| Description | Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances luminescent signal intensity, effectively improving detection sensitivity. It can be used to detect firefly luciferase reporter gene expression in ADCC Reporter Bioassays or cells. G1375755Component10 mL100 mLStorageG1375755AFirefly Luciferase Reaction Buffer (Glow)10 mL100 mL-20℃. Store in the dark.G1375755BFirefly Luciferase Substrate (Glow)1 vial1 vial-20℃. Store in the dark.he main features and differences among three One-Step Firefly Luciferase Reporter Gene Assay Kits from Aladdin are as follows:For high luminescent signal requirements and detection within 30 minutes: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760)For both luminescent signal and stability requirements, suitable for batch or continuous operation: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Cat. No. F773892)For standard luminescent signal requirements: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow) (Cat. No. G1375755)For routine laboratory detection, the Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760) is the recommended priority. Product Cat. No.Product NameLuminescence TypeSignal IntensitySensitivityHalf-LifePackagingSuitable for Batch SamplesOptimal Use After Mixing & Storing at -20°CF773892Firefly Luciferase Reporter Gene Assay KitGlowRelatively HighRelatively SensitiveUp to 2h1 bottle Buffer1 vial SubstrateVery Suitable1 MonthG1375755Firefly Luciferase Reporter Gene Assay Kit (Glow)GlowHighSensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekB1375760Firefly Luciferase Reporter Gene Assay Kit (Glow Bright)GlowVery HighHighly Sensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekInstructions for Use:1. User-Supplied MaterialsPBSMultichannel pipetteWhite or black opaque cell culture microplateLuminometer or microplate reader equipped with a luminescence detection module.2. Preparation Before Assay(1) Initial Reconstitution: Upon first use, transfer the entire contents of the Firefly Luciferase Reaction Buffer (Glow) bottle into the Firefly Luciferase Substrate (Glow) vial. Mix thoroughly until the substrate is completely dissolved. Aliquot the reconstituted detection reagent as needed. For long-term storage, aliquot and store at -70°C. For short-term storage, store aliquots at -20°C for no longer than one month. Use reconstituted reagent promptly.(2) Pre-assay: Before each experiment, equilibrate the aliquoted, frozen detection reagent to room temperature.3. Procedure(1) Equilibrate Plates: Remove the cell culture plate from the incubator and allow it to stand at room temperature for 5-15 minutes.Note: Use white or black opaque cell culture plates to minimize signal interference between wells.(2) Add Detection Reagent: Using a multichannel pipette, add the equilibrated Firefly Luciferase Reaction Buffer (Glow) containing the substrate to each cell culture well. The volume added should be equal to the volume of the culture medium in the well. For example:* 96-well plate: Typically add 80-100 µL culture medium; add 80-100 µL detection reagent.* 384-well plate: Typically add 20-30 µL culture medium; add 20-30 µL detection reagent.(3) Mix to Lyse Cells: To ensure complete cell lysis, place the plate on an orbital shaker or an instrument with shaking capability. Shake at medium to high speed at room temperature for 5 minutes.Note: A shaking time of 5 minutes is recommended. This can be adjusted based on cell density to ensure complete lysis and stable luminescent results.(4) Detection: Following the shaking step, immediately measure firefly luciferase reporter gene activity using a luminometer or microplate reader.Note: For optimal results, perform the detection as soon as possible after adding the detection reagent.PrecautionsInstrument Selection: Any instrument capable of detecting chemiluminescence is suitable for use with this kit. However, background signal levels and measured values for identical samples may vary between different detectors. Values obtained from different instruments for the same sample are not directly comparable. To prevent well-to-well interference, the use of opaque white or black cell culture plates is strongly recommended.Consistent Conditions: Luminescent signals can be influenced by environmental factors such as medium components and temperature. Ensure consistent detection conditions across all samples within an experiment.Temperature Sensitivity: The enzymatic reaction is temperature-sensitive. It is essential to equilibrate both the detection reagent and the cell culture plate to room temperature before adding the reagent and performing the assay.Reagent Stability: To maintain the stability of the luciferase assay reagent, aliquot it appropriately after reconstitution. For long-term storage, store aliquots at -70°C protected from light. For short-term storage, store at -20°C for no longer than one month. Use aliquots promptly and avoid repeated freeze-thaw cycles.Multiple Plate Assay: If detecting multiple cell culture plates simultaneously, strive to maintain consistent incubation time after adding the detection reagent to each plate before reading. This ensures optimal and comparable results across plates.Emission Wavelength: The bioluminescence catalyzed by firefly luciferase exhibits a peak emission wavelength of 560 nm... Read More | DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the DescriptionThe 200 nm Coupling Kit makes conducting lateral flow tests and biomolecule separation (including cell separation) easier and more flexible. The Kit contains AnteoBind™activated 200 nm magnetic particles that give you increased antibody binding capacity and functionality, while the included blocking buffer decreases background noise.Reduce reagent preparation time; remove traditional surface