| Description | Inquire | Inquire | Product content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DFProduct content C665709Component50 TStorageC665709ABuffer CL45 mLRTC665709BBuffer CB (concentrate)60 mLRTC665709CBuffer GW1 (concentrate)13 mLRTC665709DBuffer GW2 (concentrate)15 mLRTC665709EBuffer EBL10 mLRTC665709FProteinase K100 mgRTC665709GProteinase K Storage Buffer5 mLRTC665709HSpin Columns DF with Collection Tubes50 EA2-8℃C665709ICentrifuge Tubes (L-1.5 mL)50 EART Product IntroductionThis kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, lymph fluid and other cell-free body fluids.This kit adopts centrifugal adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. The product can handle liquid samples of 0.1-1 ml, and the elution volume of the configured high-efficiency micro adsorption column can be as low as 20 µl. The purified DNA is of high yield and quality, with maximum removal of proteins, pigments, lipids, and other inhibitors, and the rate of free DNA yield is highly dependent on the type of samples, storage conditions, time, and inter-individual variations. The quality of free DNA obtained from purification is stable and reliable, and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important NotesAdd 5 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it and store it at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time.Repeated freezing and thawing of the sample should be avoided, as this can lead to a decrease in extraction.This kit can extract 0.1-1 ml of liquid samples.Before use, please check Buffer CL, Buffer CB for crystallization or precipitation, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath.Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.Preheat the water bath to 60°C before starting the experiment.The elution buffer Buffer EBL can be preheated to 60°C and used.Operation stepsAdd 20 µl of Proteinase K to the centrifuge tube (supplied).Add 200 µl of serum/plasma sample.Note: When the sample volume exceeds 200 µl, please increase the amount of Proteinase K, Buffer CL and Buffer CB reagents in equal proportions, and the specific amount of reagents added can be referred to the attached table.3. Add 160 µl Buffer CL, mix upside down and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.Note: Incubation of 200µl serum/plasma samples at 60°C for 10-15 minutes is sufficient.Add 360 µl of Buffer CB (check for addition of isopropanol before use) and shake until thoroughly mixed.Ice bath for 5 minutes and centrifuge briefly to concentrate the liquid on the walls and wall caps to the bottom of the tube.Add all of the solution obtained in step 6 to the adsorption columns (Spin Columns DF) that have been loaded into the collection tubes, and if the solution cannot be added all at once, it can be transferred in several times. centrifuge the columns at 12,000 rpm for 1 minute, pour off the waste solution from the collection tubes, and put the columns back into the collection tubes.Add 500µl of Buffer GW1 to the adsorbent column (check that anhydrous ethanol is added before use),centrifuge the column at 12,000rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.Add 750 µl Buffer GW2 to the adsorbent column (check that anhydrous ethanol is added before use), centrifuge at 12,000 rpm for 30 seconds, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.10. Add 750 µl of anhydrous ethanol to the adsorbent column and centrifuge at 12,000 rpm for 30 s. Pour off the waste liquid in the collection tube and put the adsorbent column back into the collection tube.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.12. Place the adsorption column in a new centrifuge tube, add 20-100 µl Buffer EBL or sterilized water to the middle part of the adsorption column overhanging the column, leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH, you can use sterilized water for elution. The pH value of the eluent has a great influence on the elution efficiency, if water is used as the eluent should ensure that its pH value is 7.0-8.5 (you can use NaOH to adjust the pH value of water to this range), and the elution efficiency is not high when the pH value is lower than 7.0.2) Preheat the elution buffer BufferEBL to 60℃ and use it, and incubate it at room temperature for 5 minutes before centrifugation to increase the yield.3) If the final concentration of DNA is to be increased, the resulting solution can be reintroduced into the adsorption column and left at room temperature for 2-5 minutes and centrifuged at 12,000 rpm for 1 minute.4) Because DNA preserved in water will be affected by acidic hydrolysis, for long-term storage, it is recommended to elute it with Buffer EBL and store it at -20℃.Table: Recommended reagent additions for different sample sizes... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |