| Description | The Hoechst33258/PI Apoptosis Assay Kit is a detection kit that uses a dual fluorescence staining method with Hoechst 33258 and Propidium Iodide (PI) to analyze cell cycle and cell necrosis. While PI staining alone can observe the sub-G1 peak of apoptotic cells on the DNA histogram, it can only The Hoechst33258/PI Apoptosis Assay Kit is a detection kit that uses a dual fluorescence staining method with Hoechst 33258 and Propidium Iodide (PI) to analyze cell cycle and cell necrosis. While PI staining alone can observe the sub-G1 peak of apoptotic cells on the DNA histogram, it can only represent apoptosis in the G0/G1 phase and cannot observe apoptosis in the S and G2 phases. Moreover, after fixation, it is impossible to distinguish between live and dead cells. Hoechst 33258 can penetrate the cell membrane and bind to DNA in both normal and apoptotic cells, showing blue fluorescence under ultraviolet light. After staining, the fluorescence of apoptotic cells is significantly enhanced compared to normal cells. PI cannot penetrate the cell membrane and cannot stain normal or apoptotic cells with intact cell membranes. However, for necrotic cells, where the integrity of the cell membrane is lost, PI can penetrate the cell membrane and color the necrotic cells to produce red fluorescence. When these two dyes are used for double staining, normal cells appear weak blue, apoptotic cells appear bright blue, and necrotic cells appear bright blue and red.ComponentH1492197Component100TStorageQuantity Per TestH1492197AHoechst 33258 Staining Solution1 mL-20℃, Store in the dark.10 µL per 0.5-1.0x10⁶ H1492197BPropidium iodide Staining Solution (PI)0.5 mL-20℃, Store in the dark.5 µL per 0.5-1.0x10⁶ Note: The recommended number of cells to stain per test 0.5–1.0×10⁶ cells.Usage method:1. Cell PreparationAdherent cells: Grow cells in 6-well plates to the logarithmic growth phase. Wash twice with PBS and add 1 mL of PBS.Suspension cells: Wash cells twice with pre-cooled PBS and resuspend in PBS at a density of 0.5–1.0×10⁶ cells/mL.2. StainingAdherent cells: Add 10 µL of Hoechst 33342 and 5 µL of PI directly to each well of the 6-well plate. Incubate at 4 °C in the dark for 20–30 minutes.Suspension cells: Take 1 mL of the cell suspension, add 10 µL of Hoechst 33342 and 5 µL of PI, and incubate at 4 °C in the dark for 20–30 minutes.Note: After staining, proceed with fluorescence detection as soon as possible. The number of cells for each detection should not exceed 1×10⁶.3. Fluorescence Microscopy Detection and AnalysisAdherent cells: Remove the staining solution, wash twice with PBS, add an appropriate amount of PBS, and observe under a fluorescence microscope.Suspension cells: Wash twice with PBS, resuspend the cells in PBS, transfer to a culture dish, and observe for red and blue fluorescence.Matters needing attention:1. After the staining process is completed, the detection should be carried out as soon as possible.Hoechst 33258 and PI are harmful to the human body. Please take protective measures when using them.2. For your safety and health, please wear a laboratory coat and put on disposable gloves when operating.3. This product is exclusively for scientific research purposes and must not be used for clinical diagnosis or treatment... Read More | DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) DescriptionTruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) quantify all the biochemicals in the sample relative to their counterparts in the Internal Standard, b) suppression-correct each compound and c) normalize sample to sample variances; and (2) injecting the same well characterized Long-Term Reference Standard (WORKFLOW-B) to create a daily retention time (RT) library of all compounds to be found in the Internal Standard for reproducible ID, and to measure day-to-day (QA/QC) to assure reproducible instrument performance. The system is completely automated using IROA ClusterFinder™software.IROA TruQuant IQQ Workflow Kit contains the materials and tools for the analysis of 90 experimental samples. The kit is intended to be used for mass spectrometry metabolomics applications... Read More | S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid S665948 Component 1 mL 5 mL Storage S665948A 2×SYBR qPCR Master Mix 1 mL 5×1 mL -20℃. Avoid freeze/ Thaw cycle. S665948B qPCR Primer Mix 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948C DNA Standard 1 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948D DNA Standard 2 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948E DNA Standard 3 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948F DNA Standard 4 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948G DNA Standard 5 100 µL 5×100 µL -20℃. Avoid freeze/ Thaw