preparation steps such as EDC and replace these steps with the 200 nm pre-activated magnetic particles provided. This Kit reduces aggregation and gives you the freedom and ability to produce multifunctional particles for diverse applications, including dual labelling.For lateral flow tests, magnetic particles are easier to handle than gold. Magnetic separation removes the need to perform centrifugation and filtration concentration. Magnetic particles can provide greater sensitivity than gold during lateral flow tests.Binding Capacity and Polydisperity IndexBinding Capacity: > 50 µg IgG/mgPolydispersity Index (PdI)*: < 0.3* The Polydispersity Index (PdI) is dimensionless and determined using Dynamic Light Scattering (DLS). The PdI is scaled such that values smaller than 0.05 are rarely seen and values greater than 0.7 indicate that the sample has a very broad size distribution and poor monodispersity.Particle based Immunoassays, Lateral Flow, Bioseparations and Immunoprecipitation... Read More | Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize Product Characteristics Effect Diluents, Animal-free are effective buffers free of any animal components. They can be used for the dilution of serum, plasma, blood, stool or urine samples, as well as the dilution of primary and secondary antibodies. Effect Diluents, Animal-free efficiently minimize matrix effects, cross-reactions and unspecific binding in immunoassays like ELISA, Western blotting, Immunohistochemistry, protein arrays and immuno-PCR.The Effect Diluents, Animal-free are used alternatively to the standard sample or antibody dilution buffers: In ELISA for the dilution of specimen and detection antibodies. In Western Blotting for the dilution of primary and secondary antibodies. In Protein arrays for the dilution of specimen and detection antibodies. In immuno-PCR as a washing buffer.Three versions of the diluent are offered: Low, Medium and High for optimal discrimination between specific and unspecific reaction and for minimizing strong interference effects e.g., by RF (rheumatoid factors), HAMAs (human-a-mouse Abs) or by endogenous components that bind and mask the analyte.Composition & Properties The Effect Diluents, Animal free contain no animal components and are free of phosphates.Working Procedure 1.Mix thoroughly prior to use. 2.Dilution recommendations a.Dilute antibodies according to the instruction of the antibody b.Dilution of the specimen is recommended at 1:2 or higherTips & TricksEffect Diluents must not be considered as blocking buffers. Recommended blocking buffers are: Synthetic Blocking Buffer, ELISA (cat. no. S494401), Synthetic Blocking Buffer, Blotting (cat. no. S494457) and WellChampion (cat. no. W494467) for plate blocking and stabilization (preparation of pre-coated plates). Complex sample matrices, such as serum and plasma, may contain interfering factors that affect the ability of the assay to accurately quantify the target analyte. Strong interferences are often caused by RFs and HAMAs. This matrix effect can cause high background in the negative control or false negatives in the sample measurement. To reduce this effect the samples can be diluted in the Effect Diluents, Animalfree.Handling & Storage Store solution 2-8°C or -15 to -30°C (tolerates freezing and thawing cycles)... Read More | FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored FFPE DNA/RNA KitFixed Tissue DNA/RNA Extraction Kit Catalog number: F666120 (50 preps)Storage conditions: DNase I and 10×Reaction Buffer -20℃, Spin Columns DF and Spin Columns RS can be stored at room temperature for 2 months, 2-8℃ for 1 year, the rest of the components are stored at room temperature (15-30℃).Products Content:Products IntroductionThis kit is suitable for the effective purification of genomic DNA and total RNA from paraffin-embedded tissues, using specially optimized deparaffinizing agents and lysates to release DNA and RNA from tissue section samples, without the use of the organic reagent xylene, and without the need for overnight operation; the digested samples are incubated at higher temperatures to remove inhibitors caused by cross-linking, which can effectively improve nucleic acid yields and purity; and an optimized buffer system allows nucleic acids in the lysate to bind specifically to the adsorbent membrane, and inhibitors are effectively removed by a two-step rinsing procedure. The optimized buffer system enables the nucleic acids in the lysate to bind specifically to the adsorbent membrane, and the inhibitors are effectively removed by a two-step rinsing step, and finally eluted with low-salt buffer or water to obtain high purity DNA and RNA, and at the same time, equipped with a high-efficiency microsorbent column, the volume of the elution can be as low as 20 µl. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, and so on. The purified DNA and RNA can be directly used for PCR, Real-time PCR, SNP genotyping, STR genotyping, second-generation sequencing, pharmacogenomics research and blot analysis.Self-contained reagent: anhydrous ethanolPre-experiment Preparation and Important Notes 1. After obtaining the sample, fix the sample as soon as possible, the fixation time of 14-24 hours is appropriate, too long a period of time will easily lead toDNA and RNA breaks, affecting downstream experiments. If the formaldehyde fixation time is too long or the sample is stored for too long(>1 year) is prone to compromise DNA integrity and failure to amplify long fragments.2. Ensure that samples are thoroughly dehydrated prior to embedding; residual formalin will inhibit Proteinase K action.3. Add 1.25 ml of Proteinase K Storage Buffer to Proteinase K to dissolve it, and store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long period of time to avoid affecting its activity.4. Anhydrous ethanol should be added to Buffer RW2, Buffer GW1 and Buffer GW2 according to the label instructions on the vials before first use.5. Check Buffer GTL, Buffer GL and Buffer DS for crystallization or precipitation prior to use; if crystallization or precipitation occurs, redissolve Buffer GTL, Buffer GL and Buffer DS in a 37°C water bath.6. Preheat the water bath or thermostatic mixer to 56°C before starting the experiment.7. Use an ambient temperature centrifuge or set the centrifuge temperature to 25°C. Temperatures below 15°C may result in clogging of the adsorption column.8. To prevent RNase contamination, the following should be observed:1) Use RNase-free plastics and tips to avoid cross-contamination.(2) Glassware should be dry baked at 180°C for 4 hours before use, plasticware can be soaked in 0.5 M NaOH for 10 minutes, rinsed thoroughly with water and autoclaved.3) RNase-free water should be used to prepare the solution.(4) Operators wear disposable masks and gloves, and change gloves diligently during the experiment.procedureParaffin-embedded samples1. Trim off excess paraffin from the tissue block to expose the tissue and cut into 5-10 µm slices.2. Place approximately 1 x 1 cm2 slices (1-5 slices in total) in a centrifuge tube (supplied), add 500 µl of Buffer DS and vortex for 10 s. Briefly centrifuge the sample to the bottom of the tube. Centrifuge briefly to collect the sample at the bottom of the tube, incubate at 56°C for 3 minutes, remove from the water bath and allow to cool to room temperature before proceeding.Note: If the surface of the sample is exposed to air, discard the initial 2-3 slices without using them.3. Centrifuge at 12,000 rpm for 2 minutes and carefully discard the supernatant thoroughly without aspirating the precipitate. The residual dewaxing solution can be carefully removed with a small tip (10 µl).4. Add 180 µl of Buffer GTL and 20 µl of Proteinase K to the above tube and mix well with vortexing.5. Incubate at 56°C for 15 minutes, then place on ice for 3 minutes. Centrifuge at 12,000 rpm for 15 minutes at room temperature.6. Transfer the supernatant to a new 1.5 ml centrifuge tube for RNA extraction, taking care not to aspirate undigested tissue. Use the precipitate for DNA extraction. RNA extraction7. Take the supernatant obtained in step 6 and incubate at 80°C for 15 minutes.8. Add 320 µl of Buffer GL, mix by vortexing and shaking, then add 720 µl of anhydrous ethanol and mix immediately by vortexing and shaking.9. Add all of the resulting solution to the Spin Columns RS in the collection tube; if the solution cannot be added all at once, it may be transferred in several passes. centrifuge the column at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and place the column back into the collection tube. Note: If the columns are clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.Optional step: If genomic DNA is to be removed, the following steps can be followeda. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and place the column back into the collection tube.b. Preparation of DNase I mixture: Take 52 µl of RNase-Free Water and add 8 µl of 10×Reaction to it.Buffer and 20 µl DNase I (1 U/µl), mix well, and prepare a final volume of 80 µl of reaction solution.c. Add 80 µl of DNase I Mix directly to the adsorption column and incubate at 20-30°C for 15 minutes.d. Add 350 µl of Buffer RW1 to the column, centrifuge at 12,000 rpm for 1 minute, discard the waste solution, and return the column to the collection tube.Add 500 µl of Buffer RW2 to the adsorbent column, centrifuge at 12,000 rpm for 1 min, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.11. Repeat step 10. centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Place the column at room temperature for 5 minutes.minutes to dry thoroughly.12. Place the column in a new RNase-free centrifuge tube and add 20-50 µl to the center of the column.RNase-Free Water, left at room temperature for 5 minutes, centrifuged at 12,000 rpm for 1 minute, and collected RNA solution, the-80°C for storage.DNA extraction7. Take the precipitate obtained in step 6 and add 180 µl Buffer GTL and 20 µl Proteinase K to the precipitate. VortexResuspend the precipitate for 15 seconds.8. Incubate at 56°C for 1 hour until the sample is completely dissolved. 90°C for 1 hour.Add 200 µl Buffer GL, vortex and shake to mix and then add 200 µl anhydrous ethanol, vortex and shake to mix thoroughly. Centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube. Add all of the solution from step 9 to the Spin Columns DF in the collection tube, or transfer the solution in several passes. centrifuge at 12,000 rpm for 1 minute, pour off the waste solution from the collection tube, and return the column to the 10. collection tube.Note: If the adsorption column is clogged, the sample size may be too large and consideration should be given to reducing the number of starting sections to 1-2.11. Add 500 µl of Buffer GW1 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and put the column back into the collection tube.12. Add 500 µl of Buffer GW2 to the adsorbent column and centrifuge at 12,000 rpm for 1 minute. Pour off the waste liquid from the collection tube and place the column back into the collection tube.Note: Step 12 may be repeated if further purity is required.13. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for 5 minutes to dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorbent column; ethanol residue will affect the subsequent enzymatic reaction. 14. Place the column in a new 1.5 ml centrifuge tube, add 20-50 µl Buffer EB to the center of the column, leave at room temperature for 5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃... Read More | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |