| Description | Inquire | Inquire | Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct Q665720 Component 200T Storage Q665720A Buffer L2 25 mL RT Q665720B Buffer N3 80 mL RT Q665720C Buffer PB 35 mL RT Q665720D Buffer PW (concentrate) 25 mL RT Q665720E Buffer EB 30 mL RT Q665720F RNase A (10 mg/mL) 800 渭L RT Q665720G Spin Columns DM with Collection Tubes 200 EA RTProduct IntroductionThe biggest feature of this kit: simple and fast, high extraction volume. The whole extraction process does not take more than 10 minutes, without centrifugation to collect bacteria and resuspend the bacterium, directly add the unique super lysate Buffer L2 to the cultured bacterial solution, followed by neutralization, centrifugation and passing through the column, and the extracted plasmid can be as high as 30 µg, and maximize the removal of proteins, genomes and other impurities. The extracted plasmid DNA can be directly used for bacterial transformation, digestion, PCR, in vitro transcription, sequencing and other downstream experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. The kit can be stored in a dry, room temperature (15-30°C) environment for 1 year. For longer storage, the centrifuge columns can be placed at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer N3, mix well, and store at 2-8°C.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. If there is any precipitation in Buffer L2 before use, please put it in a 37℃ water bath and keep mixing until the solution becomes clear before use.Operation steps1. Take 600 µl of bacterial culture into a 1.5 ml centrifuge tube (supplied).2. Add 100 µl of Buffer L2 to the above centrifuge tube and gently turn the solution up and down 8 times; the solution should change from turbid to a clear purple color, indicating complete lysis. The cleavage time should not exceed 2 minutes.3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down about 8-10 times, at which point the solution should turn completely yellow and a yellow precipitate should form. centrifuge at 13,000 rpm for 2-3 minutes.4. Slowly pour the supernatant obtained in step 3 into the prepared adsorption columns (Spin Columns DM with Collection Tubes) to avoid sedimentation into the columns.5. Centrifuge at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorption column back into the collection tube.6. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.7. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.8. Place the adsorbent column in a new centrifuge tube (self-provided), add 30-100 µl Buffer EB to the middle part of the adsorbent membrane, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store at -20°C for long term storage.When the amount of extracted bacterial liquid is >600µl, the following procedure can be used:1. This kit can extract up to 3ml of bacterial solution, if the amount of extracted bacterial solution is more than 600µl, it is necessary to centrifuge the bacterial solution exceeding 600µl at 13,000rpm for 30 seconds (to collect the bacterial body), discard the supernatant and then add 600µl of bacterial solution, and then resuspend the bacterial body at the bottom of the tube thoroughly and then proceed to the following operation.2. Add 100µl Buffer L2 to the above centrifuge tube, gently invert the solution up and down 10 times, if the solution is not clarified, need to continue to invert the mixing until the solution becomes a clear purple color, the lysis time should not be more than 2 minutes. (If the solution is still turbid, the amount of bacteria is too large, and the amount of bacteria should be reduced appropriately.)3. Add 350 µl of Buffer N3 to the above centrifuge tube (please check that RNaseA has been added first) and immediately mix well by turning up and down until the purple solution turns completely yellow and a yellow precipitate is formed before proceeding to the next step. centrifuge at 13,000 rpm for 5 minutes.4. Transfer the supernatant to a new centrifuge tube, add 200 µl of isopropanol, mix up and down several times, mix well and transfer to the adsorbent column (Spin Columns DM with Collection Tubes), due to the amount of solution is too large, this time, it is necessary to centrifuge the column in two separate times, centrifugation at 13,000 rpm for 15 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back to the The adsorbent column should be placed back into the collection tube.5. Add 150 µl Buffer PB to the adsorption column and centrifuge at 13,000 rpm for 15 seconds.6. Add 400 µl Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first) and centrifuge at 13,000 rpm for 1 minute.7. Place the adsorbent column in a new centrifuge tube (self-provided), add 50-200 µl Buffer EB to the middle part of the adsorbent membrane, leave it at room temperature for 2 min, centrifuge at 13,000 rpm for 1 min, collect the plasmid DNA, and store it at -20°C for a long time... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |