| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly Product IntroductionBCIP (5-Bromo-4-chloro-3-indolyl phosphate) 5-bromo-4-chloro-3-indolyl-phosphate + NBT (tetrazolium nitro blue) is the best substrate for alkaline phosphatase (AP) One of the combination. Under the catalysis of alkaline phosphatase, BCIP will be hydrolyzed to produce a highly reactive product, which reacts with NBT to form an insoluble dark blue to blue-violet compound. This kit can be used for the enzymatic color development of IHC and Western Blot experiments of the AP system. Under AP catalysis, a dark blue precipitate is produced where AP conjugates are combined on tissue sections or blotting membranes. The location and expression of the target protein can be determined based on the color reaction.Product Components40×BCIP: 1 ml40×NBT: 1 mlBCIP/NBT Buffer: 40 mlPrecautions1. The working fluid should be prepared for immediate use, and the prepared working fluid will be effective within 1 hour.2. The amount of working fluid must be sufficient to ensure complete coverage of the tissue sheet or blotting membrane. To3. In order to obtain the best experimental results, be sure to optimize the experimental conditions.4. NBT is poisonous, please take necessary protective measures when using it.5. This product is only used for scientific research, not for human experiments or human treatment.Instructions1. BCIP/NBT color developing working solution preparation:According to the required amount, mix 40×BCIP, 40×NBT and BCIP/NBT Buffer in a volume ratio of 1:1:38 to form the BCIP/NBT color developing working solution.2. Color rendering:1) Blotting membrane color development: Drop the prepared working solution on the blotting membrane (or pour the blotting membrane into the BCIP/NBT color developing working solution), and incubate for 3-10 minutes at room temperature and dark. After the color development is completed, the film is immersed in water to terminate the reaction.2) Color development of tissue sections or cell slides: Drop an appropriate amount of BCIP/NBT color developing working solution on the tissue sections or cell slides that need color development, and incubate at room temperature for 3-10 minutes in the dark. Observe under the microscope to control the color development time. When the best color development effect is reached, rinse with tap water to stop the color development. After color development, the slices are counter-stained, dehydrated and transparent, and can be stored for a long time after mounting... Read More | Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of Live & deadtm animal cell viability / toxicity detection kit (calcein am, ethd-i) is a kit that provides double fluorescent staining for the detection of animal cell death and survival. The two probes in the kit can respectively measure the activity of cellular lactonase and the integrity of plasma membrane to reflect cell viability. The kit can be used for fluorescence microscopy, flow cytometry, microplate reader and other fluorescence detection systems. This kit can be applied to most eukarYOtic mammalian cells, including some tissues with adherent nuclei, but it is not applicable to fungi and yeast. Compared with trypan blue, the kit is faster, safer and more sensitive.Component: Product parameters:Calcein am: ex/em = 494 / 517 nm; Ethd-i: ex/em = 528 / 617 nm (bound DNA)Usage:Fluorescence microscopy detection1. Prepare working fluidPreparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Remove the original solution of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium, vortex well. The above working solution can be directly used for cell staining.Note: The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. The concentration selection of Calcein AM and EthD-I varies depending on the type of cell used, with a recommended concentration range of 0.1-10 µ M.2. Prepare cells and conduct experiments(1) For adherent cells, they can be washed 2-3 times with 1 × PBS before staining. For suspended cells, centrifuge at room temperature of 250-1000 × g for 5 minutes and collect cells for staining.(2) Wash the cells thoroughly 2-3 times with 1 × PBS to remove residual esterase activity.(3) For adherent cells, add sufficient amount of Calcein AM/EthD-I staining solution. For suspended cells, add an appropriate amount of staining solution to control the cell density between 1-5 × 105/mL.(4) Incubate at room temperature in dark for 15-20 minutes (if the working solution concentration is high or the incubation temperature is high, the incubation time should be appropriately reduced).(5) Observe the labeled cells under a fluorescence microscope.Flow cytometry detection1. Remove the reagent and restore it to room temperature.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution: Take out the original solution of Calcein AM and EthD-I, and restore to room temperature. Add 20 µ L 2 mMEthD-I and 5 µ Vortex mix 4 mM Calcein AM with 10 mL PBS or other serum-free buffer or culture medium. The working fluid can directly stain cells.3. Wash cells thoroughly 2-3 times with 1 × PBS.4. Suspend cells with 0.5 mL of staining solution and control the cell density to 1-5 × 105/mL.Note: It is recommended to prepare two additional cell samples, each containing only one dye (Calcein AM and EthD-I), for compensatory regulation of flow cytometry single staining; Prepare another cell sample containing only buffer solution (which should be consistent with the buffer used to prepare Calcein AM and EthD-I detection working solutions) as a negative control for flow cytometry analysis.5. Incubate at room temperature in dark for 15-20 minutes.6. Within 1-2 hours, cell activity was detected by flow cytometry. Calcein AM can be excited by a 488 nm laser, with fluorescence emission spectra detected at around 530 nm and EthD-I emission spectra at around 610 nm.Note: When using the cell circle gate, attention should be paid to excluding cell debris and using a single staining tube to regulate compensation. Double staining tube flow cytometry should obtain two relatively independent cell populations: a live cell population displaying green fluorescence and a dead cell population displaying red fluorescence.ELISA reader detection1. Cultivate an appropriate amount of adherent or suspended cells in a 96 well black ELISA plate.Note: Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.2. Preparation 2 µ M Calcein AM and 4 µ M EthD-I staining solution:Remove the original solutions of Calcein AM and EthD-I and restore them to room temperature. Add 20 µ L 2 mM EthD-I and 5 µ Mix 4 mM Calcein AM 10 mL PBS or other serum-free buffer or culture medium, vortex well.Note: (1) 10 mL of staining solution is sufficient to stain a 96 well plate, and the volume of the staining solution can be adjusted according to experimental needs. The concentrations of Calcein AM and EthD-I can range from 0.1 to 10 µ Explore between M.(2) The aqueous solution of Calcein AM is easily hydrolyzed and should be used up every day. EthD-I working solution can be stored at -20 ℃ for at least one year.3. Wash the cells thoroughly with 1 × PBS to remove residual esterase activity. For adherent cells, add 100 to each well µ Wash cells with PBS. For suspended cells, add 100 µ Resuspend cells with L PBS and centrifuge to remove the supernatant. Repeat the above operation.4. Add 100 to each hole µ L PBS.5. Add 100 to each hole µ L staining solution, making the total volume of each well 200 µ L. The final concentration of Calcein AM is 1 µ M. The final concentration of EthD-I is 2 µ M. Gently shake the culture plate to evenly cover the cells with the liquid.Incubate at room temperature in dark for 30-45 minutes.Note: The optimal incubation time varies for different cells, with 30 minutes as the initial incubation time. Subsequently, the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect.7. Enzyme reader detection. When the ELISA reader is set to fluorescein, it can detect Calcein AM; When the ELISA reader is set to rhodamine or Texas Red, EthD-I can be detected. Select the optimal emission and excitation wavelengths based on spectral characteristics.Note: By comparing the relative fluorescence values (RFU) measured between the sample group and the control group, the changes in the number of dead and live cells can be obtained. Another method of data analysis is also provided below.The following method can calculate the ratio of live cells to dead cells in a certain region. The required samples include dead cell control group, live cell control group, and the sample group to be tested. Dead cells can be obtained by treating cells with 1% saponin or 0.1-0.5% digitalis saponin for 10 minutes.1. Prepare staining solution and follow the above steps to stain cells. Additionally, prepare 1 mL and 2 mL separately µ M Calcein AM and 4 µ M EthD-I solution, stain the control group according to the following instructions. For the following groups of cells or cell-free groups, it is necessary to maintain complete consistency in cell count, detection of working solution concentration, incubation time, and incubation temperature.2. Measurement of sample group and control group:A. The measured values of the sample group at 645 nm are denoted as Calcein AM and EthD-I=F (645) sam.B. The measured values of the sample group at 530 nm are denoted as Calcein AM and EthD-I=F (530) sam.C. The measurement value of dead cell EthD-I single staining control group at 645 nm is denoted as EthD-I=F (645) maxD. The measurement value of dead cell Calcein AM single staining control group at 645 nm is recorded as Calcein AM=F (645) minE. The measurement value of live cell EthD-I single staining control group at 530 nm is recorded as EthD-I=F (530) min.F. The measurement value of live cell Calcein AM single staining control group at 530 nm is denoted as Calcein AM=F (530) max.G. A blank control well without cells (with or without dye), the detection value at 530 nm is recorded as F (530) 0.H. A blank control well without cells (with or without dye), the detection value at 645 nm is recorded as F (645) 0.3. Calculate the ratio of dead cells to live cells based on measurement data:%Live Cells=(B-E) ÷ (F-E)%Dead Cells=(A-D) ÷ (C-D)Determine the ratio of live cells to dead cells in a certain areaBy creating fluorescence spectral standard curves at 530 nm and 645 nm, the number of dead and live cells can be determined, and the fluorescence intensity of each dye is linearly related to the number of dead or live cells in the sample.