| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with The perfect KitAlysis Labware starter kit that combines the KitAlysis Inertion Box (Z742064) with the KitAlysis 24-Well Reaction Block and Screwdriver Set (Z742107).Provides an inert environment to run oxygen sensitive cross-coupling reactions in a laboratory fume hood.Designed to be used with KitAlysis High-Throughput Screening Kits.Components:Ιnertion Box24-Well Reaction BlockTorque Screwdriver set with bitReaction Block Replacement Screws (10ea)... Read More | DescriptionThe plasma protein lecithin:cholesterol acyltransferase (LCAT) catalyzes the transfer of an acyl group from the sn2 position of phosphatidylcholine to the 3-hydroxyl group of cholesterol forming cholesteryl ester. This activity occurs on the surface of high density lipoprotein (HDL) and DescriptionThe plasma protein lecithin:cholesterol acyltransferase (LCAT) catalyzes the transfer of an acyl group from the sn2 position of phosphatidylcholine to the 3-hydroxyl group of cholesterol forming cholesteryl ester. This activity occurs on the surface of high density lipoprotein (HDL) and the cholesteryl esters formed by LCAT are incorporated into the core of HDL.Preparation instructionsSuitable for high-throughput screening, mechanism of action studies and structureactivity relationship (SAR) work of LCAT in plasma and serumPrincipleThe LCFC-LCAT Acyltransferase Activity Assay is a fluorometric assay useful for measuring the acyltransferase activity of LCAT in serum or plasma. The method detects changes in LCAT free cholesterol (LCFC) levels in the sample without the use of c... Read More | Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid Product contentN666081Component50 TStorageN666081ANc-Buffer A50 mL2-8℃N666081BNc-Buffer B3 mL2-8℃N666081CNc-Buffer C25 mL2-8℃N666081DProtease Inhibitor Cocktail750 µL-20℃. Avoid freeze/thaw cycle.ProductsThe Nc-Nucleus/Plasma Protein Extraction Kit is a simple and rapid method for extracting nucleus and plasma proteins from mammalian cells and tissues, and the extracted proteins remain biologically active. The kit first cleaves the cell membrane and releases plasma proteins using the plasma protein extraction reagent, and then centrifuges the nucleus to obtain a nucleus precipitate. Finally, the nuclear proteins are extracted by the nuclear protein extraction reagent. The extracted nuclear and plasma proteins are of high purity, effectively avoiding cross-contamination of nuclear and plasma proteins, and can be used for subsequent operations such as Western, Gel Shift, reporter gene detection and enzyme activity determination.Caveat1. If phosphorylated proteins are to be extracted, add a phosphatase inhibitor to the extraction reagent.2. All sample handling should be done on ice.3. The amount of reagents can be adjusted according to the specific experimental situation to ensure that the ratio of each reagent used is Nc-Buffer A:Nc-Buffer B:Nc-Buffer C = 100:5.5:50.4. Higher speeds can be used for centrifugation.ProcedureI Extraction of cytoplasmic and cytosolic proteins from cells1. Please remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.2. Collect the cells and count them. Centrifuge to remove supernatant.3. 1×107 cells were added with 1 ml of Nc-Buffer A (added to Protease Inhibitor Cocktail at a ratio of 1:99 within 2-3 minutes prior to protein pumping), vortexed for 5 seconds to mix well, and incubated on ice for 20 minutes.Note: The characteristics of various cells are different, and the amount of Nc-Buffer A needs to be adjusted according to the characteristics of different cells. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and incubate on ice for 1 minute.5. Centrifuge at 12,000 rpm (~13,400 x g) for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals for about 15-30 seconds each time.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is for cytosolic proteins).II Extraction of cytoplasmic and cytosolic proteins from tissues1. Sampling and preservation of tissues.2. Remove the extraction reagents Nc-Buffer A and Nc-Buffer C for pre-cooling before protein extraction.3. Weigh the tissue and add 1 ml of Nc-Buffer A per 100 mg of tissue (add Protease Inhibitor Cocktail 2-3 minutes before protein extraction at a ratio of 1:99), homogenize well on ice with a homogenizer, and incubate on ice for 20 minutes.Note: The characteristics of various tissues are different, and the amount of Nc-Buffer A needs to be adjusted according to different tissues. If the protein concentration is small, reduce the amount of Nc-Buffer A and subsequent Nc-Buffer B and Nc-Buffer C proportionally.4. Add 55 µl of Nc-Buffer B, vortex for 5 seconds to mix thoroughly, and place on ice for 1 minute of incubation.5. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytoplasmic protein).6. Add 500 µl of Nc-Buffer C (add Protease Inhibitor Cocktail at a ratio of 1:99 before use) to the precipitate obtained in the previous step, vortex for 5 seconds to mix thoroughly, resuspend the precipitate and incubate on ice for 40 minutes, vortexing and mixing at 10-minute intervals at, each time for about 15-30 seconds.7. Centrifuge at 12,000 rpm for 15 minutes at 4°C, collect the supernatant (as clean as possible) into a new centrifuge tube and store at -20°C (this extract is cytosolic protein)... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More |