| Description | Inquire | Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 Products B669892Component50 TStorageB669892ABuffer RCL3×260 mL2-8℃B669892BBuffer GR25 mLRTB669892CBuffer GL25 mLRTB669892DBuffer GW1 (concentrate)13 mLRTB669892EBuffer GW2 (concentrate)15 mLRTB669892FBuffer GE15 mLRTB669892GProteinase K50 mgRTB669892HProteinase K Storage Buffer5 mLRTB669892ISpin Columns DL with Collection Tubes50 setsRTProductsThis kit is suitable for the extraction of total DNA, including genomic DNA, mitochondrial DNA and viral DNA, from fresh or frozen whole blood (blood samplestreated with anticoagulants such as citrate, EDTA or heparin), plasma, serum, haematocrit brown and yellow layers, bone marrow, cell-free body fluids, etc. Theproduct can process 1-5 ml of whole blood, and can be purified to obtain sizes rangingfrom 100bp to 50kb. The purified DNA is of high yield and good quality, with maximumremoval of proteins, pigments, lipids and other inhibitory impurities, and can bedirectly used in PCR, fluorescence quantitative PCR, enzyme digestion and SouthernBlot.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Add 5ml Proteinase K Storage Buffer to Proteinase K to dissolve it, and storeit at -20℃. Do not leave the prepared Proteinase K at room temperature for a longtime, and avoid repeated freezing and thawing to avoid affecting its activity.2. Repeated freezing and thawing of the sample should be avoided, as this may resultin smaller DNA fragments and a decrease in the amount of extracted DNA. 3.This kit can extract up to 1-5 ml of whole blood samples, if you need to extracta large number of blood samples, please use the blood genome non-column extractionkit. 4. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to theinstructions on the label of the reagent bottle before first use.5. Please check Buffer GL for crystallization or precipitation before use, if thereis any crystallization or precipitation, please put it in 56℃water bath to re-dissolve.6. If the downstream experiments are sensitive to RNA contamination, 4µl of DNaseFree RNase A (100mg/ml) can be added, RNase A is not provided in the kit, and canbe ordered separately from our company if needed.7. The Buffer RCL in the kit cannot be used further after turbidity.procedure1. Add 1-5 ml of blood sample to a centrifuge tube (supplied) and add 3 times thevolume of Buffer RCL and gently vortex or invert to mix.2. Centrifuge at 3000 rpm (~900 x g) for 10 minutes and carefully aspirate thesupernatant.3. Add 400 µl Buffer GR to the precipitate and resuspend the precipitate. Note: If the downstream assay is sensitive to RNA, add 4 µl of RNase A (100 mg/ml)solution, shake for 15 seconds, and leave at room temperature for 5 minutes.4. For 1-2 ml blood sample extraction, add 40µl Proteinase K to the above solutionand mix well; for 2-5 ml blood sample extraction, add 100µl Proteinase K to theabove solution and mix well.5. Add 400 µl of Buffer GL, mix upside down 15 times, and vigorously vortex andshake for at least 1 minute. Note: Do not add Proteinase K directly to Buffer GL.6. Incubate at 70°C for 10 minutes, during which time mixing was inverted severaltimes.Note: 1) If the solution is not completely clear, add appropriate amount of Proteinase K and incubate. Extend the incubation time until the solution is completely clear. 2) The yield of DNA has been maximized by 10 minutes of incubation, and continuedprolongation of the incubation time has no effect on DNA yield or purity.7. Add 400 µl of anhydrous ethanol and mix upside down 10 times. Centrifuge brieflyto concentrate the liquid on the walls and cap to the bottom of the tube.8. Add all of the solution obtained in the previous step to the Spin Columns DL inthe collection tube. If the solution cannot be added all at once, transfer it severaltimes. centrifuge at 12,000 rpm (~13,400 x g) for 1 minute, pour off the waste liquidfrom the collection tube, and put the column back into the collection tube.9. Add 500 µl of Buffer GW1 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: It is recommended that step 9 be repeated if the sample being extracted isthe blood genome of a species such as mice or monkeys from which hemoglobin isdifficult to remove.10. Add 500 µl Buffer GW2 to the adsorption column (check that anhydrous ethanolis added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquidin the collection tube, and put the adsorption column back into the collection tube.Note: Step 10 can be repeated if further DNA purity is required.11. Centrifuge at 12,000 rpm for 2 minutes and pour off the waste liquid in thecollection tube. Leave the adsorption column at room temperature for several minutesto dry thoroughly. Note: The purpose of this step is to remove residual ethanol from the adsorptioncolumn, which can interfere with subsequent enzymatic reactions (digestion, PCR,etc.)12. Place the adsorption column in a new centrifuge tube, add 50-200 µl of BufferGE or sterilized water to the middle of the adsorption column overhanging the column,leave it at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute,collect the DNA solution, and store the DNA at -20℃.Note: 1) If the downstream experiment is sensitive to pH or EDTA, you can use sterilized water for elution. The pH of the eluent has a great influence on theelution efficiency, if water is used as the eluent should ensure that its pH is7.0-8.5 (you can use NaOH to adjust the pH of the water to this range), and the elutionefficiency is not high when the pH is lower than 7.0.2) Incubation at room temperature for 5 minutes prior to centrifugation increasesyield.3) Re-elution with an additional 50-200 µl Buffer GE or sterilized water can increase the yield.4) If the final concentration of DNA is to be increased, the DNA eluate obtainedin step 12 can be re-spiked onto the adsorbent membrane and centrifuged at 12,000rpm. 1min; if the elution volume is less than 200µl, the final concentration of DNA canbe increased, but the total yield may be reduced. If the amount of DNA is less than1 µg, elution with 50 µl Buffer GE or sterilized water is recommended.5) Because DNA preserved in water is subject to acidic hydrolysis, for long-termstorage, it is recommended that it be eluted with Buffer GE and stored at -20℃... Read More | DescriptionCAR10 is a kit that contains a selection of 10 carbohydrates/sugars: Arabinose, Fructose, Galactose, Glucose, α-Lactose, Maltose, Mannose, Ribose, Sucrose and Xylose, which may be used for general research, as reagents or as reference compounds in analytical procedures | N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917 Component 1 mL 5 mL Storage N665917A 2×SYBR qPCR MasterMix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. N665917B qPCR Primer Mix 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917C DNA Standard A 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917D DNA Standard B 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917E DNA Standard C 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917F DNA Standard D 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917G DNA Standard E 100 µL 500 µL -20℃. Avoid freeze/ Thaw cycle. N665917H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis is a dye-based (SYBR Green I) qPCR NGS library quantification kit for cfDNA, which provides the reaction mixture, DNA primer mixture, standards, and sample dilutions required for the qPCR process, making it a complete reagent system that is easy and convenient to use. The fluorescent dye SYBR Green I contained in the reaction mixture binds to all double-stranded DNA. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, the length of the standard in the kit (about 270bp) is comparable to the average length of the cfDNA NGS libraries (250-300bp), which is able to quickly and accurately quantitate the concentration of the constructed cfDNA libraries. quantification.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.NOTE: High Rox and Low Rox are formulated as described in Method of Use 2.Applicable scopeThis product is designed for the absolute quantification of the concentration of Illumina platform second generation sequencing libraries. The end of the library contains Illumina P5 and P7 microarray binding sequences, the length of which does not exceed 1kb, and the concentration is not less than 0.02pM can be used for quantitative experiments. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-60 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR MasterMix10 µlqPCR Primer Mix0.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: 1 µl High Rox per 50 µl of reaction system; Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.3.qPCR reaction programIf the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.Refer to the specific instrument setup program for dissolution curves.data analysisStandard curve productionThe standard curve was plotted according to the data processing Excel sheet. The correlation coefficient R2 of the standard curve should be not less than 0.99, and the slope should be located between -3.1 and -3.6 when the Ct value is the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard A60 pMDNA Standard B6 pMDNA Standard C0.6 pMDNA Standard D0.06 pMDNA Standard E0.006 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency This reagent kit is specially developed for one-step RT-PCR experiments. Reverse transcription and PCR are carried out in the same reaction system, without the need to add reagents or open the tube cap during the reaction process, which improves detection sensitivity and experimental efficiency while avoiding contamination. This kit includes a brand new high-efficiency reverse transcriptase, a fast hot start DNA polymerase, as well as reaction buffer suitable for reverse transcription and PCR amplification, and other components necessary for the experiment. The loss of activity of SuperRT reverse transcriptase RNase H reduces RNA degradation in reverse transcription reactions. This reverse enzyme has high reverse transcription efficiency and can perform good reverse transcription reactions on a small amount of RNA templates. The rapid hot start DNA polymerase used in PCR reaction has excellent performance of high amplification efficiency, strong specificity, and fast extension speed. The unique buffering system maximizes the efficiency of both reverse transcriptase and polymerase. The target product amplified using this reagent kit has an A base attached to the 3 'end, which can be directly used for T/A cloning.S665660Component100 TStorageS665660ASuperRT OneStep EnzymeMix50 µL-20℃. Avoid freeze/thaw cycle.S665660B2×SuperRT OneStep Buffer1.4 mL-20℃. Avoid freeze/thaw cycle.S665660CRNase-Free Water1.5 mL-20℃. Avoid freeze/thaw cycle. Notes:1. During the operation process, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended to perform RNA operations in specialized areas, use specialized instruments and consumables, and have operators wear masks and disposable gloves, and frequently change gloves.2. Disposable plastic containers should be used as much as possible for experiments. If glass containers are used, they should be treated with a 0.1% DEPC (diethyl pyrocarbonate) aqueous solution at 37 ℃ for 12 hours, and sterilized under high pressure at 120 ℃ for 30 minutes before use. Alternatively, glass containers should be sterilized under dry heat at 180 ℃ for 60 minutes before use. The sterile water used in the experiment should be treated with 0.1% DEPC and then subjected to high-pressure sterilization.3. All reagents in this reagent kit should be gently mixed upside down before use, avoiding foaming as much as possible, and used after brief centrifugation. The enzymes involved should be returned to -20 ℃ as soon as possible after use to avoid repeated freeze-thaw cycles.4. This reagent kit must use specific primers, and the selection of primers can be based on specific experiments. The quality of primer design directly affects the results of RT-PCR reactions. When designing primers, factors such as GC content, primer length, primer position, and the secondary structure of PCR products need to be considered. It is recommended to use professional primer design software.Usage:1. Dissolve the RNA template, primers, OneStep RT-PCR Buffer, SuperRT OneStep RT-PCR EnzymeMix, and RNase Free Water and place them on ice for later use.2. Prepare the reaction system according to the following table: Reagent 25 µlReaction system Final concentration 2×SuperRT OneStep Buffer 12.5 µl 1× Forward Primer,10 µM 1 µl 0.4 µM Reverse Primer,10 µM 1 µl 0.4 µM SuperRT OneStep EnzymeMix 0.5 µl / RNA Template X µl 1 pg – 1 µg RNase-Free Water up to 25 µl / Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.3. Vortex and shake well, centrifuge briefly, and collect the solution to the bottom of the tube.4. Preheat the thermal cycler to 45 ℃, place the PCR tube in the thermal cycler, and perform RT-PCR reaction.Reaction conditions: Step Temperature Time / Reverse transcription 45℃ 30 min / PCR pre denaturation 95℃ 2 min Denaturation 94℃ 30 s 30-40 cycles Anneal 55-65℃ 30 s 30-40 cycles Extend 72℃ 30 s 30-40 cycles Finally extended 72℃ 5 min /Attention:1) In general PCR experiments, the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the annealing time is generally 20-30 seconds. If the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time is set based on the size of the amplified fragments, and the DNA Polymerase amplification efficiency contained in this product is 1 kb/30s.3) The number of cycles can be set based on the downstream application of the amplification product. Too few cycles, insufficient amplification; Multiple cycles increase the probability of mismatches and result in severe non-specific backgrounds. Therefore, while ensuring product yield, the number of cycles should be minimized as much as possible.5. After the reaction is complete, take 5 µ l of the reaction product, add an appropriate amount of loading buffer, and perform electrophoresis detection results... Read More |