| Description | Polyphenol Oxidase (PPO, EC1.10.3.1) is widely found in the plastids of plants, fungi, and insects. It is a copper-containing oxidase that can oxidize monophenols and diphenols to produce quinones, leading to browning. It is closely related to fruit and vegetable processing, tea quality, and Polyphenol Oxidase (PPO, EC1.10.3.1) is widely found in the plastids of plants, fungi, and insects. It is a copper-containing oxidase that can oxidize monophenols and diphenols to produce quinones, leading to browning. It is closely related to fruit and vegetable processing, tea quality, and tissue culture. The Plant Polyphenol Oxidase (PPO) Activity Assay Kit (Catechol, Micro method) provides a simple method to detect the activity level of polyphenol oxidase (PPO) in plant tissue samples.Detection Principle: Polyphenol oxidase (PPO) in the sample catalyzes the oxidation of catechol to produce quinones, which have a characteristic absorption peak at 410 nm. The rate of increase in absorbance at 410 nm is measured to calculate PPO activity.P1501774Component48T96TStorageP1501774AExtraction Buffer60 mL120 mL2-8℃P1501774BReagentⅠ24 mL48 mL2-8℃P1501774CReagentⅡ6 mL12 mL2-8℃. Store in the dark.Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.User-Prepared Instruments and ReagentsMicroplate reader or visible spectrophotometer (capable of measuring absorbance at 410 nm)96-well plate or micro glass cuvettes, adjustable micropipettes and tipsRefrigerated centrifuge, ice maker, constant temperature water bathDeionized waterHomogenizerExperimental Procedure1. Reagent PreparationReagent NameReagent PreparationNotesExtraction BufferReady-to-use; Equilibrate to room temperature before use.Store at 4°C.ReagentⅠReady-to-use; Equilibrate to room temperature before use.Store at 4°C.ReagentⅡReady-to-use; Equilibrate to room temperature before use.Store at 4°C protected from light; Toxic, handle with care.2. Sample PreparationNote: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for one month.2.1 Preparation of Crude Enzyme ExtractHomogenize the plant sample in ice-cold Extraction Buffer with a mass (g) to volume (mL) ratio of 1:5 to 1:10 (recommended: 0.1 g tissue + 1 mL Extraction Buffer). Centrifuge the homogenate at 8,000 g, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.2.2 Boiled Sample ControlTake an appropriate amount of the crude enzyme extract and heat it in a boiling water bath for 5 minutes (seal to prevent moisture loss). Cool to room temperature.3. Assay Steps3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 410 nm. For spectrophotometers, zero the instrument with deionized water.3.2 Sample Measurement (Add reagents sequentially into 1.5 mL microcentrifuge tubes):ReagentControl Tube (µL)Test Tube (µL)Boiled Sample500Sample (supernatant)050ReagentⅠ200200ReagentⅡ50503.3 Mix thoroughly. Incubate in a 25°C water bath for 10 minutes, then immediately transfer to a boiling water bath for 10 minutes. After mixing, centrifuge at 5,000 g, 25°C for 10 minutes. Collect the supernatant. Transfer 200 µL of the supernatant to a micro glass cuvette or 96-well plate. Measure the absorbance of both the Test tube and Control tube at 410 nm. Calculate ΔA = Atest - Acontrol.Note:Each test tube requires a corresponding control tube.It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment.The optimal reaction temperature for PPO may vary slightly among different samples and can be adjusted between 25-37°C.If the sample absorbance is less than 0.02, consider increasing the sample volume appropriately. If the sample absorbance is greater than 1, it is advisable to dilute the sample before assay.4. Calculation of ResultsNote: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.4.1 Calculation Formula when using a 96-well plate:Unit Definition: One unit of enzyme activity is defined as the amount that causes a change of 0.005 in absorbance at 410 nm per minute per gram of tissue per mL of reaction mixture.PPO Activity (U/g fresh weight) = ΔA × Vtotal reaction÷ (W × Vsample / Vtotal sample ) ÷ 0.005 ÷ T = 120 × ΔA / W4.2 Calculation Formula when using a micro glass cuvette:Unit Definition: One unit of enzyme activity is defined as the amount that causes a change of 0.01 in absorbance at 410 nm per minute per gram of tissue per mL of reaction mixture.PPO Activity (U/g fresh weight) = ΔA × Vtotal reaction ÷ (W × V sample / Vtotal sample ) ÷ 0.01 ÷ T = 60 × ΔA / WParameter Definitions:Vtotal reaction: Total volume of the reaction system (0.3 mL)Vsample : Volume of sample added to the reaction (0.05 mL)Vtotal sample : Volume of Extraction Buffer added during homogenization (1 mL)T: Reaction time (10 minutes)W: Sample weight (g)PrecautionsThis product is for research use only. Not for use in clinical diagnosis. For your safety and health, please wear lab coats and disposable gloves during operation... Read More | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the transposase-based second-generation sequencing Rapid DNA Library Construction Kit, designed for Illumina platform library construction, which contains 8 primers at the N5 end and 12 primers at the N7 end, which can be used to prepare 96 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The prepared libraries can be sequenced on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes; tips: It is recommended to use high-quality filtration tips to prevent contamination of reagent kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501-N508 Primers for IlluminaIndex N701-N712 Primers for Illumina... Read More | Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the Products contentN665978Component384 TStorageN665978AIndex N502-N522 Primers for Illumina 16×24 µL-20℃. Avoid freeze/thaw cycle.N665978BIndex N701-N729 Primers for Illumina24×16 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion to the transposase-based rapid DNA library construction kit, designed for Illumina platform library construction. It contains 16 N5 primers and 24 N7 primers, which can be used to prepare 384 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq.Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes; Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.procedure For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol. Index N502-N522 Primers for Illumina Index N701-N729 Primers for Illumina... Read More | Inquire |