| Description | Inquire | Format:2-ComponentEnzyme:Horseradish peroxidase | G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA G665573 Component 10 T Storage G665573A Buffer P1 30 mL RT G665573B Buffer P2 30 mL RT G665573C Buffer E3 30 mL RT G665573D Buffer PS 15 mL RT G665573E Buffer PW (concentrate) 10 mL RT G665573F Endo-Free Buffer EB 30 mL RT G665573G RNase A (10 mg/mL) 600 碌L RT G665573H Endo-Remover FX 10 EA RT G665573I Plungers 10 EA RT G665573J Spin Columns DX with Collection Tubes 10 EA RT G665573K Centrifuge Tubes (15 mL) 10 EA RTProduct IntroductionThis kit is specially designed for the efficient and rapid extraction of plasmids from 15-50 ml of bacterial fluids. On the basis of cell lysis by alkaline lysis method, it adopts unique silicon matrix membrane adsorption technology to bind plasmid DNA efficiently and exclusively, and each adsorption column can adsorb up to 250 µg of plasmid DNA; at the same time, it adopts a special buffer system and endotoxin removal filter to effectively remove endotoxin, genomic DNA, RNA, protein and other impurities. The plasmids obtained from this kit are of high purity and stable quality, and can be used for cell transfection, as well as DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self-contained reagents: anhydrous ethanol, isopropanol.Pre-experiment Preparation and Important Notes1. All components are stable for 1 year in a dry, room temperature (15-30°C) environment, and longer by placing the adsorption columns at 2-8°C. Buffer P1 with RNase A is stable for 6 months at 2-8°C.2. Before the first use, add all of the RNase A solution to Buffer P1, mix well, and store at 2-8°C. Before use, it needs to be left at room temperature for a period of time, return to room temperature and then use.3. Anhydrous ethanol should be added to Buffer PW before the first use according to the instructions on the reagent bottle label.4. Please check Buffer P2 and Buffer E3 for crystallization or precipitation before use. If there is any crystallization or precipitation, the clarification can be restored by taking a water bath at 37℃ for a few minutes.5. Be careful not to touch Buffer P2 and Buffer E3 directly, and tighten the lid immediately after use.6. The amount and purity of extracted plasmid is related to the concentration of bacterial culture, strain type, plasmid size, plasmid copy number and other factors.7. The adsorption columns treated with Buffer PS should be used immediately to avoid leaving them for too long.Operation steps1.Take 15-50 ml of fresh bacterial solution from the overnight culture, add it to a centrifuge tube (self-prepared) and centrifuge at 5000 × g for 10 minutes to collect the bacteria, and aspirate all the supernatant as much as possible.2.Add 2.5 ml of Buffer P1 to the centrifuge tube in which the bacterial precipitate has been left (please check that RNase A has been added first) and suspend the bacterial precipitate by mixing thoroughly using a pipette or vortex shaker. Note: If the bacterial mass is not thoroughly mixed, it will affect the lysis effect and make the extraction amount and purity low.3.Add 2.5 ml of Buffer P2 to the centrifuge tube, mix gently up and down 8-10 times to fully lyse the organisms, and leave at room temperature for 3-5 minutes. At this point the solution should become clear and viscous. Note: Mix gently, do not shake vigorously, so as not to interrupt the genomic DNA and cause genomic DNA fragments to be mixed in the extracted plasmid. If the solution does not become clear, it suggests that the amount of bacteria may be too large and the lysis is not complete, and the amount of bacteria should be reduced.4.Add 2.5 ml of Buffer E3 to the centrifuge tube and mix immediately by turning up and down 8-10 times, at which time a white flocculent precipitate appears. Note: Buffer E3 should be mixed immediately after addition to avoid localized precipitation.5.Install the cap of the filter (Endo-Remover FX), transfer the solution obtained in step 4 to the filter, wait until the white flocculent precipitate floats on the upper layer of the solution, remove the cap of the filter, align the filter with a clean 15 ml centrifuge tube (supplied), and slowly push the handle (Plungers) to filter, so that as much as possible of the solution passes through, and the filtrate is collected in the centrifuge tube.6.Add 1/3 solution volume of isopropanol to the filtrate and mix upside down.7.Column Equilibrium: Add 1ml Buffer PS to the adsorption column (Spin Columns