| Description | ECL Universal Chemiluminescence Kit (Femto-grade) is a non-radioactive chemiluminescence system designed for detecting the activity of horseradish peroxidase (HRP) conjugated to proteins bound on PVDF or NC membranes. This product includes an enhanced luminol substrate and a stable peroxide solutionECL Universal Chemiluminescence Kit (Femto-grade) is a non-radioactive chemiluminescence system designed for detecting the activity of horseradish peroxidase (HRP) conjugated to proteins bound on PVDF or NC membranes. This product includes an enhanced luminol substrate and a stable peroxide solution, enabling the detection of trace amounts of protein as low as the femto-gram level. With a broad detection range and high sensitivity, it is suitable for most conventional Western Blot chemiluminescence detection applications.Component ListE1491293Component100 mL500 mLStorageE1491293AE-ECL Substrate50 mL250 mL2-8℃. Store in the dark.E1491293BE-ECL Oxidant50 mL250 mL2-8℃. Store in the dark. FeaturesHigh Sensitivity – Capable of rapidly detecting proteins at femto-gram levels, outperforming other high-end products in the same category.High Cost-Effectiveness – Offers exceptional value compared to other chemiluminescence substrates of similar grade.Instructions for UseRemove the transfer membrane from the washing buffer and drain excess liquid, ensuring the membrane remains moist.Mix E-ECL Substrate and E-ECL Oxidant in equal volumes to prepare the chemiluminescence working solution (approximately 0.1 mL per square centimeter of membrane).Evenly apply the chemiluminescence working solution onto the membrane and incubate for 1–2 minutes. For highly abundant target proteins, avoid letting the working solution remain stationary. Instead, place the membrane on a shaker for 1–2 minutes to prevent localized depletion of reactants, which may affect the linear range of detection signals.Remove the membrane and drain excess working solution. Wrap the membrane in a transparent protective cover.X-ray Film Exposure: In a darkroom, expose the membrane to X-ray film. Exposure times may range from a few seconds to several minutes. Develop the film and, if necessary, adjust the exposure time for a second exposure based on the initial results.CCD Imager: The membrane can be directly imaged without a protective cover. Follow the instrument’s instructions for imaging.The membrane can be stripped and reused for multiple hybridizations.PrecautionsAvoid strong light exposure to E-ECL Substrate and the working solution, as it may reduce sensitivity.Due to the high sensitivity of the ECL solution, avoid using excessively high antibody concentrations to prevent increased background signals.Sodium azide (NaN₃) inhibits HRP activity. Avoid using NaN₃ for the storage or recycling of secondary antibodies.For safety and health reasons, wear lab coats and disposable gloves during operation.This product is intended for research use only... Read More | DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise.Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 200 nm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to produce multifunctional particles for diverse applications, including dual labelling.For lateral flow tests, magnetic particles are easier to handle than gold. Magnetic separation removes the need to perform centrifugation and filtration concentration. Magnetic particles can provide greater sensitivity than gold during lateral flow tests.Binding Capacity and Polydisperity IndexBinding Capacity: > 50 µg IgG/mgPolydispersity Index (PdI)*: < 0.3* The Polydispersity Index (PdI) is dimensionless and determined using Dynamic Light Scattering (DLS). The PdI is scaled such that values smaller than 0.05 are rarely seen and values greater than 0.7 indicate that the sample has a very broad size distribution and poor monodispersity.Particle based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored at room temperature (15-30℃).Products Content:Products IntroductionThis kit is suitable for the effective purification of genomic DNA and total RNA from paraffin-embedded tissues, using specially optimized deparaffinizing agents and lysates to release DNA and RNA from tissue section samples, without the use of the organic reagent xylene, and without the need for overnight operation; the digested samples are incubated at higher temperatures to remove inhibitors caused by cross-linking, which can effectively improve nucleic acid yields and purity; and an optimized buffer system allows nucleic acids in the lysate to bind specifically to the adsorbent membrane, and inhibitors are effectively removed by a two-step rinsing procedure. The optimized buffer system enables the nucleic acids in the lysate to bind specifically to the adsorbent membrane, and the inhibitors are effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high purity DNA and RNA, and at the same time, equipped with a high-efficiency microsorbent column, the volume of the elution can be as low as 20 µl. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, and so on. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, second-generation sequencing, pharmacogenomics research and blot analysis.