| Description | Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances luminescent signal intensity, effectively improving detection sensitivity. It can be used to detect firefly luciferase reporter gene expression in ADCC Reporter Bioassays or cells. G1375755Component10 mL100 mLStorageG1375755AFirefly Luciferase Reaction Buffer (Glow)10 mL100 mL-20℃. Store in the dark.G1375755BFirefly Luciferase Substrate (Glow)1 vial1 vial-20℃. Store in the dark.he main features and differences among three One-Step Firefly Luciferase Reporter Gene Assay Kits from Aladdin are as follows:For high luminescent signal requirements and detection within 30 minutes: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760)For both luminescent signal and stability requirements, suitable for batch or continuous operation: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Cat. No. F773892)For standard luminescent signal requirements: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow) (Cat. No. G1375755)For routine laboratory detection, the Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760) is the recommended priority. Product Cat. No.Product NameLuminescence TypeSignal IntensitySensitivityHalf-LifePackagingSuitable for Batch SamplesOptimal Use After Mixing & Storing at -20°CF773892Firefly Luciferase Reporter Gene Assay KitGlowRelatively HighRelatively SensitiveUp to 2h1 bottle Buffer1 vial SubstrateVery Suitable1 MonthG1375755Firefly Luciferase Reporter Gene Assay Kit (Glow)GlowHighSensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekB1375760Firefly Luciferase Reporter Gene Assay Kit (Glow Bright)GlowVery HighHighly Sensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekInstructions for Use:1. User-Supplied MaterialsPBSMultichannel pipetteWhite or black opaque cell culture microplateLuminometer or microplate reader equipped with a luminescence detection module.2. Preparation Before Assay(1) Initial Reconstitution: Upon first use, transfer the entire contents of the Firefly Luciferase Reaction Buffer (Glow) bottle into the Firefly Luciferase Substrate (Glow) vial. Mix thoroughly until the substrate is completely dissolved. Aliquot the reconstituted detection reagent as needed. For long-term storage, aliquot and store at -70°C. For short-term storage, store aliquots at -20°C for no longer than one month. Use reconstituted reagent promptly.(2) Pre-assay: Before each experiment, equilibrate the aliquoted, frozen detection reagent to room temperature.3. Procedure(1) Equilibrate Plates: Remove the cell culture plate from the incubator and allow it to stand at room temperature for 5-15 minutes.Note: Use white or black opaque cell culture plates to minimize signal interference between wells.(2) Add Detection Reagent: Using a multichannel pipette, add the equilibrated Firefly Luciferase Reaction Buffer (Glow) containing the substrate to each cell culture well. The volume added should be equal to the volume of the culture medium in the well. For example:* 96-well plate: Typically add 80-100 µL culture medium; add 80-100 µL detection reagent.* 384-well plate: Typically add 20-30 µL culture medium; add 20-30 µL detection reagent.(3) Mix to Lyse Cells: To ensure complete cell lysis, place the plate on an orbital shaker or an instrument with shaking capability. Shake at medium to high speed at room temperature for 5 minutes.Note: A shaking time of 5 minutes is recommended. This can be adjusted based on cell density to ensure complete lysis and stable luminescent results.(4) Detection: Following the shaking step, immediately measure firefly luciferase reporter gene activity using a luminometer or microplate reader.Note: For optimal results, perform the detection as soon as possible after adding the detection reagent.PrecautionsInstrument Selection: Any instrument capable of detecting chemiluminescence is suitable for use with this kit. However, background signal levels and measured values for identical samples may vary between different detectors. Values obtained from different instruments for the same sample are not directly comparable. To prevent well-to-well interference, the use of opaque white or black cell culture plates is strongly recommended.Consistent Conditions: Luminescent signals can be influenced by environmental factors such as medium components and temperature. Ensure consistent detection conditions across all samples within an experiment.Temperature Sensitivity: The enzymatic reaction is temperature-sensitive. It is essential to equilibrate both the detection reagent and the cell culture plate to room temperature before adding the reagent and performing the assay.Reagent Stability: To maintain the stability of the luciferase assay reagent, aliquot it appropriately after reconstitution. For long-term storage, store aliquots at -70°C protected from light. For short-term storage, store at -20°C for no longer than one month. Use aliquots promptly and avoid repeated freeze-thaw cycles.Multiple Plate Assay: If detecting multiple cell culture plates simultaneously, strive to maintain consistent incubation time after adding the detection reagent to each plate before reading. This ensures optimal and comparable results across plates.Emission Wavelength: The bioluminescence catalyzed by firefly luciferase exhibits a peak emission wavelength of 560 nm... Read More | Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products Content:F666101Component500 U5000 UStorageF666101AFastStar Probe Buffer (for bisDNA)2×1.2 mL2×12 mL-20℃. Avoid freeze/thaw cycle. Protect from light.F666101BSuperFastStar DNA Polymerase (5U/µL)100 µL1 mL-20℃. Avoid freeze/thaw cycle. Protect from light.Products IntroductionThis product is mainly used for PCR using bisulfite-treated DNA as template, in which SuperFastStar DNA Polymerase is a new high-efficiency hot-start enzyme modified by bis-monoclonal antibody, which is completely blocked at room temperature, thus effectively avoiding non-specific amplification caused by the non-specific binding of the primer to the template or the primer dimerization under the condition of room temperature. The optimized FastStar Probe Buffer (for bisDNA) contains PCR Buffer, dNTPs and Mg2+, etc., which is easy to use as customers only need to add templates, primers and probes.caveat1 Before use, please mix the product gently by turning it up and down after it has been completely melted and centrifuged briefly.2. Avoid repeated freezing and thawing of the product, which may degrade its performance. This product can be stored at -20℃ for a long period of time, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.Usage The following examples are conventional PCR reaction systems and conditions, which should be improved and optimized according to the template, primer structure and target fragment size.1.PCR reaction system Note: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.2)The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3)Usually the amount of DNA template is 10-100 ng of genomic DNA or 1-10 ng of cDNA as a reference. Since the templates of different species contain different copy numbers of the target gene, the templates can be diluted in gradients to determine the optimal amount of template to use.2.PCR reaction conditionsNote: 1) The initial denaturation of this product at 95°C for 30s is sufficient for enzyme activation; complex templates can be extended to 3min denaturation.(2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try three-step PCR amplification, and the annealing temperature should be set in the range of 56℃-64℃ as a reference... Read More | Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the transposase-based second-generation sequencing Rapid DNA Library Construction Kit, designed for Illumina platform library construction, which contains 8 primers at the N5 end and 12 primers at the N7 end, which can be used to prepare 96 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The prepared libraries can be sequenced on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes; tips: It is recommended to use high-quality filtration tips to prevent contamination of reagent kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501-N508 Primers for IlluminaIndex N701-N712 Primers for Illumina... Read More | Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for Product content: Component S665549 50 preps Buffer SW 60 ml Buffer SL 60 ml Buffer GL 50 ml Buffer GW1(concentrate) 2X13 ml Buffer GW2(concentrate) 15 ml Buffer GE 15 ml Spin Columns DM 50 with Collection Tubes 50Product IntroductionThis kit is suitable for extracting total DNA from fecal samples, including the total DNA of cells, bacteria, parasites, and viruses in the samples, as well as samples containing high concentrations of PCR reaction inhibitors. This product can process up to 300 mg of fecal samples and purify to obtain mainly 20-30 kb DNA fragments. The purification process does not require toxic solvents such as phenol or chloroform, and does not require ethanol precipitation. High purity DNA can be obtained within one hour. This reagent kit adopts a unique buffering system to efficiently bind DNA from the lysis solution to the adsorption column. At the same time, protein impurities and other organic compounds that inhibit downstream reactions in feces can flow through the membrane. Inhibitors of PCR and enzyme reactions, as well as residual impurities, can be effectively removed through two washing steps. Finally, high-purity DNA can be obtained by washing with low salt buffer or water. The purified DNA can be directly used for downstream experiments such as enzyme digestion, PCR, Real Time PCR, library construction, Southern Blot, and molecular labeling.Preparation and important precautions before the experiment1. Samples should avoid repeated freeze-thaw cycles, otherwise it may result in smaller extracted DNA fragments and a decrease in extraction volume.2.Before the first use, anhydrous ethanol should be added to Buffer GW1 and GW2 according to the instructions on the reagent bottle label.3. Before use, please check whether there is crystallization or precipitation in Buffer SL and Buffer GL. If there is crystallization or precipitation, please dissolve Buffer SL and Buffer GL again in a 56 ℃ water bath.4. If downstream experiments are sensitive to RNA contamination, 4 can be added after adding Buffer SL µ RNase A of DNase Free (100 mg/ml) is not provided in this kit. If needed, it can be ordered separately from our company, item number: S665549Operation steps1. Take a fecal sample of 100-300 mg and place it in a centrifuge tube (provided by oneself).2. Add 1 ml of Buffer SW and vortex for 3-5 minutes to evenly disperse the sample in the solution. Centrifuge at 12000 rpm (~13400 × g) for 1 minute and discard the supernatant.3. Add 1 ml of Buffer SL and vortex for 3-5 minutes to evenly disperse the sample in the solution. Take a water bath at 65 ℃ for 20 minutes and vortex for 15 seconds every 5 minutes. Note: To remove RNA, add 4 after completing the above steps µ RNase A solution (product number: CW0601S) with a concentration of 100 mg/ml, shake well and let stand at room temperature for 5-10 minutes.4.Centrifuge at 2000 rpm for 3 minutes and transfer the supernatant to a new centrifuge tube (provided by oneself).5. Add an equal volume of Buffer GL to the supernatant, invert and mix 15-25 times, and leave on ice for 5 minutes. Centrifuge at 12000 rpm for 5 minutes. Attention: At this time, the liquid may be in a transparent or turbid state, which does not affect the experiment. 6. Add the supernatant obtained in step 5 to the spin columns DM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Buffer GW1 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. 8. Repeat step 7.9. Add 500 to the adsorption column µ Buffer GW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new centrifuge tube (self provided) and add 50-100 drops of suspended droplets to the middle of the adsorption column µ L Buffer GE or sterilized water, leave at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect DNA solution, and store DNA at -20 ℃.Note: 1) If downstream experiments are sensitive to pH or EDTA, they can be washed off with sterilized water. The pH value of the eluent has a significant impact on the elution efficiency. If water is used as the eluent, its pH value should be ensured to be between 7.0-8.5 (NaOH can be used to adjust the pH value of the water to this range). When the pH value is below 7.0, the elution efficiency will be reduced2) Incubating at room temperature for 5 minutes before centrifugation can increase yield.3) Use an additional 50-100 µ Further washing with buffer GE or sterilized water can increase yield.4) If you want to increase the final concentration of DNA, you can add the DNA eluent obtained in step 11 back onto the adsorption membrane and repeat step 11; It is possible to increase the final concentration of DNA, but it may reduce the total yield. If the amount of DNA is less than 1 µ g. Recommended 50 µ Wash with buffer GE or sterilized water.5) DNA stored in water can be affected by acidic hydrolysis. If long-term storage is required, it is recommended to elute with Buffer GE and store at -20 ℃.6) The residual trace PCR inhibitors in the genomic DNA template may have adverse effects on the PCR reaction, which can be solved by diluting DNA by 2-10 times... Read More | Inquire |