| Description | Inquire | Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 Product content:E665636Component50 TStorageE665636ABuffer P115 mLRTE665636BBuffer P215 mLRTE665636CBuffer E315 mLRTE665636DBuffer PS15 mLRTE665636EBuffer PW (concentrate)10 mLRTE665636FEndo-Free Buffer EB10 mLRTE665636GRNase A (10 mg/mL)150 µLRTE665636HEndo-Remover FMwith Collection Tubes50 EARTE665636ISpin Columns DMwith Collection Tubes50 EART Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This reagent kit provides a simple, fast, and efficient new method for extracting endotoxin free plasmids. The extracted plasmids remove endotoxins to the maximum extent possible and can effectively remove contamination of genomic DNA, RNA, proteins, etc. The operation is simple and convenient. This reagent kit is suitable for extracting 1-5mL of bacterial solution. On the basis of alkaline lysis of cells, it efficiently and specifically binds plasmid DNA through a new silicon-based membrane. Each adsorption column can adsorb up to 40% µ The plasmid DNA of g is effectively removed using a special buffer system and endotoxin removal filter column, effectively removing impurities such as endotoxins and proteins. The plasmid obtained from this kit has high purity and stable quality, making it particularly suitable for cell transfection. It can also be used for downstream experiments such as DNA sequencing, PCR, PCR based mutations, in vitro transcription, transformed bacteria, and endonuclease digestion.Self prepared reagents: anhydrous ethanol, isopropanol.Preparation and important precautions before the experiment:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. 2. Before the first use, add all RNase A solution to Buffer P1, mix well, and store at 2-8 ℃. Before use, let it sit at room temperature for a period of time. After returning to room temperature, use.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Be careful not to come into direct contact with Buffer P2 and Buffer E3, and immediately cover them tightly after use.6.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.Operation steps:1. Take 1-5 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided). Centrifuge at 13000 rpm (~16200 × g) for 30 seconds to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 250 to the centrifuge tube containing bacterial sediment µ L Buffer P1 (please check if RNase A has been added first), mix thoroughly with a pipette or vortex oscillator, and suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity.3. Add 250 to the centrifuge tube µ L Buffer P2, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Leave at room temperature for 3-5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid. If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. Add 250 to the centrifuge tube µ L Buffer E3, immediately invert and mix 8-10 times until white flocculent precipitates appear. Let it stand at room temperature for 5 minutes. Centrifuge at 13000 rpm for 5 minutes, extract the supernatant, and add it to a filter column (Endo Remove FM). Centrifuge at 13000 rpm for 1 minute to filter, and collect the filtrate in a centrifuge tube (self provided).Attention: After adding Buffer E3, it should be mixed evenly immediately to avoid local precipitation. 5. Add 225 to the filtrate µ Mix L isopropanol upside down.6. Column balance: Add 200 to the spin columns DM that have been loaded into the collection tube µ L Buffer PS, centrifuge at 13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Transfer the mixed solution of filtrate and isopropanol from step 5 to an equilibrium adsorption column (already loaded into a collection tube).8.13000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum volume of the adsorption column is 750 µ L. If the sample volume is greater than 750 µ L can be added in batches. 9. Add 750 to the adsorption column µ L Buffer PW (please check if anhydrous ethanol has been added first), centrifuge at 13000 rpm for 1 minute, and discard the waste liquid in the collection tube.10. Place the adsorption column back into the recovery manifold and centrifuge at 13000 rpm for 1 minute. Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column in a new collection tube and add 50-100 to the middle of the adsorption membrane µ L Endo Free Buffer EB, let it stand at room temperature for 2-5 minutes, centrifuge at 13000 rpm for 2 minutes, and collect the plasmid solution into a centrifuge tube- Store the plasmid at 20 ℃.Note: 1) To increase the efficiency of plasmid recovery, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 13000 rpm for 2 minutes, and collected into a centrifuge tube.2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency... Read More | Inquire | Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Product content R669871Component50 TStorageR669871ADNase I1000 U-20℃. Avoid freeze/thaw cycle.R669871B10×Reaction Buffer1mL-20℃. Avoid freeze/thaw cycle. R669871CBuffer DS30 mLRTR669871DBuffer GTL15 mLRTR669871EBuffer GL25 mLRTR669871FProteinase K12.5 mgRTR669871GProteinase K Storage Buffer1.25 mLRTR669871HBuffer RW140 mLRTR669871IBuffer RW2 (concentrate)11 mLRTR669871JRNase-Free Water10 mLRTR669871KSpin Columns RS with Collection Tubes50 setsRTR669871LRNase-Free Centrifuge Tubes (1.5 mL)50 EART Product IntroductionThis kit is suitable for effectively purifying total RNA from formalin fixed and paraffin embedded tissues. Suitable for extracting total RNA with improved purity from paraffin embedded tissues or sections less than 30mg. This kit does not require the use of phenol/chloroform extraction or isopropanol precipitation, and can complete the extraction of multiple samples within one hour. This product uses specially optimized lysis solution and protease K to release RNA from formalin fixed or tissue slice samples without overnight operation; After digestion, the sample is incubated at a higher temperature to remove the inhibitory effect caused by formalin cross-linking, effectively releasing RNA from tissue slices and avoiding endangering RNA integrity; The optimized buffer system allows RNA in the lysis solution to specifically bind to the silica gel adsorption membrane, while other pollutants can flow through the membrane; It can be effectively removed through rinsing steps, and the washed RNA can be directly used for experiments such as RT-PCR, Real Time PCR, and Western blot analysis.Self prepared reagents: anhydrous ethanol (newly opened or dedicated for RNA extraction), 10mM PBS (pH 7.4).Preparation and important precautions before the experiment1. Add 0.625ml Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. After obtaining the sample, it should be fixed in 4% -10% formalin as soon as possible, with a suitable fixation time of 14-24 hours. Excessive time can lead to RNA breakage and affect downstream experiments.4. Ensure that the sample before embedding is thoroughly dehydrated, as residual formalin will inhibit the action of Protein K.5. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.Before use, please check if there is any crystallization or precipitation in Buffer GTL, Buffer GL, and Buffer DS. If there is any crystallization or precipitation, please dissolve Buffer GTL, Buffer GL, and Buffer DS again in a 56 ℃ water bath.Operation steps1. Sample processing1a. Paraffin embedded sample: Use a surgical knife to trim off excess paraffin from the tissue block, expose the tissue, and cut into 5-10 µ m thin slices.Attention: If the surface of the sample has already been exposed to air, please discard 2-3 pieces that come into contact with the air and do not use them.1b. Samples in fixed solutions such as formalin: Take approximately 20mg of the sample, cut it into small pieces, place it in a centrifuge tube, and add 500 µ 10mM PBS (PH7.4), vortex oscillation, centrifugation at 12000 rpm (~13400 × g) for 1 minute, discard the supernatant, repeat 3 times, and proceed directly to step 3.2. Choose option A or option B to remove paraffinOption AA1. Take approximately 1 × 1cm2 of slices (4-5 slices in total) and place them in a centrifuge tube (prepared by oneself), then add 500 slices µ L Buffer DS, vortex oscillation for 10 seconds. Incubate at 56 ° C for 3 minutes.Centrifuge at A2.12000 rpm for 2 minutes, be careful to discard the supernatant and avoid attracting sediment.Option BB1. Take approximately 4-5 slices of approximately 1 × 1 cm2 and place them in a centrifuge tube (self prepared). Add 1ml of xylene, cover the tube tightly, and vortex for 10 seconds.B2.Centrifuge at 12000 rpm for 2 minutes, be careful to remove the supernatant and avoid removing sediment.B3. Add 1ml of anhydrous ethanol, vortex and shake well. Centrifuge at 12000 rpm for 2 minutes, discard the supernatant, and be careful not to absorb or discard the sediment.B4. Open the tube cover and incubate at room temperature or up to 37 ° C for 10 minutes until there is no ethanol residue.3. Add 150µ L Buffer GTL, resuspended precipitation; Join 10µl Protein K, vortex oscillation mixing.4.Incubate at 56 ℃ for 15 minutes until the sample is completely dissolved. Incubate at 80 ℃ for 15 minutes. Short centrifugation allows the solution on the tube wall to be collected to the bottom of the tube.Note: 1) The purpose of this step is to repair nucleic acids denatured by formaldehyde. Incubating at a high temperature or for too long may cause RNA breakage, resulting in RNA fragments.2) The sample incubated at 56 ℃ can be placed at room temperature until the temperature of the water or dry bath reaches 80 ℃, and then the sample can be incubated at 80 ℃.5. Place on ice for 3 minutes, centrifuge at 12000 rpm for 15 minutes, transfer the supernatant to a new centrifuge tube, be careful not to suck sediment.6. Add 320 to the supernatant µ L Buffer GL, vortex oscillation thoroughly mixed.7. Join 720 µ Mix anhydrous ethanol thoroughly with vortex oscillation.Attention: After adding anhydrous ethanol, there may be a small amount of precipitate precipitation, but it does not affect subsequent operations.8. Add all the solutions obtained in step 7 to the spin columns RS that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred multiple times. Centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Optional steps: If genomic DNA needs to be removed, the following steps can be followeda. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.b. Preparation of DNase I mixture: Take 52 µ Add 8 RNase Free Water to it µ 10 x Reaction Buffer and 20 µ DNase I (1U/ µ l) Mix well and prepare to a final volume of 80 µ The reaction solution of L.c. Add 80 µ l of DNase I mixture directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.d. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.9. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.10. Repeat step 9.Centrifuge at 11.12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Place the adsorption column in a new RNase free centrifuge tube, and add 20-50µl to the middle of the adsorption column in the air Place RNase Free Water at room temperature for 2-5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -20 ℃.Note: 1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate. 2) If you want to increase RNA production, you can use 20-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 12... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More |