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes 1. After obtaining the sample, fix the sample as soon as possible, the fixation time of 14-24 hours is appropriate, too long a period of time will easily lead toDNA and RNA breaks, affecting downstream experiments. If the formaldehyde fixation time is too long or the sample is stored for too long(>1 year) is prone to compromise DNA integrity and failure to amplify long fragments.2. Ensure that samples are thoroughly dehydrated prior to embedding; residual formalin will inhibit Proteinase K action.3. Add 1.25 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it, and store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long period of time to avoid affecting its activity.4. Anhydrous ethanol should be added to Buffer RW2, Buffer GW1 and Buffer GW2 according to the label instructions on the vials before first use.5. Check Buffer GTL, Buffer GL and Buffer DS for crystallization or precipitation prior to use; if crystallization or precipitation occurs, redissolve Buffer GTL, Buffer GL and Buffer DS in a 37°C water bath.6. Preheat the water bath or thermostatic mixer to 56°C before starting the experiment.7. Use an ambient temperature centrifuge or set the centrifuge temperature to 25°C. Temperatures below 15°C may result in clogging of the adsorption column.8. To prevent RNase contamination, the following should be observed:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry baked at 180°C for 4 hours before use, plasticware can be soaked in 0.5 M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.procedureParaffin-embedded samples1. Trim off excess paraffin from the tissue block to expose the tissue and cut into 5-10 µm slices.2. Place approximately 1 x 1 cm2 slices (1-5 slices in total) in a centrifuge tube (supplied), add 500 µl of Buffer DS and vortex for 10 s. Briefly centrifuge the sample to the bottom of the tube. Centrifuge briefly to collect the sample at the bottom of the tube, incubate at 56°C for 3 minutes, remove from the water bath and allow to cool to room temperature before proceeding.Note: If the surface of the sample is exposed to air, discard the initial 2-3 slices without using them.3. Centrifuge at 12,000 rpm for 2 minutes and carefully discard the supernatant thoroughly without aspirating the precipitate. The residual dewaxing solution can be carefully removed with a small tip (10 µl).4. Add 180 µl of Buffer GTL and 20 µl of Proteinase K to the above tube and mix well with vortexing.5. Incubate at 56°C for 15 minutes, then place on ice for 3 minutes. Centrifuge at 12,000 rpm for 15 minutes at room temperature.6. Transfer the supernatant to a new 1.5 ml centrifuge tube for RNA extraction, taking care not to aspirate undigested tissue. Use the precipitate for DNA extraction. RNA extraction7. Take the supernatant obtained in step 6 and incubate at 80°C for 15 minutes.8. Add 320 µl of Buffer GL, mix by vortexing and shaking, then add 720 µl of anhydrous ethanol and mix immediately by vortexing and shaking.9. Add all of the resulting solution to the Spin Columns RS in the collection tube; if the solution cannot be added all at once, it may be transferred in several passes. centrifuge the column at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and place the column back into the collection tube. Note: If the columns are clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.Optional step: If genomic DNA is to be removed, the following steps can be followeda. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and place the column back into the collection tube.b. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water and add 8 µl of 10×Reaction to it.Buffer and 20 µl DNase I (1 U/µl), mix well, and prepare a final volume of 80 µl of reaction solution.c. Add 80 µl of DNase I Mix directly to the adsorption column and incubate at 20-30°C for 15 minutes.d. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.Add 500 µl of Buffer RW2 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.11. Repeat step 10. centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the column at room temperature for 5 minutes.minutes to dry thoroughly.12. Place the column in a new RNase-free centrifuge tube and add 20-50 µl to the center of the column.RNase-Free Water, left at room temperature for 5 minutes, centrifuged at 12,000 rpm for 1 minute, and collected RNA solution, the-80°C for storage.DNA extraction7. Take the precipitate obtained in step 6 and add 180 µl Buffer GTL and 20 µl Proteinase K to the precipitate. VortexResuspend the precipitate for 15 seconds.8. Incubate at 56°C for 1 hour until the sample is completely dissolved. 90°C for 1 hour.Add 200 µl Buffer GL, vortex and shake to mix and then add 200 µl anhydrous ethanol, vortex and shake to mix thoroughly. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube. Add all of the solution from step 9 to the Spin Columns DF in the collection tube, or transfer the solution in several passes. centrifuge at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and return the column to the 10. collection tube.Note: If the adsorption column is clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.11. Add 500 µl of Buffer GW1 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and put the column back into the collection tube.12. Add 500 µl of Buffer GW2 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and place the column back into the collection tube.Note: Step 12 may be repeated if further purity is required.13. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for 5 minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue will affect the subsequent enzymatic reaction. 14. Place the column in a new 1.5 ml centrifuge tube, add 20-50 µl Buffer EB to the center of the column, leave at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |