| Description | Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances luminescent signal intensity, effectively improving detection sensitivity. It can be used to detect firefly luciferase reporter gene expression in ADCC Reporter Bioassays or cells. G1375755Component10 mL100 mLStorageG1375755AFirefly Luciferase Reaction Buffer (Glow)10 mL100 mL-20℃. Store in the dark.G1375755BFirefly Luciferase Substrate (Glow)1 vial1 vial-20℃. Store in the dark.he main features and differences among three One-Step Firefly Luciferase Reporter Gene Assay Kits from Aladdin are as follows:For high luminescent signal requirements and detection within 30 minutes: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760)For both luminescent signal and stability requirements, suitable for batch or continuous operation: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Cat. No. F773892)For standard luminescent signal requirements: Recommended: Firefly Luciferase Reporter Gene Assay Kit (Glow) (Cat. No. G1375755)For routine laboratory detection, the Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760) is the recommended priority. Product Cat. No.Product NameLuminescence TypeSignal IntensitySensitivityHalf-LifePackagingSuitable for Batch SamplesOptimal Use After Mixing & Storing at -20°CF773892Firefly Luciferase Reporter Gene Assay KitGlowRelatively HighRelatively SensitiveUp to 2h1 bottle Buffer1 vial SubstrateVery Suitable1 MonthG1375755Firefly Luciferase Reporter Gene Assay Kit (Glow)GlowHighSensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekB1375760Firefly Luciferase Reporter Gene Assay Kit (Glow Bright)GlowVery HighHighly Sensitive25-30min1 bottle Buffer1 vial SubstrateVery Suitable1 WeekInstructions for Use:1. User-Supplied MaterialsPBSMultichannel pipetteWhite or black opaque cell culture microplateLuminometer or microplate reader equipped with a luminescence detection module.2. Preparation Before Assay(1) Initial Reconstitution: Upon first use, transfer the entire contents of the Firefly Luciferase Reaction Buffer (Glow) bottle into the Firefly Luciferase Substrate (Glow) vial. Mix thoroughly until the substrate is completely dissolved. Aliquot the reconstituted detection reagent as needed. For long-term storage, aliquot and store at -70°C. For short-term storage, store aliquots at -20°C for no longer than one month. Use reconstituted reagent promptly.(2) Pre-assay: Before each experiment, equilibrate the aliquoted, frozen detection reagent to room temperature.3. Procedure(1) Equilibrate Plates: Remove the cell culture plate from the incubator and allow it to stand at room temperature for 5-15 minutes.Note: Use white or black opaque cell culture plates to minimize signal interference between wells.(2) Add Detection Reagent: Using a multichannel pipette, add the equilibrated Firefly Luciferase Reaction Buffer (Glow) containing the substrate to each cell culture well. The volume added should be equal to the volume of the culture medium in the well. For example:* 96-well plate: Typically add 80-100 µL culture medium; add 80-100 µL detection reagent.* 384-well plate: Typically add 20-30 µL culture medium; add 20-30 µL detection reagent.(3) Mix to Lyse Cells: To ensure complete cell lysis, place the plate on an orbital shaker or an instrument with shaking capability. Shake at medium to high speed at room temperature for 5 minutes.Note: A shaking time of 5 minutes is recommended. This can be adjusted based on cell density to ensure complete lysis and stable luminescent results.(4) Detection: Following the shaking step, immediately measure firefly luciferase reporter gene activity using a luminometer or microplate reader.Note: For optimal results, perform the detection as soon as possible after adding the detection reagent.PrecautionsInstrument Selection: Any instrument capable of detecting chemiluminescence is suitable for use with this kit. However, background signal levels and measured values for identical samples may vary between different detectors. Values obtained from different instruments for the same sample are not directly comparable. To prevent well-to-well interference, the use of opaque white or black cell culture plates is strongly recommended.Consistent Conditions: Luminescent signals can be influenced by environmental factors such as medium components and temperature. Ensure consistent detection conditions across all samples within an experiment.Temperature Sensitivity: The enzymatic reaction is temperature-sensitive. It is essential to equilibrate both the detection reagent and the cell culture plate to room temperature before adding the reagent and performing the assay.Reagent Stability: To maintain the stability of the luciferase assay reagent, aliquot it appropriately after reconstitution. For long-term storage, store aliquots at -70°C protected from light. For short-term storage, store at -20°C for no longer than one month. Use aliquots promptly and avoid repeated freeze-thaw cycles.Multiple Plate Assay: If detecting multiple cell culture plates simultaneously, strive to maintain consistent incubation time after adding the detection reagent to each plate before reading. This ensures optimal and comparable results across plates.Emission Wavelength: The bioluminescence catalyzed by firefly luciferase exhibits a peak emission wavelength of 560 nm... Read More | The bacterial viability / toxicity detection kit contains two fluorescent dyes. Nucgreen is a green nucleic acid dye that can stain live and dead bacteria; Ethd III is a red nucleic acid dye that only stains dead bacteria with damaged cell membranes. When nucgreen and ethd III are properly mixed, The bacterial viability / toxicity detection kit contains two fluorescent dyes. Nucgreen is a green nucleic acid dye that can stain live and dead bacteria; Ethd III is a red nucleic acid dye that only stains dead bacteria with damaged cell membranes. When nucgreen and ethd III are properly mixed, the bacteria with intact cell membrane appear green, while the bacteria with damaged cell membrane can appear green and red under different channels, respectively. A common criterion for bacterial viability is the ability to propagate in a suitable nutrient medium, known as a growth assay. This kit is generally in good agreement with the growth assay results in liquid or solid medium. However, under certain conditions, membrane damaged bacteria may recover and propagate in nutrient medium, and such bacteria will be identified as dead bacteria in this assay. On the contrary, some bacteria with intact membranes may not be able to propagate in nutrient medium, but will be recognized as viable bacteria in this assay. Therefore, if there is a large difference between the test results of this kit and the bacterial growth assay, the above possibilities should be considered. Component: Product parameters: NucGreen: Ex/Em = 503/530 nm (结合 DNA);EthD-III: Ex/Em = 530/620 nm (结合 DNA)。Usage:1 Preparation of control samples for live and dead bacteria (optional)1. Cultivate 4 mL of bacteria in liquid medium until late logarithmic phase.2. Prepare two 1 mL bacterial solutions in an EP tube and centrifuge for 10-15 minutes under 5000-10000 g conditions.3. Remove the supernatant and add 0.3 mL of 0.85% NaCl resuspended bacteria to one of the EP tubes, and 1 mL of 0.85% NaCl resuspended bacteria to the other tube.4. Add 0.7 mL of isopropanol to a tube containing 0.3 mL of 0.85% NaCl, and mix thoroughly (with a final concentration of 70% isopropanol) to prepare a dead bacterial sample.5. Incubate the two samples at room temperature for 1 hour and mix every 15 minutes.6. Centrifuge the two samples at 5000-10000 g for 10-15 minutes.7. Remove the supernatant, add 1 mL of 0.85% NaCl to resuspend the bacteria in both samples, and centrifuge again as in step 6.8. Use a spectrophotometer to measure the absorbance values (OD670) of two bacterial suspensions at 670 nm.9. Adjust the density of the two bacterial suspensions (live and dead) to 108 bacteria/mL (OD670 ≈ 0.3), and then dilute with 0.85% NaCl at 1:100 to achieve a final density of 106 bacteria/mL.10. Mix two bacterial suspensions as shown in the table below to obtain the required live cell ratio: dead cell ratio.Table 1 Mix live and dead bacterial suspensions by a certain volume to achieve the required ratio of live and dead cellsLive cells: Dead cellsVolume of viable bacterial suspension(mL)Volume of dead bacterial suspension(mL)0:10001.010:900.10.920:800.20.830:700.30.750:500.50.5100:01.00II Staining methods for fluorescence microscopy observation1. Mix 1 volume of component A, NucGreen, and 2 volumes of component B, EthD-III, in a microcentrifuge tube. After thorough mixing, add 8 volumes of 0.85% NaCl solution to obtain a 100 x dye solution.2. Every 100 µ L bacterial suspension, add 1 µ 100 x dye solution of L.3. Mix thoroughly and incubate at room temperature in the dark for 15 minutes.4. Take 5 µ The bacterial suspension after L staining was dropped onto a glass slide with an 18 mm square cover glass.5. Observe under a fluorescence microscope. The fluorescence of live and dead bacteria can be observed simultaneously under any standard FITC long-acting filter. Alternatively, live (green fluorescent) and dead (red fluorescent) bacteria can be observed using FITC and Cy3 (or Texas Red) channels, respectively.Attention: (1) Before staining bacteria, attention must be paid to removing residues of growth media. Nucleic acid and other media components can bind to NucGreen and EthD-III dyes in some way, resulting in unacceptable staining changes. A simple washing step