DX) that has been loaded into a 15ml centrifuge tube, centrifuge for 2 minutes at 2500 x g. Pour off the waste liquid from the centrifuge tube and put the adsorption column back into the centrifuge tube.8.The mixture of filtrate and isopropanol from step 6 was transferred to the equilibrated adsorption column (which had been loaded into a collection tube).9.Centrifuge at 2500 x g for 1 minute, pour off the waste solution in the collection tube and put the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 4 ml, so the solution obtained in step 8 is passed through the column in 2 times.10.Add 2 ml of Buffer PW to the adsorption column (please check that anhydrous ethanol has been added first), centrifuge at 2500 × g for 1 min, and pour off the waste liquid in the collection tube.11.Repeat step 10.12.The adsorbent column was put back into the collection tube and centrifuged at 2500 × g for 2 min, the waste liquid was poured off, and the column was left to dry at room temperature for 5 min.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with subsequent enzymatic reactions (digestion, PCR, etc.)13. Place the adsorption column in a new 15 ml centrifuge tube, add 0.5-1 ml Endo-Free Buffer EB to the middle of the adsorbent membrane, leave it at room temperature for 2-5 minutes, centrifuge it at 2500 × g for 2 minutes, and collect the plasmid solution into the centrifuge tube. -20°C to store the plasmid.Note: 1) In order to increase the recovery efficiency of the plasmid, the obtained solution can be reintroduced into the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 2500 x g for 2 minutes, and the plasmid solution can be collected into a centrifuge tube.2) When the plasmid copy number is low or >10kb, Endo-Free Buffer EB can increase the extraction efficiency by preheating at 65-70°C in a water bath... Read More | The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of The miRNA extraction kit is specifically designed to isolate and purify miRNAs from various animal tissues, plant tissues, cells, serum, plasma and other samples. It can also extract small molecule RNAs such as siRNA and snRNA that are less than 200 nt, and can also be used for the extraction of total RNA. This product combines phenol/guanidine lysis technology and silicon matrix membrane purification technology. The unique lysis solution can effectively inhibit RNases while removing most of DNA and proteins from cell or tissue samples through organic extraction. For some sensitive downstream experiments, if miRNA enrichment is required, this kit can be used to enrich miRNA separately. This product is suitable for a wide range of samples, with high purity of prepared RNA, and can be directly used for sensitive downstream applications, such as Northern Blot analysis, Real Time PCR, Microarray Analysis, etc. M665531Component50 TStorageM665531ATRIzon Reagent60 mL2-8℃. Protect from ligt.M665531BBuffer RWT (concentrate)15 mLRTM665531CBuffer RW2 (concentrate)11 mLRTM665531DRNase-Free Water10 mLRTM665531ESpin Columns RM with Collection Tubes50 setsRTM665531FSpin Columns RS with Collection Tubes50 setsRTM665531GRNase-Free Centrifuge Tubes (1.5 mL)50 EART Self prepared reagents: chloroform, anhydrous ethanol (newly opened or dedicated for RNA extraction).Preparation and important precautions before the experiment:To prevent RNase pollution, attention should be paid to the following aspects:1) Use RNase free plastic products and gun heads to avoid cross contamination.2) Glassware should be dry baked at a high temperature of 180 ℃ for 4 hours before use, while plastic containers can be soaked in 0.5 M NaOH for 10 minutes, thoroughly rinsed with water, and then sterilized under high pressure.3) Prepare the solution using water without RNase.4) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The extracted samples should avoid repeated freeze-thaw cycles, otherwise it will affect the quantity and quality of miRNA extraction.Before the first use, anhydrous ethanol should be added to Buffer RWT and Buffer RW2 according to the instructions on the reagent bottle label.4. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Operation steps:Protocol A: miRNA enrichment (can be directly used for sensitive downstream experiments)1. Sample processing1a Organization: Grind the organization in liquid nitrogen. Add 1 ml of TRIzon Reagent to every 30-50 mg of tissue, shake and mix well. The sample volume shall not exceed one tenth of the volume of TRIzon Reagent.1b Single layer culture of cells: Remove the culture medium, add TRIzon Reagent, and add 1 ml of TRIzon Reagent every 10 cm2 (the amount of lysis solution depends on the area of the culture bottle).1c Cell suspension: Centrifuge to obtain cell precipitate, discard supernatant. Add 1 ml of TRIzon Reagent to every 5 x 106-1 x 107 cells (cells do not require washing).1d Plasma or serum: Take 200 µ Add 5 times the volume of TRIzon Reagent to plasma or serum samples, shake and mix well for 30 seconds.2. After adding TRIzon Reagent to the sample, blow it repeatedly several times to fully crack it. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Optional steps: Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 5 minutes, take the supernatant, and transfer it to a new centrifuge tube (provided by oneself) (if the sample contains more proteins, fats, polysaccharides, etc., this step can be performed).4. Add chloroform to the supernatant and add 200 to every 1 ml of TRIzon Reagent used µ Chloroform, cover the tube, vigorously shake for 15 seconds, and let it sit at room temperature for 5 minutes.Centrifuge at 5.4 ℃ and 12000 rpm for 15 minutes. The sample is divided into three layers: red organic phase, middle layer, and colorless aqueous phase. Transfer the upper colorless aqueous phase to a new centrifuge tube (self prepared).6. Add 1/3 volume of anhydrous ethanol to the solution obtained in step 5, mix well, and transfer the obtained solution and precipitate together into the adsorption column RM (Spin Columns RM) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the adsorption column RM after centrifugation, and retain the effluent.7. Add 2/3 times the volume of anhydrous ethanol to the solution obtained in step 6 and mix well.8. Transfer the solution and precipitate obtained from the previous step into the adsorption column RS (Spin Columns RS) that has been loaded into the collection tube. If you cannot add all the solution to the adsorption column at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.9. Add 700 to the adsorption column RS µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.10. Add 500 to the adsorption column RS µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RS back into the collection tube.11. Repeat step 10.12. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RS at room temperature for a few minutes to thoroughly air dry. Note: The purpose of this step is to remove residual ethanol from the adsorption column RS, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).13. Place the adsorption column RS in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 13 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RS and repeat step 13Protocol B: Extraction of total RNA (including miRNA and other small molecule RNAs<200 nt), steps 1-5 are the same as protocol A.6. Add 1.25 times the volume of anhydrous ethanol to the solution obtained in step 5 and mix well.7. Transfer the solution and precipitate obtained from the previous step into the spin columns RM that have been loaded into the collection tube. If you cannot add all the solution to the adsorption column RM at once, please transfer it multiple times. Centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.8. Add 700 to the adsorption column RM µ L Buffer RWT (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.9. Add 500 to the adsorption column RM µ Buffer RW2 (check if anhydrous ethanol is added before use), centrifuge at 12000 rpm for 30 seconds, discard the waste liquid in the collection tube, and place the adsorption column RM back into the collection tube.10. Repeat step 9.11. Centrifuge at 12000 rpm for 1 minute and discard the waste liquid from the collection tube. Place the adsorption column RM at room temperature for a few minutes to thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column RM, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Transfer the adsorption column RM into a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store the obtained RNA solution at -70 ℃ to prevent degradation. Attention: 1) The volume of RNase Free Water should not be less than 30 µ l. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 12 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column RM and repeat step 12... Read More | DescriptionMaterials included in the kit are designed to be used with the Hy-Energy′s PCTPro-2000 System. They also can be used for demonstration purposes and as standards during the development of novel hydrogen storage and battery materials |