| Description | The content of this cell is too long for an XLSX file (more than 32767 characters). Please use the CSV format for this export | Products contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-endProducts contentN665989Component240 TStorageN665989AIndex N501 Primers for Illumina240 µL-20℃. Avoid freeze/ Thaw cycle.N665989BlIndex N901-N924 Primers for Illumina24×10 µL-20℃. Avoid freeze/ Thaw cycle.Note: The amount of individual primers used is 1 µl, each N7-end primer can perform 10 DNA library constructs, and each kit can perform 240 DNA library constructs. Products IntroductionThis kit is a companion kit to the transposase-based Rapid DNA Library Construction Kit for Illumina platform library construction. Each kit contains one N5 primer and 24 N7 primers, which can be used to prepare 24 different single-ended Index libraries. All reagents provided in the kits have been subjected to stringent quality control and functional validation to maximize the stability and reproducibility of library construction. The libraries can be used for sequencing on Illumina platforms such as HiSeq X-10/4000/2500/2000 and MiSeq. Provide your own instruments, reagents and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use Kangwei DNA purification and recovery kit by magnetic bead method.3. DNA building kit: It is recommended to use the Kangwei Century transposase method second-generation sequencing rapid DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples. Pre-experiment Preparation and Important NotesPlease centrifuge briefly before opening the cap so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. ProcedureFor the use of the CombiVision Second Generation Sequencing Multisample Primer Kit, please follow the CombiVision Second Generation Sequencing Rapid DNA Library Kit protocol.Index N501 Primer for IlluminaIndex N901-N996 Primer for Illumina... Read More | DescriptionMaterials included in the kit are designed to be used with the Hy-Energy′s PCTPro-2000 System. They also can be used for demonstration purposes and as standards during the development of novel hydrogen storage and battery materials | Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products content S666097Component200 TStorageS666097A5×SuperFast One Step RT-qPCR U+ Buffer1 mL-20℃. Avoid freeze/thaw cycle.S666097BSuperFast One Step U+ Enzyme200 µL-20℃. Avoid freeze/thaw cycle.S666097CRNase-Free Water2×1.5 mL-20℃. Avoid freeze/thaw cycle. Products IntroductionThe SuperFast Probe One Step RT-qPCR U+ Kit is designed for quantitative PCR assays using RNA as a template (e.g., RNA viruses). Using gene-specific primers (GSP), reverse transcription and qPCR reactions are completed in a single tube, eliminating the need for additional tube-opening/pipetting operations, greatly increasing throughput and reducing the risk of contamination. The dUTP/UNG anti-contamination system is introduced in this kit. The heat-sensitive UNG rapidly degrades U-containing contaminants at room temperature; it is rapidly inactivated by reverse transcription at 55°C, without affecting the efficiency and sensitivity of qRT-PCR. Combined with optimized buffer systems and antibody-modified Taq enzymes and mutated M-MLV, the SuperFast Probe One Step RT-qPCR U+ Kit provides sensitivity up to 0.1 pg of total RNA or <10 copies of RNA template and enhanced thermal stability. 5× SuperFast One Step RT-qPCR U+ Buffer contains the following components The 5× SuperFast One Step RT-qPCR U+ Buffer contains an optimized buffer system and dNTP/dUTP Mix, which is particularly suitable for high specificity, low template concentration and multiplexed rapid detection of fluorescently labeled probes such as TaqMan. caveatBefore use, please mix the product gently by turning it up and down after it is completely melted to avoid foaming, and use it after brief centrifugation. Avoid repeated freezing and thawing of the product.ROX dye is used to correct the fluorescence signal error between the quantitative PCR wells, this product does not contain ROX dye, if you need to match the ROX dye with the instrument you are using, please contact your local business or call CombiSense customer service at 4006-222-360. PCR reaction system Attention: (1) Usually, the final primer concentration of 0.2 µM can get better results, and 0.1-1.0 µM can be used as a reference for setting the range. If the amplification efficiency is not high, the concentration of primer can be increased; if non-specific reaction occurs, the concentration of primer can be decreased to optimize the reaction system.(2) The final concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe to adjust the concentration.3) Because templates from different species contain different numbers of copies of the target gene, the template can be diluted in a gradient to determine the optimal amount of template to usePCR reaction conditionsmovetemptimingcirculatereverse transcription55°C1 min1premutability95°C10s1)1denaturation95°C1 s40-45Annealing/Extension55-60°C2)10-15s3)40-45Attention: (1) The enzyme used in this product is activated under the condition of pre-denaturation at 95℃ for 30s. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1min, so as to make the starting template fully unchained, and if the high temperature treatment time is too long, it will affect the activity of the enzyme; for simple templates, pre-denaturation time of 1-10s can also be used, and the optimal pre-denaturation time can be determined according to the template situation.(2) It is recommended to use two-step PCR reaction program, the annealing temperature should be 55-60℃ as the reference range, and the annealing temperature can be increased when non-specific reaction occurs. If you can't get good results due to the use of primers with low Tm values or long amplification products, you can try three-step PCR amplification.3) Whether the actual Real Time PCR instrument used supports rapid amplification cycles, please perform a pre-experiment to verify this for the first attempt... Read More | Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Product contentS666146Component50 T200 TStorageS666146ABuffer GR25 mL120 mLRTS666146BBuffer GL25 mL120 mLRTS666146CBuffer GW1 (concentrate)13 mL52 mLRTS666146DBuffer GW2 (concentrate)15 mL75 mLRTS666146EBuffer GE15 mL60 mLRTS666146FProteinase K1.25 mL4×1.25 mLRTS666146GSpin Columns DS with Collection Tubes50 sets 200 setsRTS666146HCentrifuge Tubes (1.5 mL)50 EA200 EARTProductsThis kit provides a simple and rapid method for the isolation and purification of total DNA from buccal swab samples. The kit adopts a silica matrix membrane that can specifically bind DNA and a unique buffer system to adsorb DNA efficiently and specifically, and 0.5-3.5 µg of genomic DNA can be obtained from each swab, and the extracted DNA fragments are large, pure and of stable and reliable quality. It is suitable for enzyme digestion, PCR, library construction, Southern hybridization and other experiments.Self-contained reagent: anhydrous ethanol.Pre-experiment Preparation and Important Notes1. Anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle before first use.2. If precipitation is found in Buffer GL before use, dissolve Buffer GL in a 56°C water bath.3. All centrifugation steps can be performed at room temperature.4. Sampling: Use a buccal swab to wipe the inside of the mouth 6 times, dry for 2 hours and store. To ensure that the sample is not contaminated by food or drink, do not eat or drink for 30 minutes before sampling.Procedure1. The swab of the buccal swab was cut from the rod with scissors and placed in a 2mL centrifuge tube (supplied) and 400µL Buffer GR was added.Note: For genomic DNA without RNA contamination, add 4 µL of RNase A solution at a concentration of 100 mg/ml and shake to mix.2. Add 20 µL of Proteinase K and 400 µL of Buffer GL, immediately vortex and shake for 15 seconds and mix thoroughly.Note: Mix well immediately after adding Buffer GL; do not add Proteinase K directly to Buffer GL for use.3.56°C for 10 minutes and centrifuge briefly so that the solution on the walls of the tube collects at the bottom.4. Add 400 µL of anhydrous ethanol, vortex and shake to mix thoroughly, and centrifuge briefly so that the solution on the wall of the tube collects at the bottom of the tube.Note: The addition of anhydrous ethanol may produce a white precipitate that will not affect subsequent experiments.5. Add the solution and precipitate obtained in the previous step to the Spin Columns DS in two batches of up to 700 µL at a time into the collection tube. centrifuge the column at 12,000 rpm (∼13,400 × g) for 1 minute, pour off the waste liquid from the collection tube, and return the column to the collection tube.6. Add 500 µL of Buffer GW1 to the adsorbent column (check that anhydrous ethanol has been added before use), centrifuge at 12,000 rpm for 1 minute, pour off the waste liquid in the collection tube, and put the adsorbent column back into the collection tube.7. Add 500 µL of Buffer GW2 to the adsorption column (check that anhydrous ethanol has been added before use), centrifuge the column at 12,000 rpm for 3 minutes, pour off the waste liquid in the collection tube, and put the column back into the collection tube.Note: Step 7 can be repeated if further DNA purity is required.8. Centrifuge at 12,000 rpm for 1 minute and pour off the waste liquid in the collection tube. Leave the adsorption column at room temperature for several minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.).9. Place the adsorption column in a new 1.5 mL centrifuge tube, add 50 µL of Buffer GE or sterilized water to the middle of the adsorption column overhanging the column, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm for 1 minute, collect the DNA solution, and store at -20℃.Attention:(1) If the downstream experiment is sensitive to pH or EDTA, it can be eluted with sterilized water. The pH value of the eluent has a great influence on the elution efficiency. If the eluent is made of water, the pH value should be 7.0-8.5 (the pH value of water can be adjusted to this range by using NaOH), and the elution efficiency is not high when the pH value is lower than 7.0.2) For long-term storage, it is recommended to elute with Buffer GE and store at -20°C... Read More |