| Description | Inquire | Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and Product content: G665990Component200 TStorageG665990ABuffer PG100 mLRTG665990BBuffer PS60 mLRTG665990CBuffer PW (concentrate)50 mLRTG665990DBuffer EB30 mLRTG665990ESpin Columns DM with Collection Tubes200 EART Product Introduction:This kit uses a new silicon-based plasma membrane technology and reagent formulation. Through the unique centrifugal adsorption column and the DNA washing elution step, 100 bp-10 kb DNA fragments can be recovered and purified from ordinary or low melting point agarose gel. The sol speed is fast and the recovery rate is high. The sol solution contains a pH indicator, which can be used to determine whether the sol recovery has reached the optimal state based on its color. Each adsorption column can adsorb up to 10 µ G DNA, while effectively removing impurities such as primers, enzymes, mineral oil, and agarose. The purified and recovered DNA has high purity and concentration, good integrity, and can be directly used for molecular biology experiments such as sequencing, linking and transformation, labeling, and in vitro transcription.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.2. Before use, please check the Buffer PG. If crystallization or precipitation occurs, it can be left in a 37 ℃ water bath for 3-5 minutes to restore clarity.3. It is best to use a new electrophoresis buffer during electrophoresis to avoid affecting the electrophoresis and recovery efficiency; The following experiment requires high requirements, please use TAE electrophoresis buffer as much as possible.4.When cutting glue, the UV irradiation time should be as short as possible to avoid damage to DNA.5. The recovery rate is related to the initial amount of DNA and the elution volume. The smaller the initial amount, the smaller the elution volume, and the lower the recovery rate.6. Preheat the water bath to 50 ℃.7. Buffer PG contains a pH indicator. When the pH is ≤ 7.5, the color of the solution is yellow, and DNA can effectively bind to the membrane. When the pH is too high, the color of the solution turns orange red and purple, which needs to be adjusted.8. All centrifugation steps can be performed at room temperature.Operation steps:1. Cut the single purpose DNA strip from the agarose gel (try to cut the excess), put it into a clean centrifuge tube (self prepared), and weigh and calculate the weight of the gel (record the weight of the centrifuge tube in advance).Attention: If the volume of the adhesive block is too large, it can be cut into small pieces.2. Add one time of the volume of Buffer PG (if the gel weighs 100 mg, its volume can be regarded as 100 µ l. And so on.3.50 ℃ water bath and gently invert the centrifuge tube every 2-3 minutes until the sol turns yellow to ensure full dissolution of the gel block. If there are still unsolved glue blocks, you can add some more sol solution or continue to let it stand for a few minutes until the glue blocks are completely dissolved.Note: 1) After the gel is completely dissolved, the gel solution is yellow, and subsequent operations can be carried out; If the glue solution is orange red or purple, 10-30 can be added to the glue solution µ 3 M sodium acetate (pH 5.0), adjust the color of the solution to yellow before proceeding with subsequent operations.2) After the gel block is completely dissolved, it is best to lower the temperature of the gel solution to room temperature before loading the column. The adsorption column has a weaker ability to bind DNA at higher temperatures.4. (Optional step) When the recovered fragment is less than 300 bp, add 1/2 of the gel volume of isopropanol, and mix it upside down (if the gel weighs 100 mg, add 50 µ Isopropanol of L.5. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ Centrifuge at 13000 rpm (~16200 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.6. Add the solution obtained from steps 3 or 4 to the adsorption column that has been loaded into the collection tube, let it stand at room temperature for 2 minutes, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Attention: The volume of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.7. Add 450 to the adsorption column µ LBuffer PW (please check if anhydrous ethanol has been added before use), centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.Note: If purified DNA is used for salt sensitive experiments (such as flat end ligation or direct sequencing), it is recommended to add Buffer PW and let it stand for 2-5 minutes before centrifugation.8. Repeat step 7.9.13000 rpm for 1 minute and discard the waste liquid from the collection tube.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).10. Place the adsorption column into a new 1.5 ml centrifuge tube (provided by oneself), and add 50 drops to the middle position of the adsorption membrane in the air µ L Buffer EB, leave at room temperature for 2 minutes. Centrifuge at 13000 rpm for 1 minute and collect DNA solution- Store DNA at 20 ℃.Attention:1) To improve the recovery of DNA, the solution obtained by centrifugation can be re dropped onto the adsorption column, left at room temperature for 2 minutes, and centrifuged at 13000 rpm for 1 minute.2) The elution volume should not be less than 30 µ l. A small volume will affect the recovery efficiency.3) When recovering DNA fragments larger than 10 kb, Buffer EB should be preheated in a 50 ℃ water bath to increase recovery efficiency.Note: This reagent kit is also suitable for the purification and recovery of PCR products. Add an equal volume of Buffer PG to the PCR reaction solution and mix thoroughly (for small fragments with a recovery of less than 150bp, the solution volume can be increased to three times to improve the recovery rate). Follow step 5 above for further operations... Read More | H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT H665581 Component 100 T Storage H665581A gDNA Eraser 50 µL -20℃. Avoid freeze/thaw cycle. H665581B 10×gDNA Eraser Buffer 120 µL -20℃. Avoid freeze/thaw cycle. H665581C HiFiScript, 200 U/µL 100 µL -20℃. Avoid freeze/thaw cycle. H665581D 5×ScriptRT Buffer 500 µL -20℃. Avoid freeze/thaw cycle. H665581E Primer Mix 120 µL -20℃. Avoid freeze/thaw cycle. H665581F RNase-Free Water 2×1 mL -20℃. Avoid freeze/thaw cycle.Product IntroductionThis product is a kit for removing genomic DNA for reverse transcription. The kit removes genomic DNA in 2 minutes at 42°C. Since the reverse transcription reagent contains a component that inhibits gDNA Eraser, cDNA can be synthesized directly by reverse transcription of gDNA Eraser-treated samples.The kit is equipped with a new high-efficiency reverse transcription enzyme, HiFiScript, with novel mutation sites that dramatically increase the transcriptional activity of the enzyme, resulting in higher efficiency and yield of cDNA first-strand synthesis. The first strand of cDNA can be synthesized with higher efficiency and yield, and the first strand of cDNA can be synthesized from pg total RNA or mRNA. If the reverse transcription product cDNA is used for downstream fluorescence quantitative detection, the reverse transcription reaction can be completed at 42℃ in 15 minutes. This kit is suitable for the synthesis of first-strand cDNA and subsequent RT-PCR, RT-qPCR, and the construction of full-length cDNA libraries.Product Features1. Rapid genome removal: contains gDNA Eraser for genomic DNA removal, which removes genomic DNA in just 2 minutes.2. Rapid reverse transcription: 15 minutes to obtain fluorescent quantitative PCR template cDNA first strand synthesis.3. High sensitivity: cDNA first strand can be synthesized using pg-level total RNA or mRNA templates.4. Highly efficient reverse transcription: Novel mutation sites dramatically increase enzyme activity, resulting in higher yields of cDNA.matters needing attention1. During operation, RNase contamination should be avoided to prevent RNA degradation or cross-contamination in the experiment. It is recommended that operators wear masks and disposable gloves and change the gloves frequently, and use specialized instruments and consumables.2. The reverse transcription system is prepared and operated on ice to prevent degradation of RNA. Store the kit enzymes at -20ºC as soon as possible after use and try to avoid repeated freezing and thawing.3. The reaction system can be scaled up to a maximum of 1 µg of total RNA in 10 µl of reaction system.4. Primer Mix is prepared by Oligo(dT) and Random primer, and Oligo-dT Primer or Gene Specific Primer can also be used according to the experimental needs.5. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).6. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65°C for 5 minutes immediately on ice prior to the manipulation step and centrifuge briefly before proceeding to the next step.UsageThaw template RNA on ice; place kit components on ice immediately after thawing at room temperature. Each solution was mixed by vortexing and shaking before use and briefly centrifuged.I. Genomic DNA removal reactions1. Prepare the reaction system according to the following table on ice in a total volume of 10 µl. To ensure the accuracy of the reaction solution preparation, prepare the premixed system in the amount of reaction number + 2 before dispensing it into each reaction tube and finally adding the RNA sample.Note: 1) If the amount of total RNA is greater than 1µg, scale up the reaction system proportionally. If the amount of starting RNA is less than 50ng, it is recommended to add RNAase inhibitor (RNasin).2. Mix by vortex shaking and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. Incubate at 42°C for 2 minutes (this can be extended to 30 minutes for room temperature reactions).4.At the end of the reaction, centrifuge briefly and place on ice to cool.II. Reverse transcription reaction1. Prepare the reaction system on ice according to the following table. In order to ensure the accuracy of the reaction solution configuration, first prepare a premixed solution in the amount of number + 2, and then dispense 10 µl into each reaction tube, take 10 µl of the prepared premixed solution and add it to the reaction tube of step 1 where the de-etching of the genome has been completed.Note: 1) Oligo-dT Primer or Gene Specific Primer can be used according to the needs of the experiment, it is recommended to use 50 pmol of Oligo-dT Primer or 2 pmol of Gene Specific Primer for 20 µl reaction system.2. Mix well and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.3. cDNA synthesis reaction conditions:1) If fluorescent quantitative PCR assay is performed downstream, incubate at 42°C for 15 minutes and 85°C for 5 minutes.2) If downstream for normal PCR assay, incubate at 42°C for 30-50 minutes and 85°C for 5 minutes. Note: For templates with complex secondary structure or high GC content, the reverse transcription temperature can be increased to 50°C to enhance reverse transcription efficiency.4. At the end of the reaction, centrifuge briefly and place on ice before proceeding with subsequent PCR or fluorescence quantitative PCR, or place at -20°C if prolonged storage is required.Note: When performing Real-time PCR reactions, the amount of reverse transcription product added should not exceed 1/10 of the total volume of the PCR reaction... Read More | Product contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with highProduct contentcomponent50T200TBuffer LP125mL100mLBuffer LP210mL40mLBuffer LP3 (concentrate)21ml84mlBuffer GW2 (concentrate)15mL75mlBuffer GE15mL60mLRNase A(10 mg/ml)300µl1.25mLSpin Columns DM with Collection Tubes50200ProductsThis kit uses centrifugal adsorption columns with high efficiency and specific binding of nucleic acids and a unique buffer system, which is suitable for extracting genomic DNA from a wide variety of different fresh or frozen plant tissues with maximum removal of impurities from the plant tissues. The kit eliminates the need for phenol/chloroform extraction and is safe to handle. The extracted genomic DNA fragments are large, high purity, stable and reliable quality, suitable for PCR, fluorescence quantitative PCR, molecular labeling, library construction and other experiments.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes1. Repeated freezing and thawing of the sample should be avoided, as this may result in smaller fragments of extracted DNA and a decrease in the amount extracted.2. Anhydrous ethanol should be added to Buffer LP3 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use. Check Buffer LP1 and Buffer LP2 for crystallization or precipitation before use. If crystallization or precipitation occurs, re-dissolve Buffer LP1 and Buffer LP2 in a 56°C water bath. Procedure1. Take about 100mg of fresh plant tissue or about 20mg of dry weight tissue and add liquid nitrogen to grind it fully.2. Collect the ground powder into a centrifuge tube (self-provided), add 400 µl Buffer LP1 and 6 µl RNase A (10 mg/ml), vortex and oscillate for 1 minute, and leave it at room temperature for 10 minutes to allow for full cleavage.Note: 1) Use vortex shaking or pipette blowing to fully lyses the tissue, incomplete tissue lysis will affect the final DNA yield. 