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. phenol red or serum may interfere with the detection of this kit. 3. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Dead and live cell staining (animal)... Read More | Product content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kitProduct content: M665794Component125 TStorageM665794A2×miRNA qPCR Mixture (ROX)2×750 µL-20℃. Avoid freeze/thaw cycleM665794BReverse Primer, 10 µM60 µL-20℃. Avoid freeze/thaw cycleM665794CddH2O1.5 mL-20℃. Avoid freeze/thaw cycle Product Introduction:This kit uses the principle of SYBR Green I chimeric fluorescent dye method for miRNA fluorescence quantitative PCR detection. The kit includes 2 x miRNA qPCR Mixture and Reverse Primer required for detection. 2 x miRNA qPCR Mixture is a new generation pre mixed form of fluorescence quantitative PCR detection reagent specially developed for miRNA quantitative detection. The fluorescent dye SYBR Green I contained in it can bind to all double stranded DNA, making the product suitable for detecting different target sequences without the need to synthesize specific labeled probes. The GoldStar Taq DNA polymerase is a chemically modified and highly efficient thermal starter enzyme, coupled with a unique buffer system, which enhances reaction specificity, sensitivity, and enables accurate quantification of miRNA over a wider range. The 2x miRNA qPCR Mixture contains ROX dye and is suitable for fluorescence quantitative PCR instruments that require ROX as a calibration dye.Note: This kit must be used in conjunction with the miRNA cDNA first strand synthesis kit.Self prepared experimental materials: qPCR upstream primer.Forward Primer design principles:1. Follow the most common principles of primer design.2.Based on mature miRNA sequences, replacing U with T is the most basic and simplest design method.3.The Tm value of the downstream primer provided in the reagent kit is 63.6 ℃, and the Tm value of the upstream primer should be designed to be around 63.6 ℃ as much as possible.4. If the Tm value of the primer directly designed according to principle "2" is too low, several bases (preferably G or C bases) can be added to the 5 'end of the primer; One or several A bases can also be added at the 3 'end; Alternatively, both the 5 'and 3' ends can be modified simultaneously.5.If the Tm value of a primer designed directly according to principle "2" is too high, several bases can be removed from the 5 'or 3' end of the primer.Notes:1. Before using the reagent, please gently mix it upside down to avoid foaming, and use it after a brief centrifugation.2. The amount of miRNA first strand cDNA added should not exceed 10% of the volume of Real time PCR.3. For special detection systems, high content of cDNA templates can easily lead to non-specific amplification. Dilute cDNA appropriately (10 or 100 times dilution) based on the abundance of detected miRNAs.4. The 2x miRNA qPCR Mixture in this product contains SYBR Green I and ROX dyes. When storing this product or preparing PCR reaction solution, strong light exposure should be avoided.5. Avoid repeated freezing and thawing of this product. Repeated freezing and thawing may cause a decrease in product performance. This product can be stored at -20 ℃ for long-term storage. If frequent use is required in the short term, the 2xmiRNA qPCR Mixture can be stored at 2-8 ℃. However, the Reverse primer still needs to be stored at -20 ℃.Operation steps:1. Melt 2 x miRNA qPCR Mixture and Reverse Primer at room temperature (10 µ M). 2. When using, please gently mix the 2x miRNA qPCR Mixture upside down to avoid foaming, and use after brief centrifugation. If the reagent is not well mixed, its reaction performance will decrease.3. Place the reagent on ice and prepare the reaction system according to the following table: reagent volume final concentration 2×miRNA qPCR Mixture(ROX) 10 µl 1× Forward primer(10 µM) 0.4µl 0.2 µM Reverse primer(10 µM) 0.4µl 0.2 µM MiRNA first strand cDNA X µl — ddH2O up to 20 µl —4. The reaction program is set as follows:Attention!The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes! Note: 1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) The annealing temperature should be set at 60-64 ℃ as a reference range. When non-specific reactions occur, the annealing temperature can be increased... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |