| Description | Fructokinase (FK, EC 2.7.1.4) regulates the interconversion between sucrose and starch and is involved in the regulation of plant metabolism and growth development. Fructokinase (FK) phosphorylates fructose to generate fructose-6-phosphate. This product is subsequently acted upon by a series of Fructokinase (FK, EC 2.7.1.4) regulates the interconversion between sucrose and starch and is involved in the regulation of plant metabolism and growth development. Fructokinase (FK) phosphorylates fructose to generate fructose-6-phosphate. This product is subsequently acted upon by a series of composite enzymes, reducing NADP+ to NADPH. The enzyme activity of fructokinase is determined by measuring the rate of increase in NADPH absorbance at 340 nm.Component100TStorageExtraction Buffer120 mL2-8℃Reagent 120 mL2-8℃Reagent 21EA-20℃Reagent 31EA-20℃Reagent 41EA2-8℃Reagent 51EA2-8℃Reagent PreparationReagent 2 (Powder, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 min to collect the powder at the bottom (tap manually if needed).Add 1.1 mL of distilled water to dissolve.The storage period is the same as the kit's expiry date.Reagent 3 (Liquid, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 min to collect the liquid at the bottom (tap manually if needed).Add 1.05 mL of distilled water to dissolve.The storage period is the same as the kit's expiry date.Reagent 4 (Powder, 1 vial):Before opening, ensure the powder is at the bottom of the vial (tap manually if needed).Add 17 mL of Reagent 1 to dissolve.The storage period is the same as the kit's expiry date.Reagent 5 (Liquid, 1 vial):Before use, centrifuge at 8000 g, 4°C for 2 min to collect the liquid at the bottom (tap manually if needed).Add 1.1 mL of distilled water to dissolve.The storage period is the same as the kit's expiry date.User-Prepared Instruments & MaterialsMortar (homogenizer), ice bucket (ice maker), benchtop centrifuge, adjustable pipettes, water bath (oven, incubator, metal bath), 96-well plate, centrifuge tubes, microplate reader, distilled water (deionized water or ultrapure water is acceptable).Sample Extraction1. Tissue Samples: Weigh approximately 0.1 g of tissue, add 1 mL of Extraction Buffer, and homogenize on ice. Centrifuge at 12000 rpm, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.Note: If increasing the sample amount, use a ratio of 1:5 to 1:10 (tissue weight (g) : Extraction Buffer volume (mL)) for extraction.2. Bacterial/Cell Samples: Collect bacteria or cells into a centrifuge tube by centrifugation and discard the supernatant. Take 5 million bacteria or cells, add 1 mL of Extraction Buffer, and disrupt using ultrasound on ice (power 20% or 200 W, ultrasonicate for 3 s, interval 10 s, repeat 30 times). Centrifuge at 12000 rpm, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.*Note: If increasing the sample amount, use a ratio of 1:1000~5000 (bacteria/cell count (x10⁴) : Extraction Buffer volume (mL)) for extraction.*3. Liquid Samples: Detect directly. If the sample is turbid, centrifuge and use the supernatant for detection.Assay Procedure1. Preheat the microplate reader for at least 30 minutes. Set the wavelength to 340 nm.2. Thaw all reagents to room temperature (25°C).3. In a well of the 96-well plate, add sequentially:Reagent (µL)Test WellSample20Reagent 210Reagent 310Reagent 4150Mix well and incubate at 37°C for 5 minutes. 4. Add:Reagent (µL)Test WellReagent 5105. Mix well. Immediately read the absorbance at 340 nm (A1) and then read again after incubating at 37°C for 20 minutes (A2). Calculate ΔA = A2 - A1.Notes:1. If ΔA is close to zero, the reaction time can be appropriately extended to 30 minutes or longer before reading A2; or the sample volume V1 can be increased appropriately (with a corresponding decrease in Reagent 4 volume). The modified reaction time (T) and sample volume (V1) must be substituted into the calculation formula.2. If the initial absorbance A1 is too high (e.g., >2, as in deeply pigmented plant leaves), appropriately reduce the sample volume V1. The modified V1 must be substituted into the calculation formula. Alternatively, add a small amount of activated carbon to the sample, mix, let stand for 5 min, then centrifuge at 12000 rpm, 4°C for 10 min, and use the supernatant for detection.3. If the increasing trend is unstable, read the absorbance every 10 seconds and select a linear increasing period for calculation. The corresponding ΔA value should be substituted into the calculation formula.FK Activity Calculation1. Based on Sample Protein Concentration:Unit Definition: One unit of enzyme activity is defined as the generation of 1 nmol NADPH per minute per mg of protein.Formula:FK (nmol/min/mg prot) = [ΔA ÷ (ε × d) × V2 × 10⁹] ÷ (Cpr × V1) ÷ T = 160.77 × ΔA ÷ Cpr2. Based on Sample Fresh Weight:Unit Definition: One unit of enzyme activity is defined as the generation of 1 nmol NADPH per minute per gram of fresh tissue.Formula:FK (nmol/min/g fresh weight) = [ΔA ÷ (ε × d) × V2 × 10⁹] ÷ (W × V1 ÷ V) ÷ T = 160.77 × ΔA ÷ W3. Based on Bacterial/Cell Density:Unit Definition: One unit of enzyme activity is defined as the generation of 1 nmol NADPH per minute per 10⁴ bacteria/cells.Formula:FK (nmol/min/10⁴ cell) = [ΔA ÷ (ε × d) × V2 × 10⁹] ÷ (500 × V1 ÷ V) ÷ T = 0.322 × ΔA4. Based on Liquid Volume:Unit Definition: One unit of enzyme activity is defined as the generation of 1 nmol NADPH per minute per mL of liquid.Formula:FK (nmol/min/mL) = [ΔA ÷ (ε × d) × V2 × 10⁹] ÷ V1 ÷ T = 160.77 × ΔAParameter Description:ε: NADPH molar extinction coefficient, 6.22 × 10³ L/mol/cmd: Light path of the 96-well plate, 0.5 cmV: Volume of Extraction Buffer added, 1 mLV1: Volume of sample supernatant added, 0.02 mLV2: Total reaction volume, 0.2 mL = 2.0 × 10⁻⁴ LT: Reaction time, 20 minW: Sample mass, g500: Cell number, in units of 10⁴Cpr: Protein concentration of the supernatant, mg/mL; Aladdin BCA Protein Quantification Kit (B665595) or Ready-to-Use BCA Protein Quantification Kit (R1491648) are recommended.Precautions It is recommended to first select 1-3 samples with significant differences (e.g., different types or groups) for preliminary experiments to familiarize yourself with the procedure. Determine or adjust the sample concentration based on the preliminary results to prevent unnecessary waste of samples or reagents... Read More | D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H D665729 Component 50 T Storage D665729A Conversion Buffer CR 5×1 mL RT D665729B Buffer CL 30 mL RT D665729C Buffer MD 0.4 mL RT D665729D Buffer DB 10 mL RT D665729E Buffer WB (concentrate) 10 mL RT D665729F Buffer GW1 (concentrate) 13 mL RT D665729G Buffer GW2 (concentrate) 15 mL RT D665729H Buffer EB 4 mL RT D665729I Buffer PS 10 mL RT D665729J Spin Columns DF 50 Pcs 2-8 ℃ D665729K Collection Tubes 50 Pcs RTProduct Introduction:The basic principle of this reagent kit is that after DNA is treated with sodium bisulfite, unmethylated cytosine can be transformed into uracil, while methylated cytosine remains unchanged. And adopting an innovative high-temperature treatment method, the transformation time is greatly shortened, the transformation efficiency is improved, and the transformation efficiency can reach over 99%. At the same time, using a silicon-based membrane purification column, DNA can be recovered and purified from the methylated solution through a simple binding washing elution step. The recovered DNA has high purity and good integrity, and can be directly used for sequencing, methylated PCR detection, chip analysis, connection and transformation, enzyme digestion, labeling, microinjection, PCR and in vitro transcription and other molecular biology experiments.Self prepared reagents: anhydrous ethanol, 75% ethanol.Preparation and important precautions before the experiment1. Product usage method:(1) 10 times packaging preparation method: CT Conversion Agent is a solid mixture that must be prepared before first use. Add 2 ml sterile water and 100 µ M-Dissolving Buffer and 300 µ Add M-Diffusion Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 10 DNA treatments. In order to achieve better results, the prepared CT Conversion Agent should be used immediately. If not used immediately, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.(2) 50 times packaging preparation method: CT Conversion Agent and M-Dissolving Buffer are solid mixtures that must be prepared before first use. Add 5 ml of sterile water to the M-Dissolving Buffer and shake to dissolve. After all the solids have dissolved, transfer all the solution from the M-Dissolving Buffer tube to the CT Conversion Agent tube and add 5.5 ml of sterile water. Add 1.5 ml of M-Dilution Buffer to the CT Conversion Agent tube. Dissolve at 55 ° C and shake until completely dissolved. Store the CT Conversion Agent solution at room temperature (20 ° C-30 ° C) in the dark before use. The CT Conversion Agent for each tube is designed for 50 DNA treatments. In order to achieve better results, the CT Conversion Agent should be used immediately after preparation. If not immediately used, the CT Conversion Agent solution can be stored at -20 ° C for 1 week. Before use, be sure to thaw the stored CT Conversion Agent solution at room temperature and mix thoroughly by shaking or inverting for 2 minutes, CT Conversion Reagent is sensitive to light, so it is important to minimize exposure to light as much as possible.2. Before the first use, anhydrous ethanol should be added to the M-Wash Buffer according to the instructions on the reagent bottle label.Operation stepsThe range of DNA prepared each time is 1 ng-4 µ Between g, the optimal amount is 500 ng-2 µ G.1. Take 20 µ Add DNA sample into centrifuge tube (self provided), and if the sample amount is insufficient, replenish with water up to 20 µ L.2. Add 2.2 to the DNA sample µ Mix the sample well with the M-Dilution Buffer of l.3.42 ℃ water bath for 30 minutes.4. Add 220 to the sample obtained from the previous step µ Prepare the CT Conversion Agent solution, mix well, and incubate in an 80 ℃ constant temperature water bath in a dark place for 60 minutes.5. Add 480 to the solution in the previous step µ M - Buffer PA, gently mix upside down.6. Column balance: Add 200 to the spin columns DS that have been loaded into the collection tube µ Centrifuge at 12000 rpm (~13400 × g) for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7.Add all the solution obtained from step 5 to the adsorption column (already loaded into the collection tube), let it stand at room temperature for 2 minutes, centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.Attention: The maximum capacity of the adsorption column is 750 µ l. If the sample volume is greater than 750 µ L can be added in batches.8. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute using M-Buffer PA, discard the waste liquid from the collection tube, and place the adsorption column in the recovery tube.9. Add 650 to the adsorption column µ M-Wash Buffer (please check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column in the collection tube.10.12000 rpm for 2 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).11. Place the adsorption column into a new centrifuge tube (provided by oneself), and add 20 drops to the middle position of the adsorption membrane in the air µ M-Elution Buffer (pH 8.5), leave at room temperature for 2 minutes. Collect DNA solution by centrifugation at 12000 rpm for 1 minute.12. Collect 20 µ Add 2.2 to DNA µ M-Diffusion Buffer, let it stand at room temperature for 30 minutes.13. Add 500 to the solution µ After pre cooling anhydrous ethanol, invert and mix well, and place the solution at -20 ℃ to precipitate for 30 minutes (overnight precipitation is more effective).14.12000 rpm for 15 minutes and gently discard the supernatant.15. Add 75% ethanol, centrifuge at 12000 rpm for 1 minute, pour out the supernatant, wait for ethanol to evaporate at room temperature, then add 20 µ Dissolve the M-Elution buffer and store the DNA at -20 ℃. The DNA collected in this step can be used for subsequent related experiments... Read More | Inquire | Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of Product DescriptionAcetyl esterase (sialate-O-acetylesterase) is a recombinant protein from Tannerella forsythia, ATCC 43037 strain, expressed in Escherichia coli. The enzyme removes acetyl groups attached via an O- group, mainly 9-, 8- and 7-. It can be used for monitoring of diacetylation of sialic acids on products such as erythropoietin (EPO).The Zyme Acetyl Esterase Kit removes 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins. It is commonly used for the characterization of highly-sialylated biotherapeutics such as EPO, FSH and blood clotting factors.Molecular Weight76.3 kDContentsAcetyl esterase – PBS pH7.5 buffer containing 10 mM Tris-HClReaction Buffer – 500 mM sodium acetate pH5.5Number of SamplesSufficient for up to 50 samples.Amount of SampleUp to 10 µg glycoprotein, up to 2.5 µg released glycans and up to 1 µg free sialic acid per digestion.Suitable SamplesAcetyl esterase (sialate-O-acetylesterase) can act upon complex glycoprotein samples, such as erythropoietin (EPO), bovine submaxillary mucin and oral epithelial cell-bound glycans, and on N- and O-glycans released from a glycoprotein. Either fluorescently labelled or unlabelled glycans are suitable. It can also be used on released sialic acids.Unit DefinitionOne unit (U) of acetyl esterase is defined as the amount of enzyme required to produce 300 µmole of 4-nitrophenol and acetate in 1 minute at 30°C in a buffer containing 50 mM Tris-HCl, 140 mM NaCl, pH 8.5, from 4-nitrophenyl acetate, a chromogenic esterase substrateStorageProtect from sources of heat and light. When stored correctly, the enzyme should be stable for 24 months from date of purchase. Exposure to ambient temperatures (20 – 26°C) over 3 days does not result in a reduction of enzymatic activity.ShippingThe product should be shipped at 4°C.HandlingEnsure that any glass, plastic ware or solvents used with this item are free of environmental carbohydrates. Use powder-free gloves for all sample handling procedures and avoid contamination with environmental carbohydrate.SafetyPlease read the Safety Data Sheets (SDSs) for all chemicals used. All processes involving labelling reagents should be performed using appropriate personal safety protection – safety glasses, chemically resistant gloves (e.g. nitrile), lab coat, and when appropriate, in a laboratory fume cupboard.For research use only. Not for human or drug use ApplicationAcetyl esterase (sialate-O-acetylesterase) can be used to remove 9-, 8- and 7-O-acetyl groups from released sialic acids, released glycans or glycoproteins... Read More | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More |