| Description | Inquire | Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples... Read More | This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be This kit is suitable for extracting total RNA from fresh whole blood (blood samples treated with anticoagulants such as citrate, EDTA, or heparin). It can process up to 1.5 ml of whole blood and elute to obtain high-purity RNA with a molecular weight greater than 200 bp. Multiple samples can be completed simultaneously within 1 hour. This product does not require the ultra centrifugation step of CsCl purification and LiCl or ethanol precipitation. It does not contain toxic solvents such as phenol or chloroform. The purified RNA effectively removes enzyme inhibitors and pollutants such as heme and heparin. It can be directly used in various molecular biology routine experiments, such as RT-PCR, Northern Blot, Dot Blot, in vitro translation, and so on.Self prepared reagents: β- Mercaptoethanol, 70% ethanol (prepared with water without RNase), anhydrous ethanol. R666034 Component 50 T Storage R666034A Buffer RBL (10×) 60 mL RT R666034B Buffer RL 35 mL RT R666034C Buffer RW1 40 mL RT R666034D Buffer RW2 (concentrate) 11 mL RT R666034E RNase-Free Water 10 mL RT R666034F Spin Columns FL with Collection Tubes 50 sets RT R666034G Spin Columns RM with Collection Tubes 50 sets RT R666034H RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RT Preparation and important precautions before the experimentTo prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction. The sample can be stored in Buffer RL at -70 ℃ for one month.3. Before use, please check if there is any crystallization or precipitation in the Buffer RL. It can be dissolved again in a 56 ℃ water bath. Please add Buffer RL before use β- Mercaptoethanol, with a final concentration of 1%. Add 10 to 1 ml Buffer RL µ L β- Mercaptoethanol. join β- The buffer RL room temperature of mercaptoethanol can be stored for one month.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. This reagent kit cannot be used for RNA extraction from frozen blood samples with anticoagulants added.6.10 × Buffer RBL needs to be diluted 10 times with water without RNase before use, and then stored at 2-8 ℃ after dilution.7. If downstream experiments are highly sensitive to DNA, it is recommended to treat RNA with DNase I that does not contain RNase.8. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Add 5 times the volume of 1 x Buffer RBL to fresh anticoagulant whole blood samples of 0.5-1.5 ml (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex or invert and mix well. Incubate on ice for 10-15 minutes, mix twice during the incubation process.Attention: During the incubation process, the cloudy suspension will become transparent, indicating that red blood cells have been lysed. If necessary, the incubation time can be extended to 20 minutes. 2. Centrifuge at 4 ℃, 2100 rpm (~400 × g) for 10 minutes, and carefully discard the supernatant.3. Add 2 times the volume of the blood sample to the above precipitate with 1 x Buffer RBL (please dilute 10 x Buffer RBL with RNase free water before use), gently vortex, and resuspend the precipitate thoroughly. 4. Centrifuge at 4 ℃ and 2100 rpm for 10 minutes, carefully and thoroughly remove the supernatant.Note: This step must completely remove the supernatant, otherwise it will affect the lysis and lead to a decrease in RNA production.5. Add Buffer RL to the precipitate (check if it has been added before use β- Mercaptoethanol, 0.5-1.5 ml of blood sample added to 600 µ L Buffer RL, or less than 0.5 ml of blood sample added to 350 µ L Buffer RL, mix well.6. Transfer the obtained liquid to the spin columns FL that have been loaded into the collection tube, centrifuge at 12000 rpm (~13400 × g) for 2 minutes, collect the filtrate, and discard the filter column.7. Add 1 volume (600) to the obtained filtrate µ L or 350 µ l) Mix 70% ethanol (prepared without RNase water) well.Attention: Adding ethanol may cause precipitation and will not affect subsequent experiments.8. Add all the solution obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 700 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.Optional steps: If conducting RNA experiments that are highly sensitive to trace amounts of DNA, replace step 9 with the following steps.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.1) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.2) Preparation of DNase I mixture: Take 70 µ Reaction Buffer and 10 µ L DNase I storage solution, gently mix and prepare to a final volume of 80 µ The reaction solution of L.Attention: The above system is configured according to our company's DNase I (D665537) reaction system. Please refer to the corresponding manual for other company products.3) Add 80 µ l of the prepared DNase I reaction solution directly to the adsorption column and incubate at 20-30 ℃ for 15 minutes.4) Add 350 to the adsorption column µ Centrifuge at 12000 rpm for 15 seconds, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.10. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 15 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Repeat step 10. 12. Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 13... Read More | This reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the siliconThis reagent kit uses an adsorption column that can specifically bind to viral RNA and a unique buffer system, suitable for isolating viral RNA from cell-free body fluids such as serum, plasma, urine, cerebrospinal fluid, and cell culture supernatants. The viral RNA specifically binds to the silicon substrate membrane, and pollutants flow through the membrane. Completely remove impurities such as proteins through two efficient washes, and then wash high-purity viral RNA with RNase free water or RNase Free Water provided by the reagent kit. The virus RNA extracted by this kit can be directly used for experiments such as RT-PCR, Real time RT-PCR, and Western blot analysis. R666005Component50 TStorageR666005ABuffer GL15 mLRTR666005BBuffer RW140 mLRTR666005CBuffer RW2(concentrate)11 mLRTR666005DProteinase K12.5 mgRTR666005EProteinase K Storage Buffer1.25 mLRTR666005FRNase-Free Water10 mLRTR666005GSpin Columns RS with Collection Tubes50 setsRTR666005HRNase-Free Centrifuge Tubes(1.5 mL)50 EART Self prepared reagent: anhydrous ethanol, 0.9% NaCl.Preparation and important precautions before the experiment1. Add 1.25 ml of Protein K Storage Buffer to Protein K to dissolve it and store at -20 ℃. The prepared Protein K should not be left at room temperature for a long time to avoid repeated freeze-thaw cycles, which may affect its activity.2. To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.3. Serum or plasma should avoid repeated freeze-thaw cycles that may cause protein denaturation or precipitation, reduce viral titers, and thus affect the yield of extracted viral nucleic acids.4. Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. If buffer GL precipitates, it can be heated at 56 ℃ to dissolve and then placed at room temperature.6. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps1. Take 200 at room temperature µ Add serum or plasma to a 1.5 ml centrifuge tube (self provided). Attention: Less than 200 µ 0.9% NaCl (provided by the customer) can be added to make up for it.2. Add 20 to the solution in the previous step µ Protein K, mix well.3. Add 200 µ L Buffer GL, vortex oscillation for 15 seconds. Note: Do not directly add Protein K to Buffer GL. 4. Incubate at 56 ℃ for 15 minutes, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube.5. Add 250 µ Anhydrous ethanol, vortex for 15 seconds, incubate at room temperature for 5 minutes, briefly centrifuge, and collect the solution from the tube wall to the bottom of the tube.6. Add all the solution obtained in step 5 to the Spin Columns RS that have been loaded into the collection tube. If it is not possible to add all the solution to the adsorption column at once, please transfer it in two batches, centrifuge at 12000 rpm (~13400 × g) for 1 minute, discard the waste liquid in the collection tube, and put the adsorption column back into the collection tube.7. Add 500 to the adsorption column µ Centrifuge at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube.8. Add 500 to the adsorption column µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 1 minute, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Add 500 to the adsorption column µ Centrifuge anhydrous ethanol at 12000 rpm for 1 minute, discard the waste liquid from the collection tube, and place the adsorption column back into the collection tube. 10. Centrifuge at 12000 rpm for 3 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes to thoroughly air dry.Attention:1) The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).2) Recommended steps: Place the adsorption column into a new 1.5 ml centrifuge tube (provided), open the tube cover, and incubate in a 56 ℃ oven for 3 minutes to thoroughly dry the membrane of the adsorption column.11. Place the adsorption column in a new RNase free centrifuge tube and add 20-50 to the middle of the adsorption column in the air µ Place RNase Free Water at room temperature for 5 minutes, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 20 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 20-50 µ Repeat step 11 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 11... Read More | Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, Products contentProducts IntroductionThe Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 µg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.Bring your own instruments and reagentsPCR instrument Reaction tubes: low adsorption tubes recommended Gun Heads: High quality filtered gun heads are recommended Microcentrifuge, vortex mixercaveat The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.Operation flow diagramprocedurePre-experiment preparationSingle cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+, taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl. take note of Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.cell lysis 1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.2. Pre-amplification reaction1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.2)Add 5 µl of pre-amplification mix to 10 µl of lysis reaction product from the previous step and run the following program. 3. Amplification reaction1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.2)Add 60 µl of amplification mix to 15 µl of pre-amplification reaction product from the previous step and run the following program.Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.Amplification product detection 1. Agarose gel electrophoresis 5 µl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size. 2. Quantitative Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 µg... Read More |