is usually sufficient to remove interfering media components from bacterial suspension. It is not recommended to use phosphate buffer solutions as they can reduce staining efficiency. (2) Before starting the formal experiment, the dye concentration should be adjusted to distinguish between NucGreen labeling live bacteria and EthD-III labeling dead bacteria. The optimal concentration may vary depending on the bacterial strain. It is generally best to use the lowest dye concentration that can provide sufficient signal. The above conditions have been optimized for staining live/dead cells of Escherichia coli.III Before starting the staining method experiment of flow cytometry, please read the precautions under the fluorescence microscope staining steps.According to Table 1, add 11 different proportions of live and dead bacteria to the EP tube. Each of the 11 samples has a volume of 1 mL.2. Add 12 µ The A component of L, NucGreen, and 24 µ The B component EthD-III of L was mixed in a microcentrifuge tube. Add 3 to each of the 11 samples µ Mix the mixed dyes of L thoroughly by blowing them up and down several times. (Note: Additional control bacterial samples need to be prepared for separate NucGreen and EthD-III staining)3. Incubate at room temperature in the dark for 15 minutes.4. Analyze each sample using a flow cytometer, detect NucGreen positive cells using FITC channels, and detect EthD-III positive cells using PI or PE channels.Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. if the orifice plate is used for detection, a small amount of bacterial liquid can be left for imaging after standing for 10 min, which can effectively reduce the background. 3. in order to be closer to the real results, it is recommended to keep the brightness of red fluorescence consistent with that of green fluorescence in merge pictures. 4. fluorescent dyes have quenching problems. Please try to avoid light during experimental operation to slow down fluorescence quenching. 5. for your safety and health, please wear experimental clothes and disposable gloves.Scope of application:Staining of dead and live bacteria... Read More | N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925 Component 1 mL 5 mL Storage N665925A 2×SYBR qPCR Master Mix 1 1 mL 5 mL -20℃. Avoid freeze/ Thaw cycle. N665925B qPCR Primer Mix 1 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925C DNA Standard I 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925D DNA Standard II 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925E DNA Standard III 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925F DNA Standard IV 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925G DNA Standard V 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665925H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is a real-time fluorescence quantitative PCR of the products after NGS library construction using a dye method (SYBR Green I).(qPCR). The kit provides the reaction mixes, DNA primer mixtures, standards and sample dilutions required for the qPCR process, making the reagent system complete and easy to use. The fluorescent dye SYBR Green I contained in the reaction mixture can bind to all double-stranded DNA; the GoldStar Taq DNA Polymerase used is a chemically modified new high-efficiency hot-start polymerase, and the activation of the enzyme needs to be incubated at 95℃ for 10 minutes. the product has high specificity, high amplification efficiency, and is able to quickly and accurately quantify the concentration of the constructed libraries. The product is highly specific and efficient in amplification, and can quickly and accurately quantify the concentration of the constructed library.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Ion torrent platform second generation sequencing libraries. The end of the library contains Ion torrent P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.005pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-CCA TCT CAT CCC TGC GTG TC - 3' Primer 2: 5'-CCT CTC TAT GGG CAG TCG GTG AT-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.Usage1. Amplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-50 pM. 4°C on ice was set aside.2. qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3. qPCR reaction program1) Please use 60-64℃ as a reference for setting range of annealing temperature, and increase the annealing temperature when non-specific reaction occurs.2) If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysis1. Standard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard I50 pMDNA Standard II5 pMDNA Standard III0.5 pMDNA Standard IV0.05 pMDNA Standard V0.005 pM2. Library concentration calculationThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attention1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the