2) Do not mix Buffer LP1 with RNase A prior to use.3. Add 130 µl Buffer LP2, mix well and vortex for 1 minute.4. Centrifuge at 12,000 rpm (~13,400 x g) for 5 minutes and transfer the supernatant to a new centrifuge tube (supplied).5. Add 1.5 times the volume of Buffer LP3 (check that anhydrous ethanol has been added before use) and mix thoroughly (e.g., 500 µl filtrate to 750 µl Buffer LP3).Note: Buffer LP3 should be mixed immediately after addition; precipitation may occur but will not affect subsequent experiments.6. Add all of the solution and precipitate obtained in the previous step to the adsorption columns (Spin Columns DM) that have been loaded into the collection tubes, if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tubes, and put the columns back into the collection tubes.7. Add 500 µl of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.Note: If the adsorbent membrane appears green, add 500 µl of anhydrous ethanol to the adsorbent column, centrifuge the column at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.8. Repeat step 7.9. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).10. Place the adsorption column in a new centrifuge tube (supplied), add 50-100 µl of Buffer GE or sterilized water dropwise to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, and centrifuge it at 12,000 rpm for 1 minute to collect the DNA solution. -The DNA solution was collected by centrifugation at 12,000 rpm for 1 min.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if you use water as the eluent, you should ensure that the pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of the water to this range), and when the pH value is lower than 7.0, the elution efficiency is not high.2) Incubation at room temperature for 5 minutes prior to centrifugation increases yield.(3) If the final concentration of DNA is to be increased, the DNA eluate obtained in step 10 can be re-added to the adsorbent membrane and repeat step 10; if the elution volume is less than 100µl, the final concentration of DNA can be increased, but it may reduce the total DNA yield. If the amount of DNA obtained is less than 1µg, 50µl Buffer GE is recommended for elution.4) Because DNA stored in water is subject to acidic hydrolysis, for long-term storage, elution with Buffer GE and storage at -20°C are recommended... Read More | O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water O665690 Component 50T Storage O665690A DNase I 1000 U -20℃.Avoid freeze/thaw cycle. O665690B 10×Reaction Buffer 1000 µL -20℃.Avoid freeze/thaw cycle. O665690C Buffer RLS 40 mL RT O665690D Buffer RW1 40 mL RT O665690E Buffer RW2 (concentrate) 11 mL RT O665690F RNase-Free Water 10 mL RT O665690G Spin Columns FS with Collection Tubes 50 EA RT O665690H Spin Columns RM with Collection Tubes 50 EA RT O665690I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTProduct IntroductionThis kit is suitable for extracting RNA from a wide range of plants, even from plants rich in polysaccharides and polyphenols, high quality RNA can be successfully extracted, such as rice leaves, wheat leaves, corn leaves, tobacco leaves, pine needles, ginkgo leaves, poplar leaves, pomegranate leaves, holly leaves, apples, peaches, pears, tomatoes, cherries, apricots, bananas, grapes, loquats, cinnamon rinds, cinnamon pulp, lychee fruit rinds, lychee pulp, soybean, peanut, corn, potato tuber, moonflower petal, pomegranate petal, shiitake mushroom, flat mushroom and other samples. The unique lysate formula can rapidly inactivate the RNA enzyme in the cell, effectively remove the effect of polysaccharide and polyphenol on RNA extraction, without the need for phenol, chloroform and other reagents, while using silicon matrix membrane adsorption of RNA for purification, the total RNA extracted is highly pure, without the contamination of genomes, proteins and other impurities, and can be used for Real Time RT-PCR, RT-PCR, It can be used for Real Time RT-PCR, RT-PCR, Northern Blot, Dot Blot, in vitro translation and other downstream experiments.RNA yieldSelf-contained reagents: β-mercaptoethanol, anhydrous ethanol (freshly opened or for RNA extraction)Pre-experiment Preparation and Important Notes1. To prevent RNase contamination, attention should be paid to the following aspects:1) Use RNase-free plastics and tips.(2) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.2. Avoid repeated freezing and thawing of the extracted samples, otherwise it will affect the rate and quality of RNA extraction.3. If Buffer RLS produces a precipitate, heat to dissolve it and leave at room temperature.4. Please add β-mercaptoethanol to Buffer RLS before use, add 20µl β-mercaptoethanol to 1ml Buffer RLS. Buffer RLS with β-mercaptoethanol can be stored for 1 month at room temperature.5. Anhydrous ethanol should be added according to the instructions on the reagent bottle label before using Buffer RW2 for the first time. Operation steps1. Homogenization: Take 50-100mg of plant tissue and quickly grind it into powder in liquid nitrogen, add 500µl of Buffer RLS (please check whether β-mercaptoethanol is added before use), and immediately mix it by vortexing with vigorous shaking.Note: For materials that are extremely rich in water content, such as watermelon pulp, tomato, pear pulp, etc., more material can be added appropriately, up to 200 mg; for starch-rich samples or mature leaves, the amount of Buffer RLS can be increased appropriately, up to 700 µl.2. Centrifuge at 12,000 rpm (~13,400 x g) for 2 min at 4°C.3. Transfer the supernatant into the filter columns (Spin Columns FS) that have been loaded into the collection tubes, centrifuge at 12,000 rpm at 4°C for 1 minute, carefully aspirate the supernatant in the collection tubes and transfer it to new RNase-Free centrifugation tubes (self-provided), avoiding the tip of the gun from touching the cell debris precipitation in the collection tubes as much as possible.4. Slowly add 0.5 times the volume of the supernatant in anhydrous ethanol, mix well (a precipitate may appear), and transfer the resulting solution together with the precipitate to a Spin Columns RM in a collection tube, or in two batches if you cannot add all of the solution at once. centrifuge the column for 1 minute at 12,000 rpm at 4°C. Dispose of the spent solution and place the column back into the collection tube. Centrifuge at 12,000 rpm for 1 minute at 4°C, discard the spent solution and return the column to the collection tube.5. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.6. Preparation of DNase I mixture: Take 52µl of RNase-Free Water, add 8µl of 10×Reaction Buffer and 20µl of DNase I (1U/µl) to it, mix well, and prepare a final volume of 80µl of reaction solution.7. Add 80µl of DNase I mixture directly to the adsorption column and incubate at 20-30°C for 15 minutes.8. Add 350 µl of Buffer RW1 to the adsorbent column RM, centrifuge at 12,000 rpm at 4°C for 1 min, discard the waste solution and put the adsorbent column back into the collection tube.9. Add 500 µl of Buffer RW2 to the adsorbent column RM (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 1 minute at 4°C, discard the waste solution and put the adsorbent column back into the collection tube.10. Repeat step 9.11. Centrifuge at 12,000 rpm for 2 minutes at 4°C.Note: The purpose of this step is to remove residual ethanol from the adsorption column; ethanol residue can interfere with subsequent enzymatic reactions (zymography, PCR, etc.).12. Load the adsorption column RM into new RNase-Free Centrifuge Tubes (1.5 ml), add 30-50 µl of RNase-Free Water dropwise to the middle part of the adsorption membrane overhang, leave it at room temperature for 2 min, and centrifuge at 12,000 rpm at 4°C for 1 min, and store the resulting RNA solution at -70°C to prevent degradation.Note: 1) The volume of RNase-Free Water should not be less than 30 µl, too small volume affects the recovery rate.2) If you want to increase the RNA yield, repeat step 12 with 30-50 µl of fresh RNase-Free Water.3) If the RNA concentration is to be increased, the resulting solution can be reintroduced into the adsorption column and step 12 repeated... Read More |