactions. H665693 Component 100 T Storage H665693A HiFi-MMLV, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665693B 5×RT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665693C Primer Mix 240 µL -20℃. Avoid freeze/thaw cycle. H665693D dNTP Mix, 2.5 mM Each 500 µL -20℃. Avoid freeze/thaw cycle. H665693E DTT, 0.1 M 240 µL -20℃. Avoid freeze/thaw cycle. H665693F RNase-Free Water 1 mL -20℃. Avoid freeze/thaw cycle. Product features:·RNase H -: Mutated HiFi MMLv reverse transcriptase with reduced RNase H activity, making it easier to obtain full-length cDNA.·Easy to use: The reagent kit contains all the reagents required for reverse transcription, except for RNA templates.Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.Usage:Attention: 10 ng-5 µ G Total RNA can establish 20 µ Reaction system, if the total RNA content is greater than 5 µ g. Please expand the reaction system proportionallyi Steps for reverse transcription:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare a reaction system according to the following table, with a total volume of 20 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / RNase-Free Water up to 20 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random Primer3. Vortex shake and mix well, briefly centrifuge to collect the solution on the pipe wall to the bottom of the pipe. 4. Incubate at 42 ℃ for 30-50 minutes and 85 ℃ for 5 minutes. After the reaction is complete, centrifuge briefly and cool on ice.5. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time.ii If the reverse transcription efficiency is low, or the RNA template secondary structure is complex and the GC content is high, the following steps are recommended:1. Dissolve RNA templates, primers, dNTP Mix, DTT, RT Buffer, HiFi MMLV, and RNase Free Water and place on ice for later use.2. Prepare the reaction system according to the following table, with a total volume of 13 µ L. Reagent 20 µlReaction system Final concentration dNTP Mix,2.5 mM Each 4 µl 500 µM Each Primer Mix 2 µl / RNA Template X µl 1 ng-5 µg RNase-Free Water up to 13 µl / 3. Incubate at 70 ℃ for 10 minutes and quickly ice bath for 2 minutes.4. Centrifuge briefly to collect the solution on the tube wall to the bottom of the tube.5. Continue to add the following reagents to the above reaction solution: Reagent 20 µlReaction system Final concentration 5×RT Buffer 4 µl 1× DTT,0.1 M 2 µl 10 mM HiFi-MMLV,200 U/µl 1 µl / Attention:1) If the initial amount of RNA is less than 50 ng, it is recommended to add RNA enzyme inhibitors (RNAsin). This kit is not provided.2) Primer Mix is formulated from Oligo (dT) and Random primer.6. Gently blow and mix well, incubate at 42 ℃ for 50 minutes, and incubate at 85 ℃ for 5 minutes.7. After the reaction is complete, centrifuge briefly and cool on ice.8. Reverse transcripts can be directly used for PCR reactions and fluorescence quantitative PCR reactions, or stored at -20 ℃ for a long time... Read More | Inquire | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | This reagent kit is designed based on the principle that biotin and Streptavidin have a strong affinity. After the primary antibody of rabbit or mouse origin binds to the corresponding target antigen, the biotinylated antibody in this kit • • Rabbit/mouse universal secondary antibody This reagent kit is designed based on the principle that biotin and Streptavidin have a strong affinity. After the primary antibody of rabbit or mouse origin binds to the corresponding target antigen, the biotinylated antibody in this kit • • Rabbit/mouse universal secondary antibody specifically binds to the primary antibody; The biotin labeled on the secondary antibody binds to streptavidin labeled with peroxidase (HRP), forming an antigen-specific primary antibody biotinylated secondary antibody streptavidin complex labeled with HRP. HRP can catalyze substrate colorimetry, thereby inferring the presence and distribution of the tested antigen. The biotinylated secondary antibody and SA-HRP used in this reagent kit all adopt optimized labeling and purification techniques, which make their staining more sensitive and have a lower background. They are suitable for detecting formalin fixed paraffin embedded tissue sections, as well as frozen sections, cell slides, freshly prepared blood smears, etc. The rabbit/mouse universal Streptavidin HRP kit is suitable for use with aladdin ready to use or concentrated antibodies. Composition:Note: This reagent kit is only suitable for IHC experiments where the primary antibody is an immune or mouse derived antibodNotes:1. Add 1 drop (approximately 50) to each slice µ l) Calculation: 3ml can make 60 slices, and 18ml can make 360 slices.2.For tissues with abundant endogenous biotin content, it is best to use endogenous biotin blockers for blocking when using this kit.3. DAB working solution is prepared and used immediately, and the prepared working solution is effective within 1 hour in the dark at 2-8 ° C.4. During the experiment, avoid drying the tissue slices, so the amount of working fluid used during each incubation step must be sufficient to ensure complete coverage of the tissue sample, and incubation should be carried out in a wet box as much as possible.5. To obtain the best experimental results, please make sure to optimize the experimental conditions and reagent dosage.6. DAB is a suspected carcinogen, please take necessary protective measures when using it. 7. This product is only for scientific research and cannot be used for human reactions or treatments.Operation steps:1. Routine processing of samples such as paraffin or frozen tissue sections or cell slides to be tested.1) Preparation for staining of tissue sections or cell slides: a. Dewaxing and hydration of paraffin sections: bake at 60 º C for 1 hour, dewaxing twice with xylene for 5 minutes each time; Then immerse in gradient ethanol (anhydrous ethanol anhydrous ethanol 95% 85% 75% ethanol) and distilled water for 5 minutes each for hydration. b. Frozen sections and cell climbing sections (or climbing sections) were soaked in 0.01 M pH 7.4 PBS and washed 3 times for 5 minutes. Then cover the tissue (or cells) with 0.1% Triton X-100 and infiltrate for 15 minutes. Wash twice with 0.01 M pH 7.4 PBS for 5 minutes.2) Antigen repair of paraffin sections: In most cases, high-pressure repair with citric acid buffer is suitable for paraffin tissue sections. Preparation of repair solution: Add 10 ml of citric acid buffer (IHC antigen repair solution, 100 x) to 1 L of deionized water, and mix well. Repair process: The repair solution is added to a high-pressure cooker, and the repaired slices are immersed in the repair solution (must have no tissue). Cover the pressure cooker cover, heat until evenly sprayed with steam, and start timing from the spraying. After 1-2 minutes, the pressure cooker leaves the heat source and cools naturally to room temperature. Remove the slices, rinse with distilled water, and rinse twice with PBS (0.01 M pH 7.4) for 3 minutes each time.2. Add an appropriate amount of Solution A white solution, which is an endogenous peroxidase blocking solution, and incubate at room temperature for 10 minutes, then rinse thoroughly with PBS.3. Add an appropriate amount of Solution B white solution dropwise, which is sealed with normal sheep serum working solution. Incubate at room temperature for 10 minutes and shake dry.4. Add an appropriate amount of primary antibody working solution (commercial ready to use antibodies or concentrated antibodies diluted in appropriate proportions) dropwise, incubate according to experimental requirements, and then rinse thoroughly with PBS.5. Add an appropriate amount of Solution C yellow solution, namely biotin labeled sheep anti rabbit/mouse secondary antibody working solution, incubate at room temperature for 10 minutes, and rinse thoroughly with PBS.6. Add an appropriate amount of Solution D red solution, which is HRP labeled streptavidin. Incubate at room temperature for 10 minutes and rinse thoroughly with PBS.7. Preparation of DAB color working solution: According to the required amount, mix DAB-A and DAB-B in a volume ratio of 1:19 to obtain DAB color working solution. Alternatively, one drop (approximately 50) can be added per milliliter of reagent B µ l) Reagent A, mix well.8. Color development: Add an appropriate amount of DAB color development working solution to the tissue section or cell slide that needs to be developed, and the color development time is generally 1-5 minutes. Observe and control the color development time under a microscope. When the optimal color development effect is achieved, rinse with tap water to terminate the color development. The colored slices are re stained, dehydrated and transparent, and can be stored for a long time after sealing... Read More |