Products contentN665968Component96 TStorageN665968Adex N501-N508 Primers for Illumina 8×12 µL-20℃. Avoid freeze/thaw cycle.N665968BIndex N701-N712 Primers for Illumina 12×8 µL-20℃. Avoid freeze/thaw cycle. Products IntroductionThis kit is a companion kit for the transposase-based second-generation sequencing Rapid DNA Library Construction Kit, designed for Illumina platform library construction, which contains 8 primers at the N5 end and 12 primers at the N7 end, which can be used to prepare 96 different bipartite Index libraries. All reagents provided in the kit have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The prepared libraries can be sequenced on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes; tips: It is recommended to use high-quality filtration tips to prevent contamination of reagent kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.For the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501-N508 Primers for IlluminaIndex N701-N712 Primers for Illumina... Read More | Cell viability and cytotoxicity assays are usually used for drug screening and compound cytotoxicity testing. The CCK-8 kit uses highly water-soluble tetrazolium salt ( called WST-8 ) to produce water-soluble WST-8 for cell proliferation and cytotoxicity assays. Unlike MTT, WST-8 and WST-8 have no Cell viability and cytotoxicity assays are usually used for drug screening and compound cytotoxicity testing. The CCK-8 kit uses highly water-soluble tetrazolium salt ( called WST-8 ) to produce water-soluble WST-8 for cell proliferation and cytotoxicity assays. Unlike MTT, WST-8 and WST-8 have no cytotoxicity in cell culture medium, so multiple downstream experiments can be performed using the same detection plate. CCK-8 method is a convenient colorimetric method for the determination of cell viability. It does not need the solubilization process and only needs the least steps to provide the results. The CCK-8 method can be used for the determination of 96-well microplates and high-throughput screening of 384-well microplates. Advantage:At present, the commercially available liquid CCK-8 kits generally have defects such as harsh storage conditions ( -4C or -20 ), unstable use in different pH ranges, and easy deterioration ( discoloration or precipitation ). The solid instant CCK-8 kit adopts a new formula and Swiss process, which overcomes these shortcomings of the liquid CCK-8 kit. It can be stored at room temperature for a long time ( > 3 years ), ready to use, stable in a wide pH range, and the experimental results are more reliable. Compared with the liquid CCK-8 kit, the solid-soluble CCK-8 kit has higher sensitivity and the biological response time is shortened by half.Application scope:It can be used for drug screening, cell proliferation assay, cytotoxicity assay, tumor drug sensitivity test and activity detection of biological factors. Operating instructions:This reagent kit can be used for drug screening, cell proliferation assay, cytotoxicity assay, tumor drug sensitivity assay, and activity detection of biological factors.1. Carefully and slowly tear along the gap in the packaging bag;2. Pour all the powder in the bag into a clean container containing 10mL of ultrapure water, shake continuously for 1 minute, and use it when the solid is completely dissolved;3. Unused reagents must be stored at low temperatures below 4 ℃.Equipment required for testing:Enzyme reader 96 well plate with 450-490 nm filter;Carbon dioxide incubator;96 well plate, sterilized transparent plate for cell detection;Multi channel pipette (8 or 12 channels: 10-100 µ l);Blood cell counter or cell counter.Cell viability testing:1. Inoculate cell suspension (100 µ l/well) into a 96 well plate and pre culture the plate in a carbon dioxide incubator for 24 hours (37 ℃, 5% CO2);2. Add 10 µ l of CCK-8 solution to each well (be careful not to generate bubbles in the well as it may affect the reading of OD value);3. Incubate the culture plate in the incubator for 1-4 hours;4. Measure the absorbance at 450 nm using an enzyme-linked immunosorbent assay (ELISA) reader;5. If the OD value is not determined temporarily, 10 µ l of 0.1M HCI solution or 1% w/v SDS solution can be added to each well, and the culture plate can be covered and stored in the dark at room temperature. Within 24 hours of measurement, the absorbance will not change.Cell proliferation toxicity testing:1. Inoculate cell suspension (100 µ l/well) into a 96 well plate and pre culture the plate in an incubator for 24 hours (37 ℃, 5% CO2);2. Add 10ul of different concentrations of the substance to be tested to the culture plate;3. Incubate the culture plate in the incubator for an appropriate period of time (e.g. 6, 12, 24, or 48 hours);4. Add 10 µ l of CCK-8 solution to each well (be careful not to generate bubbles in the well as they may affect the reading of the OD value);5. Incubate the culture plate in the incubator for 1-4 hours;6. Measure the absorbance at 450nm using an enzyme-linked immunosorbent assay (ELISA) reader;7. If the OD value is not determined temporarily, 10 µ l of 0.1M HCI solution or 1% w/v SDS solution can be added to each well, and the culture plate can be covered and stored in the dark at room temperature. Within 24 hours of measurement, the absorbance will not change.Calculation method for cell survival rate/inhibition rate:Cell survival rate=[As Ab)/(Ac Ab)] x 100%Inhibition rate=[(Ac As)/(Ac Ab)] x 100%As: absorbance of experimental wells (including cells, culture medium, CCK-8 solution, and drug solution);Ac: absorbance of control wells (including cells, culture medium, CCK-8 solution, without drugs);Ab: Blank well absorbance (including culture medium and CCK-8 solution, excluding cells and drugs).Points for attention: 1.Unused reagents must be stored at low temperature below 4 °C, and stored in the dark at-20 °C for two years after unpacking, so as to avoid repeated thawing ; 2.The culture time of CCK-8 is generally 1-4 hours, but the naked eye can be taken out to observe the color degree in about 30 minutes. According to the cell type, the conditions need to be explored. The best reaction time of CCK-8 is based on the best time of specific color development.3. It is recommended to do a few holes to explore the number of inoculated cells and the culture time after adding CCK-8 reagent ; 3.The WST-8 in this kit will react with reducing agents ( such as some antioxidants ) to interfere with the detection. Before the cell proliferation-toxicity test, the background OD can be checked to confirm whether there is a reducing agent in the substance to be tested. If the effect of reducing agent needs to be removed, the fresh medium can be replaced before adding CCK-8 ( remove the medium, wash the cells twice with the medium, and then add the new medium ) ; 4.Phenol red in the medium does not affect the experimental results, and the absorbance of phenol red can be eliminated by deducting the absorbance of the background in the blank hole during calculation, so it will not affect the detection. 5.It is recommended to use a multi-channel pipette to reduce the difference between parallel holes. When adding CCK-8 reagent, it is recommended to add it obliquely to the wall of the culture plate, not to insert it under the liquid surface of the medium, which is easy to produce bubbles and interfere with OD determination. 6.If the drug contains metal, it has an effect on the color of CCK-8. The final concentration of 1mM lead chloride, ferric chloride and copper sulfate will inhibit the color reaction of 5 %, 15 % and 90 %, and reduce the sensitivity. If the final concentration is 10mM, the color reaction will be 100 % inhibited ; 7.When using a 96-well plate for detection, if the cell culture time is long, attention should be paid to the evaporation problem. On the one hand, because a circle around the 96-well plate is the easiest to evaporate, the method of discarding the surrounding circle can be adopted, and the same amount of PBS, water or culture medium can be added. On the other hand, the 96-well plate can be placed near the water source in the incubator to alleviate evaporation ; 8.When using standard 96-well plates, the minimum inoculation amount of adherent cells is at least 1,000 cells / well ( 100µl medium ). The sensitivity of detecting white blood cells is relatively low, so it is recommended that the inoculation amount should not be less than 2,500 cells / well ( 100 µl medium ). If you want to use a 24-well plate or a 6-well plate experiment, first calculate the corresponding inoculation amount per well, and add the CCK-8 solution according to 10 % of the total volume of the medium per well ; 9.Cell culture time varies according to the type and number of cells ( per well ), usually the color of white blood cells is weak, requiring a longer culture time ( 4 hours ) and a large number of cells ( ~ 105 cells / well ) ; 10.CCK-8 reagent is very low toxic to cells. The continuous reaction between it and dehydrogenase in living cells makes the color of the solution deepen and the OD value increase. The following methods can terminate the CCK-8 reaction ( 96-well plate ) : a ) After the color reaction, the culture plate was placed in a refrigerator at 4 ° C ; b ) 10µL 0.1MHCL solution was added to each well ; c ) 10 µL 1 % ( w / v ) SDS ( sodium dodecyl sulfate ) solution was added to each well. After the reaction stopped, the OD value should be measured within 24 hours. 11.To determine the specific number of cells, it is recommended to do the standard curve at the same time... Read More |