cycle. S665948H 50×High ROX 40 µL 200 µL -20℃. Avoid freeze/ Thaw cycle.Product IntroductionThis product is used for real-time fluorescence quantitative PCR (qPCR) using the product after NGS library construction by dye method (SYBR Green I). The kit provides the reaction mixture, DNA primer mixture, and standards required for the qPCR process, and the reagent system is complete, easy and convenient to operate. The kit uses a new chemically modified high-efficiency hot-start polymerase, the activation of the enzyme needs to be incubated at 95 ℃ for 10 min. the product is highly specific, high amplification efficiency, and able to quickly and accurately quantify the concentration of the constructed library. It is suitable for fluorescent quantitative PCR instruments that do not require ROX as a calibration dye, such as Roche LightCycler 480, Roche LightCyler 96, Bio-radiCyleriQ, iQ5, CFX96.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.Note: High Rox and Low Rox are formulated as described in Use 2.Scope of applicationThis product is designed for absolute quantification of the concentration of Illumina platform second-generation sequencing libraries. The end of the library contains Illumin P5 and P7 chip binding sequences, the length of which does not exceed 1kb, and the concentration of which is not less than 0.002pM can be used to perform quantitative experiments with this product. The qPCR Primer Mix provided in the kit contains the following two primer sequences:Primer 1:5'-AAT GAT ACG GCG ACC ACC GA-3' Primer 2: 5'-CAA GCA GAA GAC GGC ATA CGA-3'The primer sequence can be used in advance to confirm whether the library can be amplified by that primer pair.UsageAmplification template preparationThe library samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.01-20 pM. 4°C on ice was set aside.qPCR reaction system preparationThe desired cryopreservation reagent is pre-melted completely and mixed by inverting several times before preparation, then centrifuged briefly and set aside.The base reaction system for 20 µl was as follows:Reagent20 µl Reaction system2×SYBR qPCR Master Mix10 µlqPCR Primer Mix 10.8 µlTemplate4 µlddH₂O5.2 µlDescription: High Rox model: add 1 µl High Rox per 50 µl of reaction system;Low Rox model: 1 µl High Rox per 500 µl of reaction system.Prepare a sufficient amount of reaction system mixture according to the need, mix well and add to the reaction wells in a volume of 16 µl per well, add the same volume of TE to the blank control, and then add the prepared standards and diluted samples to the corresponding reaction wells in a volume of 4 µl/well. It is recommended to use 20 µl reaction system, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.qPCR reaction programThe annealing temperature should be 60-64°C as a reference for the setting range, and the annealing temperature can be increased when a non-specific reaction occurs.If the average length of the library is greater than 700bp, the annealing/extension time should be increased appropriately.data analysisStandard curve productionThe standard curve was plotted using Ct values in the valid range. The standard curve correlation coefficient R2 should not be less than 0.99 and the slope should lie between -3.1 and -3.6. If the standard curve parameters are not reasonable, it is recommended to repeat the experiment.DNA Standard NameDNA Standard ConcentrationDNA Standard 120 pMDNA Standard 22 pMDNA Standard 30.2 pMDNA Standard 40.02 pMDNA Standard 50.002 pMLibrary Concentration CalculationsThe difference in Ct between the three replicate wells of the experiment should be no more than 0.2, otherwise the invalid data should be deleted or the experiment should be repeated. Do not use the Ct outside the valid Ct range of the standard curve to calculate the concentration of the diluted libraries. Please refer to the data processing Excel of this product for the specific library concentration calculation method.matters needing attentionThese instructions should be read in detail before testing. It should be carried out by personnel with specialized experience or qualified by training.Mix gently by turning up and down, avoid foaming as much as possible, and centrifuge for a short time before use.Avoid repeated freezing and thawing of this product; repeated freezing and thawing may degrade product performance.When preparing reaction solutions, use new or non-contaminated tips and centrifuge tubes to prevent contamination as much as possible... Read More | Component Description T665563Component50 TStorageApplicationT665563AVNTR3820 1 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563BVNTR41201 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563CVNTR32321 mL-20℃. Avoid freeze/thaw Component Description T665563Component50 TStorageApplicationT665563AVNTR3820 1 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563BVNTR41201 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563CVNTR32321 mL-20℃. Avoid freeze/thaw cycle.High resolution 3-lite VNTR detectionT665563DMarkerⅠ300 µL-20℃. Avoid freeze/thaw cycle.DNA Molecular Weight Standard IT665563EMarkerⅡ250 µL-20℃. Avoid freeze/thaw cycle.DNA Molecular Weight Standard IIProduct IntroductionThis kit is a genotyping product for human Mycobacterium tuberculosis based on the latest research progress in molecular epidemiology1) and optimized by process. It utilizes variable-number tandem repeats (VNTR) polymorphisms in the Mycobacterium tuberculosis genome for genotyping to differentiate clinical strains, and is a powerful tool for studying the molecular epidemiology of Mycobacterium tuberculosis and monitoring the status of tuberculosis transmission. Compared with other existing Mycobacterium tuberculosis VNTR typing systems based on the VNTR principle, this typing system has a stronger ability to discriminate strains prevalent in China1,2,3), and is therefore particularly suitable for the needs of Chinese users.By carefully optimizing the primer sequences of each PCR reaction and the composition of the premixed reaction solution, this product has a strong anti-interference power. Compared with the user's own reagents, this product significantly improves the signal intensity of specific bands and reduces the appearance of non-specific bands when using crude templates (boiling bacterial solution), which makes the experimental operation easier and quicker, and at the same time, improves the success rate of the test. The premixed reaction solution is chemically stable and can effectively withstand repeated freezing and thawing (10 times) and a longer period of time (one week) at room temperature, which is better adapted to the user's need for flexibility in the detection work.This kit is a companion product to the TB Genotyping Kit VNTR-9. For samples identified as clustered or identical strains by the VNTR-9 kit, this product can be used for finer further typing identification if necessary. The three high-resolution detection sites VNTR3820, VNTR4120 and VNTR3232 in this product can be used in combination with the nine detection sites in the VNTR-9 to increase the resolution index (Hunter-Gaston index (HGI) to 0.9931).References1) Luo T et al. Development of a hierarchical variable-number tandem repeat typing scheme for Mycobacterium tuberculosis in China. PLoS One. 2014 Feb 25. 9(2)2)Sun G et al. Discriminatory potential of a novel set of Variable Number of Tandem Repeats for genotyping Mycobacterium marinum. Vet Microbiol. 2011 Aug Vet Microbiol. 2011 Aug 26;152(1-2)3) Zhang L et al. Highly polymorphic variable-number tandem repeats loci for differentiating Beijing genotype strains of Mycobacterium tuberculosis in Shanghai, China. FEMS Microbiol Lett. 2008 May;282(1):22-31.matters needing attention1.This product is a companion to the TB genotyping kit VNTR-9. The strains to be tested should be tested by VNTR-9 typing test first, and then use this product for testing. And the results of this product should be integrated and analyzed with the results of VNTR-9.2.To avoid contamination, it is recommended that the preparation of the organisms be done within a different location than the preparation of the PCR Mix and that different pipettes be used.3.Care should be taken at all stages of sample DNA collection, extraction and amplification to ensure proper labeling and to prevent cross-contamination between different samples.4.Commonly used reagents and consumables need to be autoclaved before experimentation.5.Each tube of PCR Mix contains different primers and cannot be mixed. It can be dispensed into different amounts at once according to the experimental needs to avoid repeated freezing and thawing.6.To avoid splashing the reaction solution when opening the reaction tube, centrifuge briefly before opening the cap and collect the liquid at the bottom of the tube. In case of accidental splashing on gloves or table, change gloves immediately and wipe the table with 75% alcohol or dilute acid.7.Be careful not to cross-contaminate the PCR Mix when aspirating, and it is recommended that the pipette tip be wiped with 75% alcohol 2 times before taking Mix each time.8.Pre-experiment preparation: 1×TE buffer (PH=8.0), 0.5×TBE buffer, agarose, ethidium bromide (EB), normal PCR instrument, DNA electrophoresis equipment and gel imager, 0.2 ml PCR reaction tubes, octuplex or 96-well PCR tubes, pipettes of different sizes: 0.5-10 µl and 20-200 µl.Operation steps1. DNA template preparation:1.1. scrape a small amount (1-2 inoculation loops) of sample from solid medium, resuspend in 100ul TE and inactivate at 80°C for 30 minutes.1.2. The inactivated strain was taken out of the P3 laboratory as follows:Boil at 100°C for 10 minutes (be careful to avoid bursting the cap of the EP tube during boiling to avoid letting water into the tube), place immediately on ice for 2 minutes, centrifuge at 12,000 rpm (~13,400 × g) for 10 minutes, take the supernatant and place in another sterile EP tube, label it, and store at -20°C.2. Testing procedures:2.1. Remove the TB Genotyping Kit HV-3, allow the liquid to equilibrate to room temperature, mix by shaking slightly 3-4 times, and then centrifuge at 12,000 rpm (~13,400 x g) for 5 seconds to allow the capped liquid to fall back into the tube.2.2.Three-locus VNTR typing: strains with identical results at 12 loci need to be further VNTR typed, i.e., the following four loci are added for comparison.1)PCR amplification: the reaction system was 20 µl. 19 µl of PCR Mix of VNTR3820, VNTR4120, and VNTR3232 were added to each PCR tube, 1 µl of DNA template was added, and mixed well.2)Amplification conditions:3) Gel preparation and electrophoresis:a: Notes:Important! Positive (H37Rv strain DNA) and negative controls (deionized water) need to be set up for each experiment.Key! This experiment is based on agarose gel electrophoresis to interpret the genotype of VNTR locus, therefore, in order to make the results accurate, it is necessary to follow the unified standard operation in this step of electrophoresis, and the following points should be noted:a-1: The comb used for glue making is 18 holes.a-2: The two wells on the left and right sides of the gel were discarded due to the tendency to distort the bands during electrophoresis, affecting the interpretation of the results, or a negative control was spotted in one of the wells. The remaining 16 wells were divided into 12 samples, 3 DNA Markers and 1 positive control. The order of spotting was "1, 2, M, 3, 4, 5, 6, M, 7, 8, 9, 10, M, 11, 12, H37Rv", the numbers represent samples, and M represents DNA Marker.a-3: When PCR amplification products are subjected to the first electrophoresis and Marker I is used, the gel concentration is 1%, the voltage is 150 V, and the time is 100-120 min.a-4: If the amplification product fragment is too large (>1000bp) and needs to be electrophoresed again and Marker II is used, the gel concentration is 0.8%, the voltage is 150V and the time is 150 minutes.b: Gluing as well as the electrophoresis process:PCR amplification products were electrophoresed using a 1% agarose gel.To prepare 1% agarose gel, 12×12 cm gel tray was used to make the gel, each gel was 80 ml.b-1: Weigh 0.8g of agarose, add 80ml of 0.5×TBE, weigh it on the balance and put it into the microwave oven, heat it on high for 2-3 minutes to make the agarose dissolve completely, shake it well, and observe it as a homogeneous and transparent solution without particles, then weigh it again on the balance and make up the appropriate amount of double-distilled water to keep the concentration of the gum unaffected.b-2: When the melted gel was cooled to about 55°C add 4 µl of ethidium bromide (10ug/ml) and gently swirl to mix well. The gel was made with an 18-tooth comb and the warm gel was poured into a 12 × 12 cm gel tray.b-3: Allow the gel to completely set (40 minutes at room temperature), carefully pull out the comb, remove the tray, and place it in the electrophoresis tank. Add 0.5× TBE buffer to the electrophoresis tank, not exceeding the gel surface by 1-2mm.b-4: Sample electrophoresis: add 12 samples to each gel (the topmost wells are not sampled), add 3-5µl PCR products to each well, and at the same time add three 5µl DNA MarkerⅠ to each gel. The voltage is 150V and the electrophoresis time is 100-120 minutes. This step is the key to the accuracy of the final readings of each point, and needs to be operated uniformly according to this standard.b-5: Some loci have amplification products greater than 1000bp in clinical strains, and these amplification products were then electrophoresed using 0.8% agarose gel, with DNA Marker II added as a control for the band size, voltage 150V, electrophoresis time 150 minutes.4) Results display:5) Analysis of results:a. If the genotypes of the three highly variable loci are also the same in different strains, they can be identified as clustered strains;b. If the high variant readings are highly similar, i.e., only 1-2 high variant sites are different, they need to be combined with epidemiologic data to identify if they are clustered strains;c. If all 3 high variant loci are genotypically discordant, identify as a single strain.Appendix 1: Rules for reading VNTR lociAppendix 2: VNTR locus repeat unit readout table... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |